2
MY HOME
Technical sheets - Automation
Main functions that can be set using the Tilocal Display software
Installation
Local Display is installed using a traditional procedure, using a box, support, and
AXOLUTE or LIVINGLIGHT cover plate; the device is not fitted with a temperature probe.
Therefore, it will not be necessary to comply with the probe installation requirements.
The recommended installation height is 150 - 160 cm.
Main possible functions using the software:
- selection of the operating mode to set for the device, temperature control, scenarios,
sound system, load management, consumption display.
- configuration of the settings of the probe and of its parameters;
- definition of the type of temperature central unit;
- parameters for the measurement of energy production, or consumption costs;
- configuration of the general device parameters;
- icon style definition.
Scenario programmer
In order to program, change or cancel a scenario, it is necessary to enable the
programming mode of the Module item F420 so that the status LED is green (press the
lock/unlock key on the Scenario Module for at least 0.5 seconds); continue with the
following operations:
1) press one of the four control keys the scenario should be associated to for 3
seconds. The screen shows the name and icon of the selected scenario and
the programming bar, to indicate that the learning procedure has started
If the device does not receive any input for 30 minutes from the start of the learning
procedure, programming will automatically be interrupted;
2) set the scenario using the corresponding controls for the various Automation,
Temperature control, Sound system, etc. functions;
3) confirm the scenario by quickly pressing the display
4) to change or create new scenarios to be linked to the other keys, repeat the procedure
starting from point 1.
To call a set scenario just press its pushbutton on the control quickly.
1 2
3 4
scenario 2
scenario 4
scenario 1
scenario 3
A
Room
0 – 9, room of the scenario module
item
PL
Light point
1 – 9, light point of the scenario
module item F420
MOD
Mode
1 – 4, scenario number (*)
FUN
Function
1
- Scenario control mode - FUN = 1
Thanks to this mode, it will be possible to manage and change 4 different associated
scenarios of the F420 scenario module, and activate them by pressing one of the 4 icons
shown on the display.
Local Display physical configuration
(*) Correspondence among the 4 icons and the numbers of the scenarios that can be
saved in the F420 module
Configurator MOD
Icon 1
Icon 2
1
Scenario 1
Scenario 2
2
Scenario 5
Scenario 6
3
Scenario 9
Scenario 10
4
Scenario 13
Scenario 14
Configurator MOD
Icon 3
Icon 4
1
Scenario 3
Scenario 4
2
Scenario 7
Scenario 8
3
Scenario 11
Scenario 12
4
Scenario 15
Scenario 16
NOTE:
Once the operations have been performed lock the programming, pressing the
lock/unlock pushbutton, of the senario module, for at least 0.5 seconds, so that the
corresponding LED becomes red.
To delete a scenario, proceed as follows:
1) the scenario module must be enabled for programming.
2) press the pushbutton of the scenario you want to cancel for at least 7 seconds;
The display will confirm that the scenario has been deleted and return to the main
screen.
To erase the entire memory keep the DEL pushbutton on the Scenario module
pressed for 10 seconds, the yellow “reset scenarios” LED flashes quickly.
HD4891 - HC4891 - HS4891
L4891 - N4891 - NT4891