10 SAVIO FP USER MANUAL
Operation Lights
4.
Three lights (8 in Fig. 3.2) give detailed indication regarding the operation of the boiler.
The following table gives the relationship between each of the possible light combinations and
their meaning.
A short pulse every 4 seconds: stand-by condition Function
selector in
position. Anti-freeze system active
1 second pulse every 2 seconds: normally operating boiler.
Function selector in on position
Central heating operation
Frost protect operation
Faulty central heating temperature probe NTC
Faulty primary circuit (no water or absence of
fl
ow)
Lack of burner ignition (no ignition signal from the full se-
quence ignition device)
Ignition gas pressure adjustment
Minimum gas pressure adjustment
Lamp OFF
Lamp ON
Flashing lamp, alone
or simultaneously
with another lamp.
Flashing lamp, al-
ternate with another
lamp