12
3.2
A Closing I30, I60 or I100
1. Check that all the sealing surfaces are clean.
2. Brush the threads of the bolts clean, using a steel
wire brush.
3. Attach gaskets to the plates or check that all the
gaskets are properly attached.
Note!
If the gasket is wrongly positioned, it will show
by the fact that it rises out of the gasket groove or
that it is positioned outside of the groove.
4. Place the plastic tubes in the right order (marked
plastic end tubes are assembled last and mate
with front tubes). Lock with nuts.
5. Insert the plates with the herring bone pattern
positioned in alternate directions and with the
gaskets turned towards the frame plate.
Note!
Check and make sure all the plates are in the
correct order and aligned.
Step
Bolt No.
To dimension
1
1-2 or 3-4
1.10A
2
1-6 (I30) or
1-8 (I60 & I100)
A
6. Place the pressure plate on the plate package.
7. Lubricate the bolt threads with a thin layer of
grease, e.g. Gleitmo 800 or equivalent.
8. Tighten the tightening bolts alternatively and
diagonally in the sequence shown (1-2-3-4) to
1.10A. Be careful so that the frame plate and the
pressure plate are always in parallel, check and
make sure the measurements between them at
positions of bolts are 1.10xA during tightening.
Note!
Check again and make sure all the plates are
aligned.