1
1
The following table shows the approximate outputs of each appliance based on a 45 minute
re-fuelling cycle burning seasoned hardwood logs.
Note that the minimum chimney vacuum will allow the fire to be started, for full output
use, the chimney vacuum will need to be at the max reading.
STOVES
WATER SPACE HEIGHT WIDTH DEPTH
FLUE
DIA
FLUE
OPTIONS
INS FLUE
VACUUM
WEIGHT
kg
CORNER
1-4KW
514
545
305
100
TOP ONLY
.03"MIN TO
.08"MAX
50
WET VERSION
1-3KW
1-2KW
514
545
305
100
TOP ONLY
.03"MIN TO
.08"MAX
60
4B
1-5KW
495
442
317
100
TOP-REAR
.03"MIN TO
.08"MAX
60
WET VERSION
1-3KW
1-2KW
495
442
317
100
TOP-REAR
.03"MIN TO
.08"MAX
70
3B
1-3KW
486
440
317
125
TOP-REAR
.03"MIN TO
.08"MAX
50
WET VERSION
1-2KW
1KW
486
440
317
125
TOP-REAR
.03"MIN TO
.08"MAX
50
7B
2-8KW
590
595
342
125
TOP-REAR
.03"MIN TO
.1"MAX
80
SMALL BOILER
1-3KW
1-4KW
590
595
342
125
TOP-REAR
.03"MIN TO
.1"MAX
90
LARGE BOILER
2-8KW
1-3KW
590
595
342
125
TOP-REAR
.03"MIN TO
.1"MAX
120
OVEN STOVES
CORNER POD
1-4KW
817
545
305
100
TOP ONLY
.03"MIN TO
.08"MAX
90
WET VERSION
1-3KW
1-2KW
817
545
305
100
TOP ONLY
.03"MIN TO
.08"MAX
105
4BPOD
1-5KW
850
442
317
100
TOP ONLY
.03"MIN TO
.08"MAX
100
WET VERSION
1-2KW
1-3KW
850
442
317
100
TOP ONLY
.03"MIN TO
.08"MAX
115
7BPOD
2-8KW
1050
595
480
125
TOP-REAR
.03"MIN TO
.1"MAX
130
SMALL BOILER
1-3KW
1-4KW
1050
595
480
125
TOP-REAR
.03"MIN TO
.1"MAX
140
LARGE BOILER
2-8KW
1-3KW
1050
595
480
125
TOP-REAR
.03"MIN TO
.1"MAX
150
MINI COOKER
1-3KW
500
550
385
100
TOP ONLY
03"MIN TO
.08"MAX
120
WET VERSION
1KW
1-2KW
500
550
385
100
TOP ONLY
03"MIN TO
.08"MAX
125