4.2.6.6- Priming the pump.
Once the acid pump has been installed, it should be primed to eliminate the
installation air.
Go to the "pH" menu and select "Manual". Keeping the "OK" button pressed,
the pump will be running. Keep the pump running with the "OK" button until
the liquid has passed throughout the tube until injection.
4.2.6.7- Acid - Alkaline
Access the configuration menu of the equipment to pass the pH control from
acid to alkaline. To do this, press "OK" in the main screen, in configuration "S"
press button
until reaching the ACID line. ALKALI? Press "OK" and the letter
"N" will appear with the arrow
. Select “S” to remain in the ALKALI screen.
ACID?
4.2.6.8- Automatic shutdown and error message.
If the acid pump shuts down and the message "pH ERROR" appears, the pump
has been operating too long without the pH value lowering to the required
level. The causes could be:
-There is no acid.
-Problem in the pump or in the acid duct.
-The probe or probe cable are damaged.
NOTE: to eliminate the error, press the "OK" button
4.2.7- Relay
The EVO series equipment have a programmable auxiliary relay that can be
used to control the filtering pump, swimming pool lighting and others features
See pages 23 and 24 of this manual for further details.
4.2.7.1-
Start/Stop
This manually turns the relay on / off.