BT Visitor Phone Скачать руководство пользователя страница 5

BT Visitor Phone Quick Install Guide 

 

Issued by: North Supply Ltd 

Issue no: BTDE020201/01 
Date: May 2018 

Page 5 of 7 

 

 

In strictest confidence 

Number to be dialed when 
“Call” button pressed 

*100 + X ( tone) + DN + # 
Note: x = 1 (Day) or 2 (Night)  DN = Up to 20 
digits 

1 = Day 

Exit Programming Mode 

*911 

 

 
 

1.4

 

Telephony Operations 

Function 

Programming Code 

Default Value 

The day/night operator 
destination number (DN) will 
be dialed when “Ring” 
button is pressed respective 
to day/night operational 
mode. 

*    1    0    0  + X (tone) + DN +    # 
Where: 
X = 1 day 
X = 2 night 
Destination number (DN) = up to 20 digits, 
including *, #, pause and A-D characters 

Day - Empty 
Night - Empty 

Delete a day or night 
operator 
destination number (DN). 

*    1    0    0  + X (tone) +    # 
Where: X = 1 day 
X = 2 night 

 

Programming 1 digit(s) 
prefix to allow dialing 
outgoing calls. 
When beginning with these 
digits, the door phone will 
process dialing. 

*    1    0    1  + Prefix  +    # 
Prefix: digits 0~9 only 
To cancel this operation enter: 
*    1    0    1    +    # 
Example: Command “101 259 # (tone)“ allows 
dialling to destination numbers with first digit 2, 
5 and 9. 
Note: Parameter don’t take effect on Speed Dial 
memories destination numbers dialling. 

 

The maximum conversation 
time (sec) 

*    1    0    2    +    XX 
Where: XX = seconds (10-99) 
00 = Unlimited 

60 seconds 

Time interval between DTMF 
digits during outgoing 
dialing 

*    1    0    3    +    X 
Where: X = 1-9 (each step is 200 msec) 

=2 (400 msec) 

Inter digits dialing time out 
(in sec) 

*    1    0    4    +    X 
Where: X = seconds 1-9 

3 sec 

Number of busy tone cycles 
in order to detect the busy 
signal 

*    1    0    5    +    X 
Where: X =0-9 (0 - no busy detection, 1-2 
cycles, 2-4 cycles etc.) 

3 (6 cycles) 

Busy signal cadence 
configuration for busy 
detection 

*    1    0    6    +    X    (tone) + Y (tone) + NNNN 
Where: X = 1 - busy cadence 1 
X = 2 - busy cadence 2 
Y = 1 - On, Y=2 - Off 
NNNN - time in msec 

1-500 On, 500 Off 
2 - 250 On, 250 
Off 

Pause time after  pick up a 
line and before dialing 

*    1    0    7    +    X 
Where: X = time in sec 1-9 

The minimum time in 
seconds to detect 
continuous tone 

*    1    0    9    +    X 
Where: X = time in sec 1-9 

Содержание Visitor Phone

Страница 1: ...In strictest confidence Visitor Phone BT Visitor Phone Quick Install Guide Issue No BTDE02020101 Issue Date May 2018 ...

Страница 2: ...Issue no BTDE020201 01 Date May 2018 Page 2 of 7 In strictest confidence Contents Page 1 Applicable model 4 1 1 Connection diagram 4 1 2 Help and assistance 4 1 3 Programming guide 4 1 4 Telephony Operations 5 1 5 Telephony Line Configuration 6 1 6 Administration 6 ...

Страница 3: ... Guide Issued by North Supply Ltd Issue no BTDE020201 01 Date May 2018 Page 3 of 7 In strictest confidence Executive summary This document provides guidance to the field engineering communities for on how to install BT Visitor Phone ...

Страница 4: ...gramming mode using the adjacent overleaf programming guide The unit is powered using the supplied power supply For help and assistance please call 0116 257 8147 option 2 1 3 Programming guide Function Programming Code Default Value Enter Programming Mode 911 tone Enter Admin Password 12345 12345 BT Visitor Phone Black BT Visitor Phone Silver Screw rubber gasket and metal back plate to the wall us...

Страница 5: ...0 1 Prefix Prefix digits 0 9 only To cancel this operation enter 1 0 1 Example Command 101 259 tone allows dialling to destination numbers with first digit 2 5 and 9 Note Parameter don t take effect on Speed Dial memories destination numbers dialling The maximum conversation time sec 1 0 2 XX Where XX seconds 10 99 00 Unlimited 60 seconds Time interval between DTMF digits during outgoing dialing 1...

Страница 6: ... X Where X 1 8 6 Microphone volume adjustment 3 0 3 X Where X 1 9 6 Continuous tone detection time 3 0 5 X Where X time in sec 1 6 Administration Function Programming Code Default Value Enter to programming mode 9 1 1 Switch door phone to the Day Night operational mode 9 0 1 Day mode 9 0 2 Night mode Note Allowed for system operator as well Day Programming login time 9 0 3 XXX Where XXX time in se...

Страница 7: ...Offices worldwide British Telecommunications plc 2017 Registered office 81 Newgate Street London EC1A 7AJ Registered in England No 1800000 ...

Отзывы: