2
BT00641-a
344082
-EN
TECHNICAL SHEETS
N - handset number
Assigns to each handset an identification number within the system. The handsets
must be configured in progressive order. Handsets with parallel connection (max 3 are
allowed inside apartments without item 346850) must be configured using the same
N configurator.
P - entrance panel association
The P configurator identifies the associated EP, or the first entrance panel on which the
audio is activated when the (
) key is pressed, as well as which door lock is activated
when the key
is pressed while the handset is idle.
M - Operating mode of the keys
In addition to the door lock opening key
and the staircase light key (
), the
handset also has 4 programmable keys ( - - - ).
These keys may be associated to different operating modes (e.g. activation of external
actuators, intercom, activation of additional EPs, etc., based on the type of configurator
connected to M).
The handset offers the possibility to select among 16 types of bells with pre-programmed
ringtones, which can be associated to the following type of calls:
- Calls from the entrance panel (configured with S=0 - S=4)
- Calls from the entrance panel (configured with S=0 - S=5)
- Intercom call
- Floor call
(See the bell programming table in the following pages)
Configuration
Configurator in P
key ( ) function
0-9
Entrance panel audio activation
(configured with P=0-9)
Configurator in P
key
function
0-9
Opening of the EP door lock
(configured with P=0-9)