5
Installation
Logalux LT160/1 | LT200/1 | LT300/1 – 6 720 811 745 (2021/10)
10
5
Installation
The tank is delivered fully assembled.
▶ Check that the tank is complete and undamaged.
5.1
Tank installation
5.1.1
Requirements for installation location
▶ Place the DHW tank on a plinth if there is a risk that water may collect
at the installation site.
▶ The installation site must be a dry and frost-free room.
▶ Observe minimum wall clearances at installation location (
▶ Maintain a clearance of 2" (51 mm) from heated pipes and
combustible surfaces.
5.1.2
Wall clearances
Fig. 6
Recommended minimum wall clearances (illustrative)
5.1.3
Positioning the tank
▶ Cut the packaging film on the side opposite the "Tank top" sticker
(
Fig. 7).
▶ Remove only the film you have cut out.
▶ Thread the 4 adjustable feet supplied [1] ~ 0.6...1 inch into the
threaded bushings provided for this purpose.
▶ Remove the wooden corner strips [3] from the tank underside.
Fig. 7
Cutting the packaging film and inserting the adjustable feet
[1]
Adjustable feet
[2]
Rear end of tank
[3]
Wooden corner strips
[4]
Front end of tank
▶ Tip the DHW tank over on the edge of the pallet and set it on its feet
(
Fig. 8).
▶ Remove the remaining film, bottom and top of packaging and
wooden pallet. Raise the front and rear of the DHW tank slightly if
necessary to do this.
The material for positioning and fastening the floor-
standing boiler to the DHW tank is included in the scope
of delivery of the boiler-storage tank connecting line.
NOTICE:
Risk of damage from inadequate load-bearing
capacity of the supporting substructure or unsuitable
floor surface!
▶ Ensure that the installation area is level and offers
sufficient load-bearing capacity.
NOTICE:
Risk of damage from stress cracking and
corrosion!
▶ Position the DHW tank in a dry room free from the
risk of freezing.
▶ Install the tank only in closed-loop, unvented
hydronic heating systems.
▶ Never use open, vented expansion vessels for this
DHW tank.
NOTICE:
If leaks can result in property damage or a drain
pan is required by law:
▶ Install an adequate drain pan.
▶ Follow the installation instructions of the drain pan
manufacturer.
6 720 810 502-01.1T
min 16 in.
min 26 in.
A
1
4
2
6 720 810 502-02.1T
3