background image

BT-62

IR THERMOMETER

OPERATION MANUAL

          1.     SAFETY RULES

To ensure that the meter is used safely, follow all safety and operating instructions in 

this operation manual. If the meter is not used as described in this operation manual, 

the safety features of this meter might be impaired.

Do not look directly into the laser beam when the device is in use–permanent eye 

damage may result.

Use extreme caution when operating the laser.

Never point the device towards anyone’s eyes.

Keep out of reach of children.

          2.     INTERNATIONAL SYMBOLS

          3.     SPECIFICATIONS

Important information

see manual

Laser device. Avoid towards 

anyone’s eyes

Measurement Range

-50 to +460°C (-58 to +860°F)
0 to 50°C (32 to 122°F)

0.95 fixed

0.2°C/0.5°F

1sec

Operating Range

Accuracy (Tamb. = 

23±3°C)

±1.5°C (2.7°F)

Emissivity
Resolution
Response Time 

(90%)

12:1

Distance: Spot

Weight

~180 g (6.3 oz) including batteries (AAA*2pcs)

114 x 162 x 40 mm (4.5 x 6.4 x 1.6 inch)

Battery Life

Typ. 18, min 14 hours continuous use (Alkaline battery)

Dimensions

** The thermometer will automatically shut off if left idle for more than 15sec.

          4.     THERMOMETER DESCRIPTIONS

5.     OPERATION

WARNING

The measurement range is for thermometers only. Users should choose proper probe 

types for different kinds of applications. Please make sure the target to be measured 

will not exceed the temperature range of the probe to avoid permanent damage to the 

thermocouple probe.
Caution: To avoid electric shock and thermometer damage, do not measure the live 

circuit with the thermocouple probe voltage exceeding 24V AC RMS or 60V DC.

EMC/RFI: Readings may be affected if the unit is operated within radiofrequency 

electromagnetic field strength of approximately 3 volts per meter, but the instrument's 

performance will not be permanently affected.

5.1     Function Selection

Display

Function

Simply aim the thermometer at the measure target with Lens (4) 

and press Meas. key (6) to display the surface temperature.
During the measurement, the MAX reading will be displayed 

beside the              icon.

5.2     Other Function Selection

°C of °F

Press Mode Key (2) for °C or °F transferred.

LCD Backlight: Always on.

Recall the last reading memory by pressing Mode Key (2) 

while power off

1)

2)

3)


5.4     LCD Error Messages

The Thermometer incorporates visual diagnostic messages as follows:

‘Er2’ is displayed when the thermometer is exposed to rapid 

changes in the ambient temperature. ‘Er3’ is displayed 

when the ambient temperature exceeds 0°C(32°F) or +50°C 

(122°F).

The thermometer should be allowed plenty of time (minimum 

30 minutes) to stabilize to the working/room temperature.

Error 5~9

, for all other error messages it is necessary to reset 

the thermometer. To reset it, turn the instrument off, remove the 

battery and wait for a minimum of one minute, reinsert the battery 

and turn on. If the error message remains please contact the 

Service Department for further assistance.

‘Hi’ or ’Lo’ is displayed when the temperature being 

measured is outside of the measurement range.

Accuracy (Tobj=

15-35°C,Tamb=25°C)

Tobj=0~460°C: ±2.5% of reading or 2.5°C (4.5°F) whichever is 

greater

Tobj=-50~0 °C: ±(2.5°C+0.05/°C)

The thermometer is a non-contact infrared thermometer, and always with Real-Time Maximum 

(MAX) data.Please remember to keep away from children and don’t use it for safety related 

applications.

Backlight
Laser

Classllla Laser: Always enable while measuring.

Memory

The Distance:Spot is 12:1. Please make sure the target area is 

within the field of view.

Отзывы: