WARNING FOR YOUR PROTECTION

READ THE FOLLOWING:

KEEP THESE INSTRUCTIONS
HEED ALL WARNINGS
FOLLOW ALL INSTRUCTIONS
THE APPARATUS SHALL NOT bE ExPOSED TO DRIPPING OR SPLASHING 

LIqUID AND NO ObjECT FILLED WITH LIqUID, SUCH AS vASES, SHALL 

bE PLACED ON THE APPARATUS
CLEAN ONLY WITH A DRY CLOTH.
DO NOT bLOCK ANY OF THE vENTILATION OPENINGS. INSTALL IN 

ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS.
DO NOT INSTALL NEAR ANY HEAT SOURCES SUCH AS RADIATORS, HEAT 

REGISTERS, STOvES, OR OTHER APPARATUS (INCLUDING AMPLIFIERS) 

THAT PRODUCE HEAT.
ONLY USE ATTACHMENTS/ACCESSORIES SPECIFIED bY THE MANU-

FACTURER.
UNPLUG THIS APPARATUS DURING LIGHTNING STORMS OR WHEN 

UNUSED FOR LONG PERIODS OF TIME.

Do not defeat the safety purpose of the polarized or grounding-type plug.  

A polarized plug has two blades with one wider than the other. A grounding 

type plug has two blades and a third grounding prong. The wide blade or 

third prong are provided for your safety. If the provided plug does not fit your 

outlet, consult an electrician for replacement of the obsolete outlet.
Protect the power cord from being walked on or pinched particularly at 

plugs, convenience receptacles, and the point where they exit from the 

apparatus.
Use only with the cart stand, tripod bracket, or table specified by the 

manufacture, or sold with the apparatus. When a cart is used, use caution 

when moving the cart/apparatus combination to avoid injury from tip-over.  

Refer all servicing to to qualified service personnel. Servicing is required 

when the apparatus has been damaged in any way, such as power-supply 

cord or plug is damaged, liquid has been spilled or objects have fallen into 

the apparatus, the apparatus has been exposed to rain or moisture, does 

not operate normally, or has been dropped.

POWER ON/OFF SWITCH: 

For products provided with a power switch, the 

power switch DOES NOT break the connection from the mains.

MAINS DISCONNECT: 

The plug shall remain readily operable. For rack-

mount or installation where plug is not accessible, an all-pole mains switch 

with a contact separation of at least 3 mm in each pole shall be incorporated 

into the electrical installation of the rack or building.

FOR UNITS EqUIPPED WITH ExTERNALLY ACCESSIbLE FUSE RECEPTACLE: 

Replace fuse with same type and rating only.

MULTIPLE-INPUT vOLTAGE: 

This equipment may require the use of a differ-

ent line cord, attachment plug, or both, depending on the available power 

source at installation. Connect this equipment only to the power source 

indicated on the equipment rear panel. To reduce the risk of fire or electric 

shock, refer servicing to qualified service personnel or equivalent.
If connected to 240V supply, a suitable CSA/UL certified power cord shall 

be used for this supply.

SAFETY INSTRUCTIONS 

NOTICE FOR CUSTOmERS IF YOUR UNIT IS EqUIPPED WITh A POWER CORD.
WARNING: ThIS APPLIANCE ShALL BE CONNECTED TO A mAINS SOCKET OUTLET 

WITh A PROTECTIVE EARThING CONNECTION.
The cores in the mains lead are coloured in accordance with the following code:

GREEN and YELLOW - Earth        bLUE - Neutral        bROWN - Live

As colours of the cores in the mains lead of this appliance may not correspond 

with the coloured markings identifying the terminals in your plug, proceed 

as follows:

•  The core which is coloured green and yellow must be connected to 

the terminal in the plug marked with the letter E, or with the earth 

symbol, or coloured green, or green and yellow.

•  The core which is coloured blue must be connected to the terminal 

marked N or coloured black.

•  The core which is coloured brown must be connected to the terminal 

marked L or coloured red.

 

This equipment may require the use of a different line cord, attachment 

plug, or both, depending on the available power source at installation.  

If the attachment plug needs to be changed, refer servicing to qualified 

service personnel who should refer to the table below. The green/yel-

low wire shall be connected directly to the units chassis.

CONDUCTOR

WIRE COLOR

Normal

Alt

L

LIVE

BROWN

BLACK

N

NEUTRAL

BLUE

WHITE

E

EARTH GND

GREEN/YEL

GREEN

WARNING: 

If the ground is defeated, certain fault conditions in the unit 

or in the system to which it is connected can result in full line voltage 

between chassis and earth ground. Severe injury or death can then 

result if the chassis and earth ground are touched simultaneously.

The symbols shown above are internationally accepted symbols 
that warn of potential hazards with electrical products. The 
lightning flash with arrowpoint in an equilateral triangle means 
that there are dangerous voltages present within the unit. The 
exclamation point in an equilateral triangle indicates that it is 
necessary for the user to refer to the owner’s manual.

These symbols warn that there are no user serviceable parts inside 
the unit. Do not open the unit. Do not attempt to service the 
unit yourself. Refer all servicing to qualified personnel. Opening 
the chassis for any reason will void the manufacturer’s warranty. 
Do not get the unit wet. If liquid is spilled on the unit, shut it off 
immediately and take it to a dealer for service.  Disconnect the 
unit during storms to prevent damage.

IMPORTANT SAFETY INSTRUCTIONS

Содержание Soundweb London BLU-102

Страница 1: ...1 Soundweb TM London BLU 102 Installation Guide 18 0771 B ...

Страница 2: ...source indicated on the equipment rear panel To reduce the risk of fire or electric shock refer servicing to qualified service personnel or equivalent If connected to 240V supply a suitable CSA UL certified power cord shall be used for this supply Safety Instructions Notice For Customers If Your Unit Is Equipped With A Power Cord WARNING THIS APPLIANCE SHALLBECONNECTEDTOAMAINSSOCKETOUTLET WITH A P...

Страница 3: ...roduct herewith complies with the requirements of the Low Voltage Directive 2006 95 EC EMC Directive 2004 108 EC RoHS Directive 2002 95 EC WEEE Directive 2002 96 EC With regard to Directive 2005 32 EC and EC Regulation 1275 2008 of 17 December 2008 this product is designed produced and classified as Professional Audio Equipment and thus is exempt from this Directive Vice President of Engineering 8...

Страница 4: ...e Cat 5 fitted with a clip on ferrite sleeve STEWART TYPE 28A2029 0A0 near the network socket end This equipment must be earthed It should not be necessary to remove any protective earth or signal cable shield connections to prevent ground loops Any such disconnections are outside the recommended practice of BSS Audio and will render the EMC or safety certificate void If the unit is likely to unde...

Страница 5: ...ad they have OH short for off hook LEDs which illuminate when the phone is off hook Other indicators COM Communications The COM LED turns green to indicate a normal linked condition The COM LED blinks green if data is being transferred on the Ethernet or RS232 port The LED turns yellow if a link is established but no IP address has been established STAT Status The STAT LED turns green when a valid...

Страница 6: ...he destination to eliminate ground loop problems This means that the shield S connection on an input is grounded whereas the shield connection on an output is floating although connected via an internal network to ground for EMC compliance Balanced wiring The convention for balanced wiring 2 core plus shield is shown here Balanced cable Shield Hot Cold Unbalanced wiring The convention for unbalanc...

Страница 7: ... be provided by completing the loop and connecting the OUT port from the last device to the IN port of the first device in the chain All devices connected in the London BLU link chain must be configured for the same audio sample rate Analogue Input Output Connections 1 2 4 3 1 2 2 1 4 3 1 2 4 3 2 1 4 3 OUTPUTS INPUTS S S S S S S S S S S S S S S S S S S A B C D E TEL There are 10 analogue input con...

Страница 8: ... state or continuous controls such as Parameter Presets or faders See the help file within HiQnet London Architect for a table of resistor values for use with Parameter Presets or source selectors Two common ground connections are provided using the two C connectors to the left of the CONTROL INPUTS A 47kOhm log potentiometer Part no DM10018 connected between a control input and common will allow ...

Страница 9: ...200R unconnected lad supply 47kOhm log 10K 100kOhm linear switch 1k 1k 1k lad 1k ground 4k7 3 wire mode 470R OPTO Output In addition to the six standard LOGIC OUTPUTS there is an isolated output which fails safe open circuit if the unit becomes faulty ...

Страница 10: ... 20Hz to 20kHz A weighted 108dB unweighted CMRR 75dB at 1kHz Equiv Input Noise EIN 125dBu typ with 150 Ohms source Phantom power 48V nominal selectable per input A D Latency 37 Fs 0 77ms 48k AEC Up to 8 channels of AEC processing AEC Processing Latency 2385 Fs 49 69ms 48k Original 8k Algorithm AEC Processing Latency 1609 Fs 33 52ms 48k Full Bandwidth Algorithm Tail Length 200 ms Convergence Rate 4...

Страница 11: ...en devices Latency 11 Fs 0 23ms 48k Pass Through Latency 4 Fs 0 08ms 48k POWER AND DIMENSIONS Mains Voltage 100 240V AC 50 60Hz Power Consumption 55VA BTU Rating 188 BTU hr Operating Temperature Range 5 41 to 35 95 degrees C degrees F Dimensions HxWxD 1 75 45mm 1U x 19 483mm x 12 5 318mm Weight 9 1 lbs 4 1 kg BSS Audio incorporates high quality mechanical fans in some products All mechanical fans ...

Страница 12: ...plaint with the FCC if you believe it is necessary f The telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of the equipment If this happens the telephone company will provide advance notice in order for you to make necessary modifica tions to maintain uninterrupted service g If trouble is experienced with this equipment BLU 102 ...

Отзывы: