background image

recording output. This feed is unaffected by the opera-

tion of other front panel controls. 

   Tape Inputs:  

The “FROM TAPE” (unbalanced RCA) 

inputs are useful for monitoring tape playback or pro-

cessed signals. Moving the “Tape/Normal” toggle to 

Tape’ (up) position monitors the recorded signal on 

recorders equipped with a separate playback head, 

or the processed signal when using a signal proces-

sor. Input sensitivity is 500mv, input impedance is 10K 

ohms.

PHONO EQUALIZATION MODULE 

(Optional)

(Optional)

:

   Bryston’s phono equalizer circuitry is available in both 

B60 and B60R integrated amplifiers.  It features highly 

accurate equalization, extremely low noise and distortion 

and  provides  headroom  margins  sufficient  to  prevent 

overload from any known phono source. If your turntable 

provides a separate ground lead , system noise may be 

minimized by connecting it to the ground post adjacent 

to the phono inputs on the rear panel.  Input impedance 

is 50K ohms and sensitivity is 5mV.

DIGITAL AUDIO INPUT MODULE 

(Optional)

(Optional)

:

   The B60DA / B60RDA models contain an SPDIF 

compatible digital audio input (RCA jack). To select this 

input set the rotary “SELECTOR” switch to the “DAC” 

position. Once this input is selected operation of the 

digital-to-analog convertor is fully automatic. The digital-

to-analog convertor can handle input sample rates from 

16KHz to 108KHz, and word lengths of 16, 18, 20 or 24 

bits.

FRONT PANEL CONTROLS:

VOLUME CONTROL:

Rotary control varies the out-

put level to the ‘MAIN OUTPUTS’, (does not effect ‘TO 

TAPE’ outputs). BALANCE: Rotary control adjusts the 

left-versus-right channel levels. 

BALANCE CONTROL: 

BALANCE

BALANCE

 is a tailored-inflection type 

which has very gradual action near the center of  rota-

tion allowing fine adjustments to the stereo image. 

For convenience the electrical center of the control is 

detented. 

SOURCE SELECTOR SWITCH:

SELECTOR

SELECTOR

  

Rotary switch deter-

mines which input will appear at the “TO TAPE” outputs 

for recording or processing, as well as determining 

which program is available at the Main outputs. (When 

the “TAPE/NORMAL” switch is in “Tape” position, 

“FROM TAPE” inputs appear at Main Outputs). 

TAPE/NORMAL SWITCH:   “

Normal

 position monitors 

 position monitors 

whichever input is selected at the rotary SELECTOR 

switch. “Tape” position provides monitoring of the 

“FROM TAPE

 input for A/B comparison with the 

””

source. Should an external processor or equalizer be 

connected in the tape loop, the ‘TAPE / NORMAL” 

switch will act as an in/out switch for the external equip-

ment. 

LOUDSPEAKER OUTPUTS:

   Output connectors consisting of two pairs of red/

black 5-way binding posts, which can accept standard 

banana plugs, spade lugs, pins or bare wire. Since the 

binding posts are gold plated we recommend gold plat-

ed connectors also be used on the speaker cables for 

optimum long term low distortion performance. we also 

recommend that loudspeaker wire of at least 16 gauge 

be used for maximum performance.

B60 REMOTE CONTROL

The Bryston B60 includes a hand 

held  remote  control  unit.  It  pro-

vides  for  remote  volume  control 

and  full  signal  mute.  the  Volume 

control  is  a  motor  driven  design. 

This  approach  ensures  lower  dis-

tortion  and  other  noise  artifacts 

than VCA’s and DAC’s.

Pressing  the  MUTE  button  on 

the  remote  control  will  fully  mute 

the  output  from  the  preamplifier 

section.  The  power  LED  on  the 

front panel will turn from green to 

red. To un-mute the amplifier sim-

ply push the MUTE button again or 

press the volume UP button.

The mute function on the remote 

control will not function if using headphones.

   The  hand  held  remote  unit  is  battery  operated.  To 

change  the  battery  remove  the  bottom  cover  plate  by 

unscrewing the Philip’s head screws and replace the 9 

volt  battery  carefully  observing  the  polarity  of  both  the 

battery and battery clip.

   We  recommend  maintaining  a  direct  line-of-sight 

between the hand held remote and the front of the B60R 

to ensure the most efficient operation of the remote fea-

tures.

B60 INTEGRATED AMPLIFIERS

2

Содержание B60R

Страница 1: ...INTEGRATED AMPLIFIER OWNER S MANUAL for Models B60R B60RP B60RDA B60R...

Страница 2: ...ug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience recep tacles...

Страница 3: ...e jumpers Simply pull the two U connectors straight out with the power to the amplifier turned OFF Store them in a safe place for future use These pre out power in connec tors provide for complete sep...

Страница 4: ...hich input will appear at the TO TAPE outputs for recording or processing as well as determining which program is available at the Main outputs When the TAPE NORMAL switch is in Tape position FROM TAP...

Страница 5: ...106dB gwlow full output SLEW RATE 60v uSec DAMPING FACTOR 500 at 20Hz 8 ohms POWER BANDWIDTH 0 5Hz to over 100KHz SENSITIVITY 775v INPUT IMPEDANCE 50K ohms ADDITIONAL SPECIFICATIONS for B60DA B60RDA...

Страница 6: ...B60 INTEGRATED AMPLIFIERS 4...

Страница 7: ...air centers for return authorization Products must be returned using original packaging material only Packing material may be purchased from Bryston if necessary This warranty is considered void if th...

Страница 8: ...op cover CAUTION When replacing fuses disconnect the power cord and all other cables from the B60 before opening the unit Recommended replacement fuses for 100 120VAC models Littlefuse 218 315 Bussman...

Отзывы: