Operating
- 3.32 -
SMART 3000TW
And so on until:
At this point the logical configuration is completed:
We have defined:
-
4 sections (Sides A, B, C, D)
-
10 columns per section
-
8 sensors per columns
corresponding to a total number of 320 sensors.
Now, assuming that the machine is configured with 2 Boards.
Board 01 = 160 sensors [SIDE A + SIDE B]
Board 02 = 160 sensors [SIDE C + SIDE D]
In case of failure on sensor #254, the error signalling message will be displayed as:
SIDE D COL 02.
!
In the above example, we assumed that the machine had 4 identical sections
(80 sensor per section). However, the SMART 3000TW system allows you to
configure the sections differently from each other.
DEFINE
COL
01
L 0241
H
0248
L 0313
H
0320
1
st
column of
Section D