7
Appendix
Logano plus – 6720865368 (2019/05)
9
7
Appendix
7.1
Product data for energy consumption
The following product data satisfy the requirements of the EU Regulations No. 811/2013, No. 812/2013, No. 813/2013 and No. 814/2013
supplementing Directive 2010/30/EU.
Table 3 Product data for energy consumption
7.2
Environmental protection/disposal
Environmental protection is a fundamental corporate strategy of the
Bosch Group.
The quality of our products, their economy and environmental safety are
all of equal importance to us and all environmental protection legislation
and regulations are strictly observed.
We use the best possible technology and materials for protecting the
environment taking account of economic considerations.
Packaging
Where packaging is concerned, we participate in country-specific
recycling processes that ensure optimum recycling.
All of our packaging materials are environmentally compatible and can be
recycled.
Used appliances
Used appliances contain valuable materials that can be recycled.
The various assemblies can be easily dismantled. Synthetic materials are
marked accordingly. Assemblies can therefore be sorted by composition
and passed on for recycling or disposal.
Used electrical and electronic appliances
Electrical or electronic devices that are no longer
serviceable must be collected separately and sent for
environmentally compatible recycling (in accordance with
the European Waste Electrical and Electronic Equipment
Directive).
To dispose of old electrical or electronic devices, you
should use the return and collection systems put in place in the country
concerned.
Batteries must not be disposed together with your household waste.
Used batteries must be disposed of in local collection systems.
Gas type
G20
8732923571
Gas type
G25
8732923664
Product data
Symbol
Unit
Product type
–
–
GB402-395
Floor standing condensing boiler
–
–
Yes
Specified heat output
P
rated
kW
367
Available heat output
At rated heat output and high temperature regime
1)
1) High-temperature operation means a return temperature of 60 °C at the boiler inlet, and a flow temperature of 80 °C at the boiler outlet.
P
4
kW
367.4
At 30 % of rated output and low-temperature operation
2)
2) Low-temperature operation means a return temperature (at the boiler inlet) of 30 °C for floor standing condensing boilers, of 37 °C for floor standing boilers, and 50 °C for
other boilers
P
1
kW
121.8
Useful efficiency
At rated heat output and high temperature regime
4
%
88.7
At 30 % of rated output and low-temperature operation
1
%
97.2
Auxiliary electricity consumption
At full load
el
max
kW
0.449
At part load
el
min
kW
0.045
On standby
P
SB
kW
0.005
Other items
Standby heat loss
P
stby
kW
0.828
NOx emissions
NOx
mg/kWh
36