STEP 3 - Connect the battery charger to Mains Power (240Vac) 

 

Connect the battery charger to a 240VAC Mains Powered socket. 

 

The Charger will automatically start when AC power is connected and switched on. 

  (Note: If the Fault Indicator LED illuminates Red, please check your connections as it’s likely that 
the  Positive  and  Negative  Leads  are  reversed.  Refer  to  Trouble  Shooting  Page  for  further 
information) 

 

Select the desired charge rate: 

1A, 2A or 4A

 

Select the correct Battery Type: 

o

 

Calcium type

  is  the new generation battery type: Sealed Type  (VRLA)  Lead Acid 

Battery with Calcium Content (Automotive or Deep Cycle) 

o

 

AGM/Wet type 

is the most common battery type also known as WET (Flooded) or 

AGM  (Absorbed  Glass  Mat)  Sealed-valve  regulated  Lead  Acid  (VRLA)  Batteries 
(Automotive or Deep Cycle)

 

o

 

GEL  type 

is  the  Sealed  type  (VRLA)  with  a  jellified  electrolyte  (Automotive, 

Aviation , Solar, Deep Cycle)

 

 

WARNING

:  Please  ensure  the  correct  Battery  Type  is  selected.  Do  not  charge  using  an  incorrect 

Battery  Type  Setting.  (Do  not  charge  a  Gel  Battery  with  Calcium  Battery  selection  as  this  may 
damage your battery) 

Note: The charger will automatically memorise your charging rate setting and battery type setting. The next time you use 
the charger it will automatically start with the last settings. 
We strongly recommend that you refer to the battery manufacture’s specifications when selecting the charge rate and 
battery type. 

 

THE CHARGING PROCESS:

 

 

The charging stages are as follows:

 

 

Soft  start

:  Charge  the  battery  using  half  the  maximum  current  until  the  battery  voltage  is  over 

10.5V. (Soft Start occurs if the initial voltage is less than 10.5V due to deep discharge)

Indicated 

by the Blue Charging LED Flashing

 

Bulk Charge

: Charge using a constant maximum current until the battery rises to the absorption 

level.

Indicated by the Blue Charging LED ON

 

Absorption

:  This  stage  charges  the  battery  using  a  constant  voltage  providing  that  the  Battery 

voltage is over 85%. The Charging Voltage for this stage is determined by the Battery type selection: 

Содержание BS40

Страница 1: ...ER For lead acid batteries User Manual and Guide to professional battery charging for Starter and Deep Cycle batteries THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS FOR 12V BATTERY...

Страница 2: ...the connections to the battery Connection to supply mains has to be in accordance with National wiring rules Battery acid is corrosive Rinse immediately with water if acid comes into contact with ski...

Страница 3: ...put short circuit occurred and prevents any damage Reverse polarity protection The charger can automatically shut off when the output polarity reversed and without damage Never overcharge your battery...

Страница 4: ...s as described in this manual SHORT CIRCUIT PROTECTION The charger has reverse battery and short circuit protection If a reverse battery or charger output lead short condition exists Red LED flashes w...

Страница 5: ...the vent caps and add distilled water so the levels are halfway between the upper and lower fill lines Check the Voltage Output Switch on the charger and make sure it s on the correct voltage Part Nu...

Страница 6: ...icle determine if the vehicle is positively or negatively earthed o If Negatively Earthed Most Common FIRST Connect the Red battery charger lead to the positive Battery post and then connect the Black...

Страница 7: ...correct Battery Type is selected Do not charge using an incorrect Battery Type Setting Do not charge a Gel Battery with Calcium Battery selection as this may damage your battery Note The charger will...

Страница 8: ...life We recommend that you periodically use this rejuvenation De Sulphate feature to ensure you get the maximum life out of your battery To activate this rejuvenation feature simply press and hold the...

Страница 9: ...ossible As they may need topping up with distilled water after charging LED STATUSINIDICATOR TABLE 1 Charging Rate Selection Button Press Mode to Select the Current Charge Rate 2 Charging Current LED...

Страница 10: ...ror Blue Green Yellow Red A C Power connected battery disconnected OFF OFF OFF OFF Manual Rejuvenation charging OFF OFF FLASH OFF Soft Start charging FLASH OFF OFF OFF Bulk charging ON OFF OFF OFF Abs...

Страница 11: ...ours soft start timer reached 24 hours bulk charge timer reached Check the charging rate and battery type selection matches the battery Battery cannot be charged and must be replaced Abnormal LED indi...

Отзывы: