BT SIP Access Control System Quick Install Guide 

 

Issued by: North Supply Ltd 
Issue no: BTDE0202BB02 

Date: July 2019 

Page 4 of 6 

 

 

In strictest confidence 

2.

 

The default IP Door Phone IP address is 10.10.10.6 and it is configured as 
‘Static’ IP address. 

3.

 

The default web-programming Administrator credentials are: 

3.1.

 

User name: ‘admin’ – For Administrator management level and ‘user’ – 
for User management level. 

3.2.

 

Default Password: 1234 for both management levels. 
 

PCB elements 

Description 

1 ( SW2) 

Factory Default Settings switch: 
‘Normal’ – Door Phone normal working position ‘Default’ – Set to 
default procedure mode 

Hardware Reset ( Cold Reset Switch) 

3 ( NO/NC Jumper) 

Relay 1 and Relay 2 Normally Open and Normally Close status jumper. 
Closed Central Pin (2) + ’NO’- (1) pin means the ‘Normally open’ mode. 
Closed Central Pin (2) + ’NC’ - (3) pin means the ‘Normally Close’ mode 
Note: Relay 2 works in Normally Open (NO) mode only 

Microphone Connector 

Speaker Connector 

6-Ethernet 

POE+/LAN connection 

5VD (5V DC) 

External power supply 5VDC 2A input (if no POE+ applied). 
Draw attention on connection polarity: +5V and GND marked on PCB 
(Fiure 6-2) 
The External Power Supply is not included in standard IP394X package 

SEN 1/2 (Sensor 1/2*) 

Door status detector. 
Also can be used as external Switch button connection (Chapter 8.3). 
Note: 
The External Switch button can be used for manual door opening 
usually labelled N/O and C or CMN and Make on the terminals 

REL 1/2 (Relay 1/2) 

Support 30VDC 2A 
Internal relays Normally Open and Normally Close status depends on 
JP1 jumper position. 

Audio Out* 

Reserved for future release 

 

1.3

 

Help and assistance 

Prior to calling, please check the following: 

1.

 

You know the extension number the door unit is connect to on the PBX. 

2.

 

You can dial the door unit and generate DTMF tones from the PBX. 

3.

 

The unit is powered by POE+ or the supplied power supply. 

4.

 

Check you are using the correct door release type relative to the power 
supply i.e. DC release as standard. 

5.

 

To view the full install guide please refer to the CD included with the unit. 

Содержание SIP

Страница 1: ...In strictest confidence SIP Access Control BT SIP Access Control System Quick Install Guide Issue No BTDE0202BB02 Issue Date July 2019 ...

Страница 2: ...th Supply Ltd Issue no BTDE0202BB02 Date July 2019 Page 2 of 6 In strictest confidence Contents Page 1 Applicable model 3 1 1 Connection diagram overview 3 1 2 Programming guide 3 1 2 1 Access to Web Management interface 3 1 3 Help and assistance 4 1 4 Attention 5 ...

Страница 3: ...BT Access Control System 1 Applicable model 1 1 Connection diagram overview 1 2 Programming guide 1 2 1 Access to Web Management interface 1 The programming application can be launched from a web browser To run the application type in address bar the IP Door phone IP address BT IP Access Control Unit with inbuilt camera BT IP Access Control Unit with inbuilt camera and display Screw rubber gasket ...

Страница 4: ...5 Speaker Connector 6 Ethernet POE LAN connection 5VD 5V DC External power supply 5VDC 2A input if no POE applied Draw attention on connection polarity 5V and GND marked on PCB Fiure 6 2 The External Power Supply is not included in standard IP394X package SEN 1 2 Sensor 1 2 Door status detector Also can be used as external Switch button connection Chapter 8 3 Note The External Switch button can be...

Страница 5: ...ovided two wire terminal connectors 2 Insert wired terminal connectors into the mating sockets on PCB Figure 6 2 3 Connect POE LAN cable to RJ 45 socket 4 Connect door lock to REL 1 Relay 1 and or REL 2 Relay 2 via the lock supply 5 If an external press to exit button is used See also chapter 7 6 in user manual Web GUI Door Functions Sensor connect the external switch button wires to SEN 1 Sensor ...

Отзывы: