Bubble 2 Rayburn Regent Скачать руководство пользователя страница 8

 

Occasionally scrape away any hard carbon deposits from the bottom of the burner pot. 

5

5

 

 

E

E

X

X

T

T

I

I

N

N

G

G

U

U

I

I

S

S

H

H

I

I

N

N

G

G

 

 

Shutting the burner off is a very simple manoeuvre. 

Turn the oil flow control knob FULLY in a clockwise direction until you feel it stop in its off 
position. 

After a few minutes, the flame will die down and eventually extinguish itself. 

DO NOT TOUCH THE STOVE UNTIL IT HAS COMPLETELY COOLED DOWN. 

NEVER TRY TO RE LIGHT A HOT BURNER, MAKE SURE THAT THE BURNER IS 
COMPLETELY COOLED DOWN BEFORE RE LIGHTING. 

6

6

 

 

F

F

U

U

E

E

L

L

 

 

S

S

U

U

P

P

P

P

L

L

Y

Y

 

 

I

I

N

N

F

F

O

O

R

R

M

M

A

A

T

T

I

I

O

O

N

N

 

 

Your Fuel is stored in an oil tank, which should incorporate the following features. 

1.  1 A fuel gauge, which can be in the form of a numbered circular dial or a site glass into 

which oil is fed so as to indicate the amount of oil in the tank. 

2.  2 A manually operated isolation valve on the tank, usually a gate valve. 

3.  3 A fuel filter to filter out any small particles of dirt or contamination, which may get into 

the oil or tank. 

4.  4 An automatically operated safety valve designed to shut off the oil supply should a fire 

occur near to the stove. 

5.  5 A manually operated isolation valve near to the stove to allow you or the service man 

to turn the oil off should the need arise. 

If you allow the stove to run the oil tank dry it will obviously go out. 

Before filling the fuel tank you must make sure that the oil valve is tripped to it’s off position, 
otherwise the pot will flood. 

If the pot floods do not attempt to light the stove until the excess oil has been removed from it. 

7

7

 

 

T

T

H

H

E

E

 

 

C

C

O

O

A

A

L

L

 

 

K

K

I

I

T

T

 

 

The coals are located on the coal support bars, which are designed to glow red in the flame, 
passing on the incandescence into the coals. 

Care must be taken when positioning the coals on the spikes. 

Do not fit any extra coals, as this will invalidate the product warranty. 

The whole system is designed so that it can be removed in its entirety without the need to disturb 
the coals making routine cleaning and servicing very easy. 

To remove it turn the stove off and when it is cooled down, undo the front door knob, open the 
door and carefully lift it out, using the front fret. 

The coal support bars and coals may need replacing from time to time and they are available 
from your supplier as a service item. 

Take care not to drop any coals into the pot. 

Содержание 2 Rayburn Regent

Страница 1: ...B BU UB BB BL LE E 2 2 W WE ET T I IN NS SE ET T S ST TO OV VE E U US SE ER R I IN NS ST TR RU UC CT TI IO ON NS S I IS SS SU UE E 3 3 Mk 2 Stove 25 01 03 http www oilstoves co uk...

Страница 2: ...___________________________________________________ 9 Every 4 Weeks______________________________________________________________ 9 Every 8 Weeks_______________________________________________________...

Страница 3: ...ve must be treated in the same way as a SOLID FUEL APPLIANCE and as such whilst it is running some parts of it will become hot and must not be touched Fireguards must be fitted and only British Standa...

Страница 4: ...thus automatically shutting off the oil supply into the stove If item 1 has caused a shut down you will have to wait for the water temperature to drop before you will be able to reset the valve If ite...

Страница 5: ...p you may find the first option easier as you can see the oil trickle in to the pot more easily You must use a heatproof glove when putting the catalysers back into the pot and it is important to repl...

Страница 6: ...lue flame combustion 15 Allow the burner to run for a further 10 minutes before turning the appliance up to the higher settings 16 If at any time during the ignition process large amounts of flame can...

Страница 7: ...nd coals NEVER TRY TO RELIGHT A HOT BURNER MAKE SURE THAT THE BURNER IS COMPLETELY COOLED DOWN BEFORE RE LIGHTING 4 4 G GL LA AS SS S A AN ND D S ST TO OV VE E C CL LE EA AN NI IN NG G The door glass...

Страница 8: ...o shut off the oil supply should a fire occur near to the stove 5 5 A manually operated isolation valve near to the stove to allow you or the service man to turn the oil off should the need arise If y...

Страница 9: ...ontinuous running time of the stove Lightly clean the inside of the door glass using dry cloth Do not attempt to clean the glass whilst it is hot or warm This will cause the glass to craze or crack E...

Страница 10: ...ar will occur to the catalysers and burner if the appliance is subjected to conditions of continuous or intermittent high flue vacuum B BU UR RN NE ER R S SH HU UT TS S D DO OW WN N A AN ND D S ST TO...

Страница 11: ...vice o Oil control valve is faulty Unlikely O OI IL L S SM ME EL LL LS S Generally slight oil leaks in the appliance may only be noticed when the appliance is turned off as the oil vapour will normall...

Страница 12: ...r hour If your oil costs more or less than 20 pence work out the difference as a percentage and apply it to the 20 pence for a corrected figure WET STOVES large boiler Minimum firing Maximum firing B2...

Страница 13: ...HEAT SHIELD RIGHT SIDE LIGHTING PORT COVER...

Отзывы: