Installation (for engineers only)
Logamatic SC40 - Technical specifications are subject to change without prior notice.
36
4
4.4.24
Configuration diagram S1 - swimming pool connected via valve
Fig. 30
R1
Solar circuit pump 1
R2
Heat exchanger pump
R3
Daily heating pump (optional)
R4
Cylinder selection valve
R5
Anti-icing system valve (optional)
S1
Collector temperature sensor FSK
S2
Cylinder bottom temperature sensor
S3
Swimming pool temperature sensor
S4
Cylinder centre temperature sensor (optional)
S6
Temperature sensor for external heat exchanger
S7
Flow heat meter WMZ temperature sensor (optional)
S8
Return heat meter temperature sensor (optional)
WMZ
Heat meter (optional)
WMZ
5
R1
S2
S3
S8
S7
R5
S1
R4
R2
S6
S4
R3
7747006072-19.1 SD
S1 S2 S3 S4 S5 S6 S7 S8
I9
L
N
R1 N1 R2 N2 R3 R3 R4 R4 R5 R5
L3 N3 L4 N4 L5 N5
230V
AC
R4
R3
R5
R2
R1
S1 S2 S3 S4
S6 S7 S8 WMZ