Symptom
Possible cause
Actions
Transmitter power set too
low.
•
Adjust the
However, if the CNR falls as you increase the
power of the transmitter, more power is not
the solution.
•
CNR is dependent on frequency band.
Typically, a good CNR at 1.4 GHz is
25
–30 dB, at 2 GHz is 23–27 dB, and at
7 GHz is 20
–25 dB
Transmitter settings
incorrect.
•
Check the transmitter’s audio settings,
including analog, SDI embedded, Mic/Line
and phantom power.
Reset the software
If the software hangs, you can do a quick reset which closes and restarts the receiver’s software functions. If
you are resetting the software to work around an issue, insert a memory stick containing a diagnostic log file
into the USB port in the front panel. When you reset the software, details of where the software stopped
working are saved onto the memory stick. Contact BSI Support for more information.
To reset the receiver software, follow these steps:
1. From the main menu, select
Settings
and then select
Software Reset
.
2. Press
OK
to select
Quick Reset
.
3. Press
OK
again to reset the software.
Reboot the receiver
If you cannot easily access the power socket on the rear panel of the receiver, you can use the
reboot option to power cycle the receiver. You may need to do this during a
To reboot the receiver, follow these steps:
1. From the main menu, select
Settings
and then select
Software Reset
.
2. Select
Reboot
.
3. Press
OK
to reboot the receiver.