background image

3

321071

10” touch screen handsfree internal unit

 

BT00852-a-EN    

03/09/2014

Room Number

IU Type

Configuration

Click on the white circle to select “

With apartment interface 323009

” or “

Without 

apartment interface 323009

”. If you select “With apartment interface 323009”,you 

can’t set the room number because this is directly set by the apartment interface.  If 
you select “With apartment interface 323009, two modes are available: 

direct call 

mode 

and 

normal call mode

. With direct call mode, the room number is a digital 

value (1 to 4000). With normal call mode, the room number is a combination of floor 
number and room number. You need to set the room number and the maximum 
apartment quantity per floor.

Click on the white circle to select “

With lift controller

” or “

Without lift controller

”. 

If you select “With lift controller”, a lift icon  

  will appear in the main interface. In 

idle state, press this icon or the unlock key to call the lift. 

Note 

: lift control function should be equipped with a lift controller interface and 

supported by the lift manufacturers.  Default setting is without lift controller.

Click on the white circle to select SOS alarm contact status “

Normal open

” or 

Normal close

”.

Default setting is Normal open.

The alarm detector sub menus include two pages, the setting item in the first page as 
below :

Enable /Disable 

: enable or disable the detector, click on the  “Enable” or “Disable” to 

switch enable /disable.

Detector mode 

: set the detector normal open or normal close, select “ON” (normal 

open) or “OFF” (normal close) to switch detector mode.

Definition 

: define the detector type, (area1-infrared), (area2-door contact), (area3-

smoke), (area 4-gas), (area5-infrared/no infrared), (area 6- infrared/no infrared), 
(area 7- infrared/no infrared), (area 8- infrared/no infrared), click on the “infrared” or 
“no infrared” to switch detector definition of area 5 to area 8.  Area1 to area 4 can’t be 
changed.

Status 

: display the detector status, when it becomes blue detector is enabled and 

when it becomes gray means disabled.

Areas

 : show area1 to area 8 alarms.

Click on “

Reset

” to restore the parameters of the page to default value.

Click on the  

PgDn

  icon to have access to the second page. Setting item in the second 

page as below:

Alarm 

: define alarm whether with sound, click on the white circle to select “YES/ON”.

Effective time for alarmed 

: click on the white circle to set the effective time as 40 

sec./100 sec./150 sec./210 sec./225 sec.

Delay 

: when the detector monitors an alarm, it will report the message after the 

setting delay time.  You can click on the white circle to set the delay time as 40 sec./100 
sec./150 sec./210 sec./225 sec.   For Area 3 and Area 4 you can’t set delay time.

Click on “reset” to restore the parameters of the page to default value.
Click on the  

PgUp

  icon to return to the first page

Lift

Entry Panel

SOS

Restore

Detector

Click on the white circle to select “

Master

” or “

Slave

” IU.  When one apartment install 

multiple handsets, if the handsets be called, only the master handset opens the video, 
slave handsets do not open the video. If the slave handset answered, the other handset 
returns to static, the answered handset open the video and audio, and then you can 
talk with the entry panel. 
Default setting is master handset.

Click on the white circle to select “

Doorbell

” or “

Entry panel

”.  If the handset linked 

is a small entry panel, we can set whether monitor the small entry panel, if you select 

Monitor enable

”, “Video door phone” menu will display “  

  ”. 

When the small entry panel call handset, the handset will ring and turn on  the video; 
if linked with doorbell ,it can’t monitor and when the handset detect income signal the 
handset only ringing for 10 seconds.

Click on “

OK

” to restore all the parameters to default value or click on “

Cancel

” to abort 

your operation.