9.1.

 Numeric 

Test 

This test examines whether the cable qualifies to the standards such as those for 10 base-T, 100 base-TX, and 1000 base-T in terms of 

the crosstalk. 

 

 

Figure 20 Numeric Test for Crosstalk 

 

Type of applications. 

 

  changes the highlight. 

 

To select application, press 

 or 

  when highlighted. The selected applications are marked by ‘

’. 

 

To start test with the selected applications, press 

26 

Содержание BT603

Страница 1: ...User s Manual BT603 Copyright 2010 Caltek Industrial HK Ltd All rights reserved...

Страница 2: ...on with WHAT IS COVERED COVERAGE LENGTH OF COVERAGE BT603 MAIN UNIT One 1 year from the date of purchase by original buyer or end user PARTS AND ACCESSORIES Ninety 90 days from the date of purchase by...

Страница 3: ...r Information 9 6 2 Setting System Setup 10 7 Communication with External Devices 12 7 1 Uploading Stored Data to a PC 12 7 2 Printing Test Results 12 8 TDR Testing 14 8 1 Operation Principles 14 8 2...

Страница 4: ...1 2 1 Using DHCP Server 33 11 2 2 Assigning Static IP Address 34 11 3 Link Blink 35 11 4 PING Test 36 11 5 Collecting Network Information 36 dditional Functions 39 12 1 Characteristic Impedance Test 4...

Страница 5: ......

Страница 6: ...damage to the tester and or a hazardous to the user Hence the user must assume the responsibility for ensuring his her safety CAUTION 1 Ban on measuring a live or charged wire 2 Measure after dischar...

Страница 7: ...2001 EMC EN 61326 1997 A1 1998 EMC Standard Category Pass ESD IEC 1000 4 2 A EM IEC 1000 4 3 A Burst IEC 1000 4 4 A Surge IEC 1000 4 4 A Conducted RF IEC 1000 4 4 A Class Machinery This test is certi...

Страница 8: ...floors etc It also provides a Continuity test function to check out the continuity of cable BT603 is a high tech all in one instrument suitable for installing repairing and maintaining business networ...

Страница 9: ...BT603 Users Manual 3 Physical Features 4 Figure 1 Exterior of BT603...

Страница 10: ...er on off button Backlight on off button Additionally pressing this button for more than three seconds will turn on off the button sound Setup button for selecting test parameters Mode button for sele...

Страница 11: ...connector Shielded Twisted Pair STP Cable Connect it directly to the RJ45 connector Unshielded Twisted Pair UTP Cable Connect it directly to the RJ45 connector Unshielded Multi Core Cable After conne...

Страница 12: ...o select a function use to highlight the item press or TDR test See page 14 Wiremap test See page 29 Network analysis See page 31 Crosstalk test See page 25 Additional test functions See page 39 Auto...

Страница 13: ...rmation system setup and uploading stored data to a PC To select a category use to highlight the field press or For more information about setting user information see Section 6 1 For more information...

Страница 14: ...tting User Information To edit settings press to highlight the field then press You can use User Name as the operator s name and Affiliation as an abbreviated company name Use the buttons to select th...

Страница 15: ...previous value To exit this menu press after or before changing values at this point the cursor is not blinking Pressing or selects or confirms or starts the selected function To alter the screen con...

Страница 16: ...the cursor and changes the highlighted character Available characters are 0 1 2 3 4 5 6 7 8 9 a b c d e f To exit this menu and save changes press To exit this menu without saving changes press To al...

Страница 17: ...e 7 Uploading Screen After connecting the tester to the PC press or to start the download Ensure the software is running on the PC 7 2 Printing Test Results The test results including the measured wav...

Страница 18: ...d tester is ready for printing The tester cannot detect an attached printer Printer is not connected An error has occurred during printing Check the printer or refill printer paper then try again The...

Страница 19: ...an open cable both the initial pulse and its reflected signal have the same polarity while the inverse polarity occurs in a shorted cable The interval between Position and corresponds to the time diff...

Страница 20: ...a TDR Function Use the arrow keys to highlight the required test The words Graphic and Numeric mean that the tester shows the results in the form of waveform or numeric displays respectively For LAN...

Страница 21: ...ely See Section 8 6 The cursors must be located at the beginning of reflections The numbers shown indicate the pair being used on the RJ45 connector BNC indicates the BNC connector is being monitored...

Страница 22: ...speed of light in vacuum Pulse is the horizontal time width of the pulse for the TDR testing as the width increases the maximum measurable distance increase since the total energy of the pulse is incr...

Страница 23: ...can use FILE NAME as the filename and LOCATION as the location where the current test is performed Fields for location and name entry moves the cursor and changes the highlighted character To exit th...

Страница 24: ...the memory sector press Information fields To exit this menu without loading any data press or To load the result press then the tester asks you to load or not Select the highlighted answer using pres...

Страница 25: ...To change the memory sector press Information fields To exit this menu without deleting any data press or To delete the result press then the tester asks you to delete or not Select the highlighted an...

Страница 26: ...or and changes the highlighted character To start testing press or To go back to the previous menu press or before test After test press to go back to the previous menu Calculated distances to the det...

Страница 27: ...P value used to calculation of distance It is the percentage of the speed of light moves the cursor and changes the highlighted character To start testing press or To go back to the previous menu pres...

Страница 28: ...n the width of the measuring pulse can be increased or decreased using the 8 7 Measurement Accuracy and VOP If the VOP is set accurately the tester performs at an accuracy of 4 for coaxial UTP and STP...

Страница 29: ...ted by pairs in order to make it less vulnerable to crosstalk It makes VOP to deviate approximately by 2 You can determine a cable s actual VOP by adjusting the measured length to match a known length...

Страница 30: ...TP or STP using the RJ45 connector Figure 19 Selecting Crosstalk Test The tester provides two types of crosstalk test See 9 1 and 9 2 changes the highlighted item Press or then the selected item is ma...

Страница 31: ...ch as those for 10 base T 100 base TX and 1000 base T in terms of the crosstalk Figure 20 Numeric Test for Crosstalk Type of applications changes the highlight To select application press or when high...

Страница 32: ...ays an error message Confirm that cable connection is correct or use a longer cable If the cable tested meets the standards it shows Pass If not it shows Fail To perform the test again press To select...

Страница 33: ...shows the current setting To change its mode press See Section 8 6 Distance between Cursor1 and Cursor2 or VOP To swap them press Cursor1 and Cursor2 To move them use with its mode set to CURSOR1 and...

Страница 34: ...shows faults such as open shorted reversed crossed and split pairs which can arise in cabling This test requires the remote identifier which should be attached to the far end of the cable Note that t...

Страница 35: ...or the pair press then you can see the result of each pair To perform the test again press Test result message Pairs in the cable ID number of the remote identifier connected to the tester The test re...

Страница 36: ...ces connected to the network 11 1 Inspecting Activity of the Port Figure 24 is displayed if the port is active Figure 24 When the Port is Active Advertised speed and duplex that are supported by a net...

Страница 37: ...ection 11 3 Press or to go back to the previous menu Press or to start the selected function Figure 25 is displayed if the RJ45 connector is not correctly connected to the port or there is no network...

Страница 38: ...mask and DNS server address The result is displayed as in Figure 26 Figure 26 Searching for a DHCP Server The tester finds a DHCP server Press to go back to the previous menu Assigned IP address of th...

Страница 39: ...Address When no DHCP server is available you can assign the network setting manually Figure 27 Assigning Fixed IP Address IP IP address NM subnet mask GW gateway address The IP Net Mask and Gateway f...

Страница 40: ...er setting the information then press to move to the next screen 11 3 Link Blink This function helps you determine which cable is connected to which port on a network hub or switch This function gener...

Страница 41: ...tester may not receive any response Figure 29 PING Test The round trip time in mili seconds Press or to go back to the previous menu Press to perform the ping test again 11 5 Collecting Network Inform...

Страница 42: ...ile to stop collecting IP addresses of the devices In this figure the highlighted device has the address of 192 168 0 1 Device names on the network MAC addresses of the devices In this screen only fir...

Страница 43: ...to see more detailed information of the highlighted device Number of the device and the total number of detected devices changes the selected devices Press or to go back to the previous step Press to...

Страница 44: ...provides three additional functions Characteristic impedance test Continuity test and Tone generation Figure 31 Menu Screen of Additional Functions To select the item use or to highlight the item then...

Страница 45: ...2 RJ45 3 6 RJ45 4 5 RJ45 7 8 RJ45 BNC Characteristic impedance It is calculated on the position of Cursor2 therefore it should be located within the cable length Distance between Cursor1 and Cursor2 o...

Страница 46: ...red resistance If this does not exceed 150 then a buzzer sound is generated so that the continuity of the cable is confirmed Connector used for testing To change the connector press or then the test i...

Страница 47: ...frequency of 810 1100 Hz through the connector therefore it is possible to trace the cable with a standard tone probe not supplied available from most electrical outlets Figure 34 Tone Generation To s...

Страница 48: ...r the TDR test provides the information of cable length and delay skew by pairs 13 1 Selecting Test Functions Figure 35 Selecting Auto Test Functions Test items To select them move the highlight using...

Страница 49: ...window by window manner Figure 36 Auto Test Result LAN TDR Cable pairs Distance to termination Type of termination OP stands for open end SH does for shorted end To move to the next page test result p...

Страница 50: ...ult 10 BASE T 100 BASE TX and 1000 BASE T Cable pairs When the pair passes the test PASS is displayed If not FAIL is displayed To move to the next page test result press To perform the test again pres...

Страница 51: ...ed by the tester to measure signal 4x4 table shows the results To move to the next page test result press To perform test again press Figure 39 Auto Test Result Continuity Cable pairs Resistance betwe...

Страница 52: ...test results by pressing the button during the auto test The tester provides 50 sectors to save the auto test results You can easily manage the sectors as shown in Figure 13 Figure 14 and Figure 15 F...

Страница 53: ...you purchased the tester from Warning To avoid possible fire electric shock personal injury or damage to the tester Do not open the case No user serviceable parts are inside Replacing electrical part...

Страница 54: ...supported and adopted this instrument warranty period up to 90days from the original purchase date 1 Complimentary Support Technical Material issue within first 90days warranty period 2 Support Incide...

Страница 55: ...xing IP test Link partner ability measurement 10M half 10M full 100M half 100 full 10M half 10M full 100M half 100 full duplex support function MAC address editing IP scan IP MAC address NetBIOS name...

Страница 56: ...e signal transmission Display 2 5 128 x 64 mono graphic LCD Power 11 8 V Li Polymer 1 800 mAh 15 V 1 A AC DC adapter Operating time 6 hours charging time 4 hours Peripherals USB cable provided Serial...

Отзывы: