mBSC0800S-005-RUCM11
MBSC2100-005-RUCM11
April 15, 2013
Page 67
5.5.2 System Alarms
The mBSC0800S-005-RUCM11 provides alarm indications for equipment malfunctions or for conditions that
place the out of standard operating range (such as over-power). A complete list of alarm events, and the
originating product module, is provided in Table 16System Alarms.
These events are enabled by default factory settings, but can be disabled if desired.
These alarm events can be observed in multiples ways:
- In the EMS Local GUI in the network topology view and corresponding component parameter
windows
- In the Monitor window of the remote EMS Server
- As SNMP traps issued by the remote EMS Server (if enabled)
Table 16System Alarms
Item
Equipment
Module
Alarm
ID
Alarm
Name
Description
1
401500
Host/Remote
Link
Optical
RX
signal
is
detected
by
the
FIU
but
no
logical
connection
exists
to
the
Remote
Node
(CM)
2
Host
Unit
RCU
423000
System
Temperature
A
system
over
‐
temperature
alarm
has
been
reported
3
401500
Host/Remote
Link
Optical
RX
signal
is
detected
by
the
FIU
but
no
logical
connection
exists
to
the
Remote
Node
(CM)
4
422000
Optical
Transceiver
1
Low/No
optical
signal
is
detected
on
Link
1
5
Host
Unit
FIU
422100
Optical
Transceiver
2
Low/No
optical
signal
is
detected
on
Link
2
6
401500
Host/Remote
Link
Optical
RX
signal
is
detected
by
the
CM
but
no
logical
connection
exists
to
the
Host
Unit
(FIU)
7
423000
System
Temperature
A
system
over
‐
temperature
alarm
has
been
reported
408301
Fan
1
Alarm
Fan
1
is
non
‐
functioning
(low
current)
408302
Fan
2
Alarm
Fan
2
is
non
‐
functioning
(low
current)
8
Remote
Node
RTM
400100
Power
Down
Power
has
been
lost
at
the
Remote
Node
(internal
battery
backup
enables
alarm
delivery)
9
401920
PA
Over
VSWR
High
VSWR
detected
at
output
of
PA
10
427000
PA
Over
Output
Power
PA
output
power
exceed
threshold