background image

24

4 Advanced configuration

4.1 

Connection to the PC

To  transfer  the  configuration  performed  using  the  TiSferaDesign  software,  or  to  update  the 
firmware, connect the Sfera Proximity Reader to the PC using a USB-miniUSB cable.

miniuSB - uSB

BuS

When updating the software the device must be powered.

The Sfera Proximity Reader connected using an USB cable is recognised by the PC as a virtual port 
(VIRTUAL COM).

Содержание Sfera video kit

Страница 1: ...353200 Sfera Proximity Reader Installer manual 07 12 01 PC ...

Страница 2: ...2 ...

Страница 3: ...er master badge 10 3 2 Passepartout badge 11 3 2 1 New passepartout badge 11 3 2 2 Deleting passepartout badges 13 3 3 Resident badge 14 3 3 1 New resident badge M 00 14 3 3 2 Deleting resident badges M 00 16 3 3 3 New apartment master badge M 01 18 3 3 4 Deleting the apartment master badge M 01 20 3 3 5 New resident badge M 01 21 3 3 6 Deleting resident badges M 01 23 4 Advanced configuration 24 ...

Страница 4: ...s manual very carefully The warranty will automatically become void in case of negligence improper use and tampering by unauthorised personnel The Sfera Proximity Reader must only be used with BTicino 2 wire digital systems Front covers that may be used with the Sfera BTicino Proximity reader Front cover 353205 Front cover 353201 02 03 ...

Страница 5: ...r 2 2 Once the badges have been saved in the reader opening of the door lock will be possible Four types of badges may be programmed MANAGER MASTER Badge providing access to the programming of other codes It can only be used for programming not for access APARTMENT MASTER Once the apartment badge has been defined this can be used to program the badges of the resident of that apartment It can only ...

Страница 6: ... 2 2 Front view 1 Programming reset pushbutton 2 Mini USB programming connector 3 Red LED on steady access denied or programming error 4 Green LED on steady access granted or programming successful 5 Antenna 1 2 3 4 5 ...

Страница 7: ...nection to the door lock CP P1 and tamper CP P2 future application pushbutton 2 Local relay contacts 3 Connection to the BUS 4 Connector for the connection to subsequent modules 5 Connector for the connection to previous modules 6 Configurator sockets 3 2 1 5 4 6 ...

Страница 8: ... signals and the switching on of the green LED The transmission of an unrecognised badge or a programming error e g memory full or badge already used will cause the interruption of the programming procedure This interruption is con firmed by a long beep and the red LED coming on 3 1 1 New manager master badge 1 Press and hold down the programming pushbutton until the green LED starts flashing and ...

Страница 9: ...imity Reader is ready for normal operation The programming sequence must start within 30 seconds from the moment the pro gramming key has been pressed and must be carried out in one stage 5 Press the pushbutton or wait 30 seconds to exit the procedure 4 It is possible to continue to enter further manager master badges max 20 one after the other Manager master ...

Страница 10: ... master badges To stop the deletion procedure release the programming pushbutton before the extended beep see item 2 To only delete a specific badge use the TiSferaDesign software 2 Continue holding down the pushbutton the device emits 1 beep per second and a long beep after ten seconds 3 The red LED flashes and then switches off to confirm that the deletion has been performed ...

Страница 11: ...on of an unrecognised badge or a program ming error e g memory full or badge already used will cause the interruption of the program ming procedure This interruption is confirmed by a long beep and the red LED coming on 3 2 1 New passepartout badge 2 Move a new passepartout badge near the reader to save it 1 Place a manager master badge close to the reader the reader emits a short beep and the gre...

Страница 12: ...t beep and the switching off of the LED confirm that the programming sequence has been completed The Sfera Proximity Reader is ready for normal operation 5 Press the pushbutton or wait 30 seconds to exit the procedure 4 It is possible to continue to program further passepartout badges max 100 one after the other Pass ...

Страница 13: ...der The device emits a beep and the green LED starts flashing Repeat the operation three times in succession The procedure will delete all the saved passpartout and apartment master badges To only delete a specific badge use the TiSferaDesign software Three times Manager master 3 The red LED flashes and then switches off to confirm that the deletion has been performed ...

Страница 14: ...ignals and the switching on of the green LED The transmission of an unrecognised badge or a programming error e g memory full or badge already used will cause the interruption of the pro gramming procedure This interruption is confirmed by a long beep and the red LED coming on 3 3 1 New resident badge M 00 M 00 managing residents using the manager master 1 Place a manager master badge close to the...

Страница 15: ...edure The programming sequence must start within 30 seconds and must be carried out in one stage 3 Move a new resident badge near the reader to save it 4 The flashing of the green LED and a short beep confirm that the resident badge has been saved A short beep and the switching off of the LED confirm that the programming sequence has been completed The Sfera Proximity Reader is ready for normal op...

Страница 16: ... The device emits a beep and the green LED starts flashing 2 Using the key module 352000 352100 or the display 352500 select the apartment from which the resident badges must be eliminated the reader will emit a beep to confirm 352500 Manager master M 00 managing residents using the manager master ...

Страница 17: ...o confirm that it has been cancelled The procedure will delete all the stored resident badges To only delete a specific badge use the TiSferaDesign software 4 The device emits a long confirmation beep Manager master 5 The red LED flashes and then switches off to confirm that the deletion has been performed ...

Страница 18: ...eep and the green LED starts flashing The programming procedure starts 2 Using the key module 352000 352100 or the display 352500 select the apartment the resident badge must be associated to the reader will emit a beep to confirm 352500 M 01 managing residents using the apartment master 3 Configuration Manager master ...

Страница 19: ...be carried out in one stage 4 The flashing of the green LED and a short beep confirm that the apartment master badge has been saved 3 Move a new apartment master badge near the reader to save it Apartment Master A short beep and the switching off of the LED confirm that the programming sequence has been completed The Sfera Proximity Reader is ready for normal operation ...

Страница 20: ...tarts flashing Repeat the operation three times in succession 3 Configuration M 01 managing residents using the apartment master Three times Manager master The procedure will delete all the saved passpartout and apartment badges saved To only delete a specific badge use the TiSferaDesign software 3 The red LED flashes and then switches off to confirm that the deletion has been performed ...

Страница 21: ...it Resident 1 Place an apartment master badge close to the reader the reader emits a short beep and the green LED starts flashing The programming procedure starts Apartment Master 3 The flashing of the green LED and a short beep confirm that the resident badge has been saved M 01 managing residents using the apartment master ...

Страница 22: ...nd must be carried out in one stage 3 Configuration A short beep and the switching off of the LED confirm that the programming sequence has been completed The Sfera Proximity Reader is ready for normal operation 4 It is possible to continue to program further resident badges max 5 per apartment one after the other Resident ...

Страница 23: ...e emits a beep and the green LED starts flashing Repeat the operation three times in succession The procedure will delete all the stored resident badges To only delete a specific badge use the TiSferaDesign software M 01 managing residents using the apartment master Three times Apartment Master 3 The red LED flashes and then switches off to confirm that the deletion has been performed ...

Страница 24: ...he TiSferaDesign software or to update the firmware connect the Sfera Proximity Reader to the PC using a USB miniUSB cable miniUSB USB BUS When updating the software the device must be powered The Sfera Proximity Reader connected using an USB cable is recognised by the PC as a virtual port VIRTUAL COM ...

Страница 25: ...ossible to reset the Sfera Proximity Reader and delete all the previously set modules 1 Disconnect the power supply BUS press and hold down the programming pushbutton and reconnect the power supply 3 The red LED comes on for 4 seconds 2 Holding down the pushbutton until an extended beep is heard OFF OFF ON ON OFF OFF ON ON ...

Страница 26: ...max in operation Load of local relay contacts 8 A 30 Vdc 8 A 30 Vac cosφ 1 3 5 A 30 Vac cosφ 0 4 Operating temperature 25 70 C Technical After Sales Service BTicino only accepts responsibility for perfect device operation if it is installed to the state of the art respecting the indications of the product installation manual www bticino com ...

Страница 27: ...Sfera Proximity Reader Installer manual 27 ...

Страница 28: ...pA Via Messina 38 20154 Milano Italy www bticino com BTicino SpA reserves at any time the right to modify the contents of this booklet and to communicate in any form and modality the changes brought to the same ...

Отзывы: