Installation
1
8
Installation and maintenance instructions for Buderus 500 - 24/S • 08/2006
Buderus • http://www.buderus-domestic.co.uk
Subject to modifications resulting from technical improvements!
Flue gas values
Condensate water quantity, natural gas, 40/30
°
C
l/h
1.6
Exhaust-fume mass-flow rate
Full load
Part-load
g/s
g/s
10.6
4.3
Exhaust-fume temperature, full load
Heating curve 75/60
°
C
Heating curve 40/30 °C
°C
°C
77
55
Exhaust-fume temperature, partial load
Heating curve 75/60
°
C
Heating curve 40/30 °C
°C
°C
60
35
CO
2
full load, natural gas
standard test gas G20
%
9.2
CO
2
full load, natural gas
standard test gas LPG
%
10.3
Standard emission factor CO
mg/kWh
<22
Standard emission factor NO
x
mg/kWh
<30
Flow pressure available for use
Pa
75
Flue-gas system
Type of exhaust-fume connection
C
13(X)
, C
33(X)
, C
53(X),
C
73(X)
Diameter of flue gas system
mm
60/100 (accessory)
Electrical data
Mains connection voltage
V
230 (50 Hz)
Electrical power consumption
Full/Partial load
W
110/88
Electrical protection rating
IP X4D
Boiler dimensions and weight
Height x Width x Depth
mm
780 x 460 x 330
Weight (without casing)
kg
31
Casing
kg
3
Dimensions
Unit
500 Series wall-mounted condensing gas
system boiler
500 - 24/S