Page 6 of 40
Installation, Maintenance and Operation Manual V24a (June 2012)
British Telecommunications plc 2012
SELV Connectors
Connectors J1300, J1301 (pin inputs) J1400 (outputs), J1000 (alarm panel), J600 (Ethernet) and J
800 (DC power) have been classified as SELV and must only be connected to approved SELV
circuits. If the circuit to be connected to these terminals is not SELV an isolation unit compliant with
local market regulatory requirements must be used. SELV circuits are determined in IEC60950 and
equivalent national standards.
Operating Conditions
The Redcare Secure unit is rated to operate under the following conditions:
-
Indoor operation
-
Ambient temperature: -5
o
C (23
o
F) to +55
o
C (131
o
F)
-
Humidity: 5% to 95%
Note: It is recommended to use a power supply capable of providing at least 450mA at
13.8VDC for this product.