![background image](http://html1.mh-extra.com/html/bticino/374005/374005_manual_2825431004.webp)
4
Front and rear view
Read carefully before use and keep for future reference
Touching the units with wet hands is forbidden
Using liquid cleaners or aerosols is forbidden
Blocking the ventilation openings is forbidden
Modifying the devices is forbidden
Removing protective parts from the devices is forbidden
Installing the units near liquids and powders is forbidden
Installing the units near heat sources is forbidden
Installing the units near harmful gases, metal dusts or similar is forbidden
Fastening the units on unsuitable surfaces is forbidden
Danger of electrical shock
Risk of devices falling because the surface on which they are installed collapses or inappropriate installation
Switch the power supply OFF before any work on the system
Caution: Installation, configuration, starting-up and maintenance must be performed exclusively by
qualified personnel.
Check that the wall installation has been carried out correctly
Lay out the wires respecting the standards in force
Connect the power supply wires as indicated
Use only the items indicated in the technical specifications for any system expansions
Warnings and consumer rights
Hereby, BTicino S.p.A., declares that the radio equipment type Small entrance panel 4.3" 374005 is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address: www.bticino.it/red
Remote operation may cause damage to people or property.
Configuration
The device must be configured by software. For software download, installation device documentation and for any
other information, refer to the website.
www.homesystems-legrandgroup.com
Technical data
Voltage
24 Vdc
Maximum consumption
0.65 A
C NC NO contact output
125 Vac/0.5A, 30Vdc/2A
Max. cable section for clamps
0.8 mm²
Operating temperature
(- 40) – (+ 70) °C
IP degree of protection
54
IK degree of protection
07
Camera resolution
1080 p
Camera viewing field angle
H= 80°; V= 53°
Face recognition distance during daytime
30-80 cm
Face recognition distance at night
30-50 cm
Badge reader frequency
13.56 MHz
Badge reader transmission power
< 42 dBuA/m @ 10m
1. LED for the shooting field lighting
2. Microphone
3. Light sensor
4. Camera
5. Display 4.3" (touch screen)
6. Badge reader for door lock opening
7. Loudspeaker
8. Locking screw
9. USB Connector (not used)
10. Reset to the factory settings push button
11. Not used
12. Connection clamp
13. Not used
14. RJ45 Connector (*)
15. Tamper switch
16. Mounting bracket
(*)
This device does not support standard POE power supplies,
but only POE power supplies identified with item no. 375002.
Connect the cat5/5e/6 FTP or cat5/5e/6 UTP cable with ferrite
supplied to the connector.
8
1
2
1
3
4
5
6
7
ISP
12
14
12
11
10
9
15
13
16
LOCK+
electric door lock connection and control
(12V - 4A impulsive on 3 Ohm maximum)
LOCK-
SENSE
door lock status signal input (dry contact)
GND – +12V
access control devices power supply
OPEN
third party access control signal input for door lock opening (+12Vdc pulse)
GND
system common ground terminal for third party connection
Door OPEN – GND
local door lock release pushbutton connection
FIRE Linkage – GND
local door lock release pushbutton connection for firealarm system
NO
interlocked contact
C
NC
DC24V
additional power supply clamps (not polarized)
Connection clamp
GND
Fire Linkage
Door Open
ISP
Содержание 374005