INSTALLATION MANUAL DD700
1.2 Version with cable glands
Figure 1.2-1 - Calibration button - Stainless steel terminal version
Key:
1. Terminal opening protection seal
2. Stamped self-adhesive label sealing the protective screw of the calibration switch
3. Calibration switch
Referring to the previous figure, proceed as follows:
Switch the terminal on.
Remove the seal (ref. 1), unscrew the four screws on the cover of the terminal and open it,
being careful not to detach the display connector.
Remove the self-adhesive label (ref. 2) which seals the access hole to the calibration switch.
Using a non-metal tool, press the calibration switch (ref. 3).
ATTENTION
Removing the metrological stamps makes it impossible to use the weighing terminal for
commercial transactions towards third parties. To restore them, contact the After-Sales Service of
the Assistance Network.