2.2  Assembly of the counterpart 

The counterpart is assembled in the door leaf. It needs to be assembled in a way that the locking 
bolt  can  extend to the limit stop without contact. The maximum distance between the flange and 
the  counterpart  amounts  to  5 mm.  This  way,  it  is  guaranteed  that  the  locking  bolt  will  move  far 
enough into the counterpart. 

Assembly steps: 

1.  After having installed the blocking device, connect it to the test device (for the connection 

plan,  please  refer  to  chapter 3.1).  After  feeding  (e.g.  using  an  accumulator)  the  blocking 
device will open automatically. 

2.  Glue the assembly aid (adhesive felt) on the locking bolt of the blocking device and color it 

using an ink pad. 

3.  Close the door. 
4.  Lock  the  blocking  device  using  the  test  device.  The  locking  bolt  will  extend.  After  several 

locking trials the locking bolt will move back since it cannot reach the end position. 

5.  Open the locking device by using the test device. 
6.  Open the door. 
7.  On  the  door  leaf  you  can  recognize  a  color  circle  which  shows  the  exact  position  of  the 

counterpart. 

8.  Mark  the  center  using  a  center  punch  and  drill  the  hole  according  to  the  counterpart.  For 

the  installation  dimensions  of  the  counterparts,  please  refer  to  the  technical  data  sheet 
(also see chapter 6). 

9.  Assemble the counterpart. 
10.  Close  the  door  and  perform  a  functional  check  using  the  test  device  (also  refer  to 

chapter 3.3). 

Attention:  When  installing  the  blocking  device  on  an  emergency  fire  door,  please  check  which 

structural measures are allowed so that the door will not lose its certification! 

2.3  Emergency opening 

Electrical emergency opening: 
Guide the leads of the distribution voltage to a place which is accessible in case of a failure (e.g. 
behind the bell or the cover of the communicator, or others) in order to be able to use the electrical 
emergency opening options. By shortly interrupting and feeding the distribution voltage the bolt will 
be  moved  in  –  also  if  the  entrance  is  set  to  “Closed“.  Only  after  switching  over  the  entry  from 
“Opened“ to “Closed“ the bolt will be extended again. 
 

Содержание 108360.0

Страница 1: ...8360Err_en doc Version Page 1 Installation instruction Motor driven blocking device EasyLock 108360 VdS Class C G 107 102 ...

Страница 2: ... and communication of its contents is not allowed if it is not expressively allowed Any infringement obliged to compensation All rights reserved We have checked if the content of the printout complies with the described components Nonetheless we cannot exclude any deviations so that we do not take any liability for the complete compliance The information in this printout are regularly checked and ...

Страница 3: ...2 Installation 5 2 1 Assembly of the blocking device 5 2 2 Assembly of the counterpart 6 2 3 Emergency opening 6 3 Switching on 7 3 1 Connection to the test device 8322 0 7 3 2 Connection 8 3 2 1 Connection of several blocking devices 9 3 3 Commissioning 9 4 Trouble shooting 9 4 1 Electrical emergency opening 10 4 2 Mechanic emergency opening 10 4 3 Sluggish bolt 10 4 4 Replacing the bolt 11 4 5 P...

Страница 4: ... connection is performed using a 4 pin connecting cable Distribution voltage 12 V Distribution voltage 0 V Entry opened closed 0 V Bolt extends door locked open or 12 V Bolt moved in Exit status opened closed active 0 V with blocking bolt moved out Drive with statistic signal several blocking devices are connectable Feedback signal of the bolt position Easy installation in the door frame Only the ...

Страница 5: ...ce for a cable loop behind the hole for the blocking device or in the further cable duct so that sufficient cable reserves are available to extend the blocking device for service purposes The installation direction of the flange should be selected preferably in a way that the power on the bolt will come from the fixing screws of the blocking device also refer to figure 4 1 The exact installation d...

Страница 6: ...d position 5 Open the locking device by using the test device 6 Open the door 7 On the door leaf you can recognize a color circle which shows the exact position of the counterpart 8 Mark the center using a center punch and drill the hole according to the counterpart For the installation dimensions of the counterparts please refer to the technical data sheet also see chapter 6 9 Assemble the counte...

Страница 7: ... extended 8360Ans png Illustration 3 1 Connection plan blocking device Inputs and outputs of the blocking device Signal Lead color Description 12 V white Tension distribution 12 V 0 V brown Tension distribution 0 V Input green Input Closed 0 V Closed open or 12 V Opened Output yellow Open drain exit active 0 V Display of the status closed 3 1 Connection to the test device 8322 0 During the commiss...

Страница 8: ...esidual current of a view µA e g due to the corresponding burglary alarm center protective circuit varistors transildiods etc it may occur that the blocking device will not correctly react when changing over the output from active to inactive In order to work properly a pull up resistance can be put between the input and 12 V The amount of resistance shall not exceed 1 MΩ 8360ES2a png Illustration...

Страница 9: ...must neither contact nor interlock on the counterpart The locking bolt extends without several locking trials The locking bolt can extend at full length since otherwise it would open up again after several locking trials If the functionality is incorrect then check the wiring on the basis of the signal descriptions and the examples for switching on described in chapter 3 2 4 Trouble shooting In ca...

Страница 10: ...emergency opening If the electrical emergency opening options is not successful you can apply the mechanic emergency opening options Predetermine breaking point at the locking bolt The locking bolt of the blocking device possesses a predetermine breaking point which responds at a force of more than 1 kN about 100 kg at max 3 mm distance from the fixing flange Spare Locking bolts are available unde...

Страница 11: ... the blocking device refer to the drawing on the right The two guiding noses on the bolt need to fit exactly to the guiding grooves of the housing After a few seconds the bolt will be moved in If you put the bolt the other way around by mistake it will automatically be ejected after a few seconds When the bolt is correctly inserted turn in a new screw cap up to the stop 8360BA2 eps Illustration 4 ...

Страница 12: ...ad for min 5 sec Bolt path 12 mm Maximum distance housing flange to counterpart 8 mm for VdS Applications 3 mm Closing Opening time 0 3 s at 14 V DC operating voltage Locking force 5 N at 14 V DC operating voltage Admissible shearing force 1 0 kN at max 3 mm distance from the flange 0 5 kN at 8 mm distance from the flange Operating temperature Storage temperature range 25 C 60 C 40 C 70 C Ecologic...

Отзывы: