Product information
SU120.5 | SU160.5 | SU200.5 | SU200.5 E – 6 720 819 283 (2016/04)
36
2.4
Specification
2.5
Product datasheet on energy consumption
The following product data complies with the requirements of EU Regulations 811/2013 and 812/2013 as supplement to the Directive 2010/30/EU.
Unit
SU120.5
SU160.5
SU200.5
SU200.5 E
General data
Dimensions
Height when tilted
mm
1160
1410
1625
1625
Minimum room height for anode replacement
mm
1370
1650
1880
1880
Connections
Connection size, DHW
DN
R1"
R1"
R1"
R1"
Connection size, cold water
DN
R1"
R1"
R1"
R1"
Connection size, DHW circulation
DN
R¾ "
R¾ "
R¾ "
R¾ "
Internal diameter, test port, cylinder temperature sensor
mm
19
19
19
19
Weight (dry, excl. packaging)
kg
64
74
84
84
Total weight when filled
kg
184
234
284
284
Cylinder capacity
Available capacity (total)
l
120
160
200
200
Available amount of DHW
1)
DHW outlet temperature
2)
:
1) Without solar heating or reheating; selected cylinder temperature 60 °C
2) Mixed water at the draw-off point (at 10 °C cold water temperature)
45 °C
l
163
217
271
271
40 °C
l
190
253
317
317
Standby heat loss to DIN 4753 part 8
3)
3) Distribution losses outside the buffer cylinder are not taken into account.
kWh/24h
1,4
1,8
2,0
2,0
Maximum throughput, cold water inlet
l/min
12
16
20
20
Maximum DHW temperature
°C
95
95
95
95
Max. operating pressure, DHW
bar (positive)
10
10
10
10
Highest design pressure (cold water)
bar (positive)
7,8
7,8
7,8
7,8
Maximum DHW test pressure
bar (positive)
10
10
10
10
Indirect coil
Contents
l
4,8
6,0
6,0
6,0
Surface area
m
2
0,7
0,9
0,9
0,9
Performance factor N
L
to DIN 4708
4)
4) The performance factor N L=1 to DIN 4708 for 3, 5 occupants, standard bath tub and kitchen sink. Temperatures: cylinder 60 °C, outlet 45 °C and cold water 10 °C.
Measured at max. heat input. The N
L
drops with reduced heat input.
N
L
1,4
2,6
4,2
4,2
Continuous output (at 80 °C flow temperature, 45 °C DHW outlet
temperature and 10 °C cold water temperature)
kW
l/min
25
10,2
31,5
12,9
31,5
12,9
31,5
12,9
Heat-up time at rated output
min
19
20
25
25
Max. heating with E-heating system, only for SU200.5 E
5)
5) Limit to the stated value for heat sources with higher heat input.
kW
-
-
-
6
Maximum heating water temperature
°C
160
160
160
160
Max. heating water operating pressure
bar (positive)
16
16
16
16
Connection size, heating water
DN
R1"
R1"
R1"
R1"
Pressure loss diagram
Table 4 Dimensions and specification (
Fig. 1, page 59 and Fig. 3, page 60)
Product number
Product typ
Storage volume (V)
Standing loss (S)
Water heating energy efficiency class
7 735 500 669
8 718 542 331
8 718 543 049
SU120.5
SU120/5
SU120/5W
116,7 l
38,0 W
B
7 735 500 670
8 718 542 280
8 718 543 058
SU160.5
SU160/5
SU160/5W
156,9 l
45,8 W
B
7 735 500 671
8 718 542 326
8 718 543 067
SU200.5
SU200/5
SU200/5W
198,5 l
55,0 W
B
7 735 500 672
8 718 543 077
8 718 543 078
SU200.5 E
SU200/5E
SU200/5EW
198,5 l
55,0 W
B
Table 5 Product datasheet on energy consumption
Содержание 7 735 500 669
Страница 1: ......
Страница 9: ...9 SU120 5 SU160 5 SU200 5 SU200 5 E 6 720 819 283 2016 04 8 9 2 3 19 65 15 64 20 24 65 15 mm...
Страница 34: ...9 SU120 5 SU160 5 SU200 5 SU200 5 E 6 720 819 283 2016 04 33 9 2 3 19 65 15 64 20 24 65 15 mm...
Страница 68: ...SU120 5 SU160 5 SU200 5 SU200 5 E 6 720 819 283 2016 04 67...
Страница 69: ...Bosch Thermotechnik GmbH Sophienstrasse 30 32 D 35576 Wetzlar www buderus com...
Страница 70: ......