HEAT  ONLY

WALL HUNG GAS BOILER FOR

CENTRAL HEATING SUPPLY

Please Read Instructions Carefully

Save for Future Reference

Do not store or use gasoline or other fl ammable vapors and liquids 

 

in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

 

Do not try to light any appliance.

• 

Do not touch any electric switch; do not use any phone in your 

• 

building.
Immediately call your gas supplier from a neighbor’s phone. Fol-

• 

low the gas supplier’s instructions.
If you can not reach your gas supplier call the fi re department.

• 

Installation and service must be performed by a qualifi ed installer, 

 

service agency or the gas supplier.

WARNING: If the information in this manual is not followed 
exactly, a fi re or explosion may result causing property dam-
age, personal injury or loss of life.

SAVIO HEAT ONLY USER MANUAL

Содержание Savio

Страница 1: ...appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Fol low the gas supplier s instructions If you can not reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in this manual is not foll...

Страница 2: ...those we specify The installing contractor is the best judge of a system s speci c requirements as well as the local availability of certain makes and models of controls and accessories The preceding does not apply however to the equipment that comes with every boiler such as the overheat control and pressure relief valves The installation of the speci c devices supplied with every boiler is absol...

Страница 3: ...nce Description 3 9 Operation Lights 4 10 Instructions for Use 5 11 13 Warnings 5 1 11 Re lling Procedure 5 2 11 Lighting Operation Instruction 5 3 12 Central Heating Circuit Temp 5 4 12 13 Extinguishing Instructions 5 5 13 Useful Advice 6 14 16 Central Heating 6 1 14 Frost Protection 6 2 14 Periodic Maintenance 6 3 14 External Cleaning 6 4 15 Operational Faults 6 5 15 16 Warranty 18 ...

Страница 4: ...alified service technician to inspect the boiler and to replace any part of the control system and any gas control which has been under water Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your build ing Immediatel...

Страница 5: ...re often confused with those of in uenza and the highest incidence of poisoning occurs at the onset of cold weather or during u season A victim may not experience any symptoms only one symptom or a few symptoms Suspect the presence of carbon monoxide if symptoms tend to disappear when you leave your home The following signs may indicate the presence of carbon monoxide Hot gasses from appliance ven...

Страница 6: ...e boiler area clean and free of all fire hazards Please read the literature and warranties supplied by the manufacturers of the various accessory equipment This equipment is warranted by the respective manufacturers not by BOYERTOWN Each piece of equipment must be installed and used according to the recommendations of the manufacturer Codes and Regulations Installation of the boiler and related eq...

Страница 7: ... in the system Frost protection contains an integral frost protection system to prevent frost dam age which can occur in areas susceptible to very cold weather conditions Boiler operation recognition system should the boiler not be used for longer than 24 hours it then performs a control led system test to ensuring the motorized components within the boiler do not be come inoperable due to lack of...

Страница 8: ...0 8 5 3 2 4 Propane inwc 1 4 9 0 5 2 FLUE DESIGN Minimum Venturi pressure inwc 0 64 Flue pipe diameter Coaxial in 2 25 4 3 25 5 Twin split pipes in 3 25 3 25 Nominal heat ow rate 0 2000ft MBH 122 8 Nominal heat ow rate 2000 4500ft MBH 116 7 Min Exhaust temperature F 262 Max Exhaust temperature F 324 INJECTORS No Size Natural 14 130 Propane 14 89 GAS FLOW RATE Gas Min Max Natural ft h 48 7 121 1 Pr...

Страница 9: ...ting circuit temperature and pressure gauge 5 Lock out signal lamp 6 Boiler reset button 7 Function switch and Central heating temperature adjustment knob 8 Appliance operation lights 1 2 3 8 7 6 5 4 Piping Connections 3 3 9 C h PRV discharge pipe 10 Central heating ow pipe 11 Central heating return pipe 12 Gas inlet pipe Figure 3 1 Figure 3 2 Figure 3 3 ...

Страница 10: ...on Anti freeze system active 1 second pulse every 2 seconds normally operating boiler Function selector in on position Central heating operation Frost protect operation Faulty central heating temperature probe NTC Faulty primary circuit no water or absence of ow Lack of burner ignition no ignition signal from the full se quence ignition device Ignition gas pressure adjustment Minimum gas pressure ...

Страница 11: ...ith a built in anti freeze system that operates the boiler when the temperature is below 41 F Therefore when the boiler is not lit or used in cold weather with consequent risk of freezing do not switch off the boiler at the circuit breaker or close the gas inlet cock When you expect not to use the boiler for a long period follow the instructions given in sec tion 5 5 on page 13 Refilling procedure...

Страница 12: ...ash every 2 seconds operating boiler 4 If the appliance will not operate follow the extinguishing instructions on page 13 and call your service technician or gas supplier Central Heating Circuit Temperature 5 4 1 The output temperature of c h water is adjustable from a minimum of about 100 F to a maximum of about 176 F Figure 5 3 by turning the knob B 2 Adjustment of the boiler temperature al ters...

Страница 13: ...23 F From 41 to 59 F Between 23 and 41 F Extinguishing Instructions 5 5 To turn the boiler off set the function se lector B to the position shown in the Fig ure 5 5 The appliance operation light A gure 5 2 will ash every 4 seconds stand by mode Turn off electric power to the appliance at the circuit panel of boiler serviceman s switch Figure 5 5 B When you expect not to use the boiler for a long p...

Страница 14: ...ng system In the case that the external temperature may be lower than 32 F it is suggested to leave the system running setting the room thermostat at a low temperature When the boiler is completely switched off for a long period it is recommended to empty completely central heating circuit Periodic Maintenance 6 3 For ef cient and continuous operation of the boiler it is advisable to arrange maint...

Страница 15: ...tion and then press the boiler reset button 2 Fig 6 2 For the rst light up and following main tenance procedures for the gas supply it may be necessary to repeat the resetting operation several times so as to remove the air present in the pipework Figure 6 2 2 1 B If noises due to air bubbles are heard during operation You should check that the pressure on the temperature and pressure gauge Fig 5 ...

Страница 16: ...that this does not happen and to de crease the pressure to a normal value it is advisable to vent some of the water in the appliance through the bleed valves present in the heating system Figure 6 3 If water should occasionally leak from the boiler Close the cocks connected to the inlet gas pipe and to the supply cold water inlet pipe under the boiler and call an Authorised Service Person In case ...

Страница 17: ...WN PA freight pre paid BOYERTOWN and SAVIO will not be responsible for 1 Components that are part of the heating system but were not manufactured by SAVIO or BOYERTOWN as part of the boiler 2 The workmanship of the installers of SAVIO boilers Furthermore this warranty does not assume any liabil ity for unsatisfactory performance caused by improper installation 3 Any costs for labor to remove or re...