11
mentary status/alternative key-switching
8 dark/flashing (bit Zone8T = 0/1) zone
8 as trouble/tamper
5.1.5. If button 5 is pressed, record of zones
for the first user area is available:
Alternative, pressing of button from 1 to 8
follows by flashing of LED between 1 and 8
(corresponding to zones between 1 and 8).
When corresponding LED flashes, the zone is
connected to first user area, but dark LEDs cor-
responding zones are connected to second
user area. Connection of all zones to the area
of the second user is incorrect and forbidden.
Two users can be connected to the system.
Every user has 8 access codes and only one
Master code. If only the zone 8 (keyboard
tamper) is used by the second user, the sys-
tem can be armed and disarmed by all 16 ac-
cess codes. The green LED Mode flashes, but
not permanently if the system is in armed
mode. To quit this mode press, once more but-
ton PRG or other functional button.
5.1.6. If button 6 is pressed zones test