Motor-driven blocking device EasyBlocker
Installation
instruction
108320
3.3 Replace the bolt
If necessary, the bolt can be replaced. To do so, please proceed as follow:
1.
Disconnect the power supply from blocking
device.
2.
Dismount the blocking device from the door
frame (loose the two screws from cuff plate).
3.
Detach the housing lid - for this purpose keep
the housing horizontally, with lid on top. Instead
loose the six thermoplastic screws 2.5 x 10,
PZ1.
4.
Remove the old / defective bolt.
5.
Make sure, the bolt spring is in the correct
position. If necessary, the spring from the bolt
accessories can be used.
6.
Put the new bolt from behind in the corresponding duct in the housing. For this purpose lift the
motor on gearwheel side a little.
Attention:
The bolt can be put deeper in the housing,
so it sticks out from cuff plate. When the
power supply is switched on, the bolt will
automatically be moved in the position
„Open“.
7.
Please check that all parts are in correct position (bolt-spring, bolt, motor and motor-cable). Close
the housing lid again and tighten it by using the screws.
Attention:
Before the housing is closed, make sure the motor-cable lies correctly in the proper
duct and cannot be damaged by the housing lid !
8.
Switch on the blocking device power supply. The bolt will automatically be moved in the position
„Open“.
9.
Mount the blocking device into the door frame and attach the cuff plate.
Test the function of the blocking device.
Troubleshooting
The product is designed state-of-the-art. It needs to be thoroughly checked if the products is free from
material and functioning defects when it is leaving the factory.
Nonetheless, if any defects are occurring which cannot be repaired on site, please send us the defective
device including a detailed error description.
108320Err_ENG.doc
version 6.0a / 06.04.2016