REPLACING FUSES IN THE MPS2 POWER SUPPLY

CAUTION: These service instructions are for use by qualified service personnel only. To reduce the risk of 

electric shock do not perform any servicing other than that contained in the operating instructions unless you 

are qualified to do so. 

All fuses are 5mm x 20mm, time lag type and are accessible only by removing the top cover.  When 

replacing fuses, disconnect the power cord before opening the unit!

Recommended replacement fuses:

100V~ models: T 2.5A L 250v  Littlefuse 218 02.5

110V~ models: T 2.0A L 250v  Littlefuse 218 002

 

 

120V~ models:

 

T 2.0A L 250V  Littlefuse 218 002

  

 

200V~ models: T 1.25A L 250v Littlefuse 218 1.25

 

 

220V~ models: T 1A L 250v 

Littlefuse 218 001

  

 

230V~ models: T 1A L 250v 

Littlefuse 218 001

 

 

240V~ models: T 1A L 250v 

Littlefuse 218 001 

 

 

 

Содержание MPS-2

Страница 1: ...MPS2 For use with preamp models BP26 BP26DA BP26MC BP26P BP1 5 and 10B EPS crossovers POWER SUPPLY OWNER S MANUAL ...

Страница 2: ...ing defects for twenty 20 years from the original date of manufacture The warranty includes parts and labour Bryston Digital circuits and cables are warranted for five years from the original date of manufacture The warranty includes parts and labour Bryston products having motorized moving parts excluding motorized volume controls are warranted for three years from the original date of manu factu...

Страница 3: ...te trigger outputs may also be turned on On the rear of the unit there are five 2 pin terminal blocks that provide control signals for remote on off functions Plug in screw adjust terminal blocks are provided for all 5 of these connectors These terminal blocks accept bare wires between 12 and 26 AWG Insulated wires should be stripped to expose 3 inches 5 16 or 8mm of bare wire Use a small blade sc...

Страница 4: ...ted to one of the 4 MPS2 outputs is turned on and NOT muted a control sig nal of 12Vdc will be present on the respecitve SWITCHED TRIGGER OUTPUT pins of the of the MPS2 power sup ply This control signal can be used to turn on suitably equipped amplifiers and other equipment POWER SUPPLY CORD Use only power sup ply cords supplied by Bryston Ltd to connect the MPS2 power supply to other Bryston equi...

Страница 5: ...cables such as those shown shown below It is important to use the correct power supply cable WARNING The connector terminals of main outputs 1 2 3 4 on the MPS2 power supply rear panel are HAZARDOUS LIVE and present a risk of electric shock Use only preassembled power inter connect cables provided by Bryston for connection of these terminals ...

Страница 6: ... All fuses are 5mm x 20mm time lag type and are accessible only by removing the top cover When replacing fuses disconnect the power cord before opening the unit Recommended replacement fuses 100V models T 2 5A L 250v Littlefuse 218 02 5 110V models T 2 0A L 250v Littlefuse 218 002 120V models T 2 0A L 250V Littlefuse 218 002 200V models T 1 25A L 250v Littlefuse 218 1 25 220V models T 1A L 250v Li...

Отзывы: