As the charging process begins, the red led will light and remain lit.  When the charge progress 
has progressed it will turn off and the yellow led lights indicating the charging process is 
proceeding.  When finally the yellow turns off and the green led is lit, the batteries are considered 
fully charged. 
If the red or yellow led is continually flashing, it indicates a fault of some type.  Refer to the 
troubleshooting information below to determine the possible cause. 
 

 

OPERATION 

 

Connect the battery pack, checking the polarity. 
Plug the charger into the AC supply, thus starting the automatic charging cycle.  
 
First a test is run on the battery voltage to decide if the charging process should be started or not. 
If the battery is not connected to the battery charger, or if the battery polarity is reversed the 
yellow led will flash continually. 
 
If the test is passed, a small click may be heard.  Following that the red led will come on solid. 
 
At the end of the charge, when the green indicator is on, disconnect the AC power supply and 
disconnect the battery pack.  (Some charging profiles have a float stage at the end of charge: in 
this case the charger needs to be left connected to the battery pack.) 

Troubleshooting 

 

PROBLEMS 

SOLUTIONS AND CHECKS 

The battery charger leds do not switch on 

Check that the plug is connected to the mains supply. 
Check the condition of the AC cordset and the AC input cable. 

The yellow led is flashing. 

Battery is not connected, or battery is connected in reverse or 
battery output is shorted. 

The red led is flashing. 

The safety timer has elapsed. Restart charge cycle and cycle 
begins OK, check batteries. 
If red led still flashes there may be an internal short circuit. Call 
for service. 

 

 RATING PLATE 

 The rating label on the unit provides the follow ing details: 
 

 Model 

 

 serial 

number 

 

date of manufacture 

 mains 

(input) 

voltage 

 

output voltage and current 

 

internal fuse rating 

 

max input current 

 

charging curve set at factory 

 

range of battery sizes possible

 

 
NOTE:  

The rating plate stipulates the initial setting of DC voltage and current.  The setting of 

your particular unit may be different.  Consult your dealer if unsure. 

 
OTHER TECHNICAL DATA 

 

Storage Temperature Range:   

- 40  to +50 degrees Celcius 

 

Relative Humidity Range: 

 

0 – 80% 

 

Operating Temperature Range:  

-10 to 45 degrees Celcius 

 

REPAIRS 

 

Repairs must only be carried out by qualified personel. 

 

Use only original equipment manufacturers (OEM) parts for repairs. 

 

Содержание Excel Series

Страница 1: ... equipment suits the voltage of the battery that the charging current suits the capacity of the battery and that the selected charging curve for lead acid wet batteries or VRLA i e gel or agm batteries is correct for the type of battery to be charged In addition make sure the rated input voltage of the charger suits the available supply voltage and the system is grounded Use battery chargers only ...

Страница 2: ...harging profiles have a float stage at the end of charge in this case the charger needs to be left connected to the battery pack Troubleshooting PROBLEMS SOLUTIONS AND CHECKS The battery charger leds do not switch on Check that the plug is connected to the mains supply Check the condition of the AC cordset and the AC input cable The yellow led is flashing Battery is not connected or battery is con...

Страница 3: ... EMC on these devices were carried out in compliance with the CEI EN55014 1 A2 04 98 06 99 and CEI EN 55014 2 10 98 STANDARD norms with the test instructions and conditions as requested by the norms NORM RESULT EN 55014 1 A2 COMPLIANT EN 55014 1 COMPLIANT EN 61000 3 2 COMPLIANT EN 61000 3 3 COMPLIANT EN 61000 4 2 COMPLIANT EN 61000 4 4 COMPLIANT EN 61000 4 5 COMPLIANT EN 61000 4 6 COMPLIANT EN 610...

Страница 4: ...tensité admissibles de recharge de la batterie sont conformes à la tension et à l intensité de recharge du chargeur De même assurez vous que la courbe de recharge sélectionnée batteries plomb acide à électrolyte liquide ou VRLA autre terme pour les batteries scellées qu elles soient de type AGM ou gel est appropriée au type de batterie à recharger De plus assurez vous que la tension d alimentation...

Страница 5: ...s allume en continu À la fin du cycle de recharge lorsque la DEL verte est allumée en continu débranchez le chargeur de sa source d alimentation CA et débranchez la batterie du chargeur Certains profils de recharge incluent une étape d entretien de la charge dans ce cas ne débranchez pas le chargeur de son alimentation et ne débranchez par la batterie du chargeur Dépannage PROBLÈMES VÉRIFICATIONS ...

Страница 6: ...re 10 3 Efficacité 85 4 Ondulations parasites CA charge nécessitant moins de 150 mV 5 Précision de la mesure de la puissance et de la tension 2 COMPATIBILITÉ ÉLECTROMAGNÉTIQUE Les essais de compatibilité électromagnétique EMC de ces appareils ont été effectués conformément aux normes CEI EN55014 1 A2 04 98 06 99 et CEI EN 55014 2 10 98 NORME RÉSULTAT EN 55014 1 A2 CONFORME EN 55014 1 CONFORME EN 6...

Отзывы: