3
Failures / Errors
GB012 - 25K
26
3.5
Electrical Datas
Description
Supply Voltage
Value
Tolerance
Remarks
Termperature Limiter
Pramiary HE
24 VDC
0 Ohm
-
Temp. Limit = 110 ºC
Termperature Limiter
(Recuperator-Flue gas)
24 VDC
0 Ohm
-
Temp. Limit = 100 ºC
DHW Temp. Sensor
(NTC)
5 VDC
20 ºC => 12,4 kOhm
60 ºC => 2,5 kOhm
± 0,5 kOhm
--
Flow Temp. Sensor
(NTC)
5 VDC
20 ºC => 14,8 kOhm
60 ºC => 3,2 kOhm
± 0,5 kOhm
see resistance table
Flue gas safety (Com-
bustion chamber ) Sen-
sor (NTC, behind
burner)
5 VDC
20 ºC => 12,1 kOhm
60 ºC => 2,9 kOhm
± 0,5 kOhm
---
Pump
230 VAC
I = 495 Ohm
II = 355 Ohm
III = 220 Ohm
± 10 Ohm
---
Ionisation Electrode
--
ca. 3 - 5 µA
-
Gas Safety Valve 1
230 VAC
1,55 kOhm
± 10 Ohm
Gas Safety Valve 2
230 VAC
8 kOhm
± 20 Ohm
common (neutral)
(black cable)
Gas Regulator
0 - 24 VDC
ca. 80 Ohm
min. 25 mA
max. 130 (LPG
165)mA
± 5 Ohm
Fan
230 VAC
38 Ohm
± 5 Ohm
Fan Sensor
1. Vcc = 5VDC (supply)
2. GND (-)
3. Vout (Signal) 5 VDC
check physical
-
---
2 ad. Fuse T 1,6 A,
230 VAC (L + N.)
230 VAC
0 Ohm
-
Cut supply !
Water level switch
24 VDC
300 kOhm
(during operation)
In case of short circuit
: < 300 kOhm.
Water Flow Rate Sen-
sor (Turbine)
1 = “-” 0 VDC
2 = Signal 0-5 VDC
3 = “+” 5 VDC
9,6 Hz = 1,5 l/dk.
68,7 Hz = 10 l/dk.
± 2 Hz
± 6 Hz
Can measured in Hz
between 1. and 2.
cable.
Tab. 8