Bryston 3BSST2 Скачать руководство пользователя страница 5

FRONT PANEL

1

.  POWER SWITCH

The front panel label             is a push-on/push-off type push-button power switch used to apply or remove a/c line 

power to the 

SoftStart

 circuitry. Note that the rear circuit breaker must be on for the amplifier to power-up.

2. L

·

E

·

D INDICATORS

Each SST

2

 channel has a LED indicator to monitor the following conditions:

 

U

nlit

  - 

 

indicates channel has no power.

 

R

ed

  - 

 

indicates channel is muted (power-up)

 

G

Reen

  -

            indicates channel operation is normal.

 

F

lashinG

 R

ed

 

-  indicates channel clipping.

 

O

RanGe

 -

 

indicates channel thermal shutdown.

POWER UP SEQUENCE 

After pushing the power switch (

 in the picture above), each channel LED will turn from unlit to red (mute). 

When the power supplies have stabilized the channel will come out of mute and the LED will change to green 

(normal operation).

UNLIT L

·

E

·

D  ( No power )

The SST

2

 channel LED when unlit indicates no A/C mains power is present at the channel. If both channel LED 

indicators are unlit the amplifier probably needs only to be powered on.

CLIPPING  ( flashing red )

Clipping occurs when the channel output level no longer can follow the level increase at the input (Over driven 

input condition). When an SST

2

 channel is driven into clipping the channel LED will change from green to red 

then back to green when the level is reduced ( Flashing Red ). Momentary clipping can be tolerated, however 

it indicates that maximum undistorted power has been surpassed and potential speaker damage may result 

if overload conditions persist. Any amplifier that is constantly operated into clipping indicates a more powerful 

amplifier is needed for that application.

THERMAL SHUTDOWN ( orange )

Each channel has thermal shutdown circuitry to prevent damage due to overheating.  Should thermal shutdown 

occur, the channel will mute, and the channel LED will turn orange indicating this condition. When the channel 

has cooled to a safe operating condition the channel will return to normal operation. Persistent Thermal shut-

down indicates steps need to be taken to increase airflow across the channel or channels heat sink. ( Also see 

installation section on ventilation ).

N.B. 

In some markets the LED indicators, which are  normally red/green, may be red/blue instead. When red/blue 

LEDs are supplied green is replaced with blue and orange is replaced with magenta in the above descriptions.

Содержание 3BSST2

Страница 1: ...3BSST2 4BSST2 OWNER S MANUAL ...

Страница 2: ... manufacturing defects for twenty 20 years from the original date of manufacture The warranty includes parts and labour Bryston digital products and cables are warranted for five years from the original date of manufacture The warranty includes parts and labour Bryston products having motorized moving parts excluding motorized volume controls are warranted for three years from the original date of...

Страница 3: ...t Panel Page 2 Power Switch LED Indicators Rear Panel Inputs Outputs Page 3 Input Select Switch Balanced Input Connector Single ended Input Connector Input Sensitivity Switch MODE Switch Bridged vs Individual mode Level Control Outputs Binding Post Connectors Circuit Breaker Page 4 A C Power Inlet External Control Voltage Power Up Bridged Mode Page 5 Technical Specifications Page 6 3BSST2 Exterior...

Страница 4: ...ed then additional forced air cooling may be necessary Bryston can provide an optional fan package if required Any SST2 channels thermally shutting down during operation indicates insufficient air flow and a remedy must be found for cooling the amplifier Provide a minimum 6 space to the rear of the amplifier for ventilation and dressing cables to and from the amplifier Never operate the amplifier ...

Страница 5: ...ut level no longer can follow the level increase at the input Over driven input condition When an SST2 channel is driven into clipping the channel LED will change from green to red then back to green when the level is reduced Flashing Red Momentary clipping can be tolerated however it indicates that maximum undistorted power has been surpassed and potential speaker damage may result if overload co...

Страница 6: ...se 113 dB The noise is referenced in dB below rated output Different input configurations result in slightly different noise read ings The above noise ratings represent minimum readings actual readings may be better 5 MODE SWITCH individual or bridge mode The individual setting is for two channel operation Bridge mode is for mono operation 6 LEVEL CONTROL PRO models only The level control will att...

Страница 7: ...source device and the SST2 amplifier The appropriate mating connector Bryston part number 110A 11104 is supplied with each amplifier Set the External Turn On switch to External The ampli fier will now power up only when the control voltage is present on Immediately following power up the con trol voltage will appear at the OUT terminals of connec tor for the control of other equipment The removal ...

Страница 8: ...ncreased heat that is generated It should noted that the usual minimum load connected to a pair of bridged 3B or 4B channels should be twice the minimum of 4 Ohms or 8 Ohms Only one input is used Channel 1 also referred to as the LEFT input The single input can be either balanced or un balanced Only the two RED binding post connectors are used i e the black ones are NOT used The LEFT Ch 1 binding ...

Страница 9: ... Hr Bridged 450W 8 ohms 1053 Watts Max Heat Dissipation 2057 Btu Hr Power Output 300 watts per channel into 8 ohms 500 watts per channel into 4 ohms Gain 29dB position 28 28V V 23dB position 14 14V V Sensitivity High 1 0Vin 100W out with an 8Ω load 1 8Vin 300W out with an 8Ω load Low 2 0Vin 100W out with an 8Ω load 3 6Vin 300W out with an 8Ω load Input Impedance Individual mode Single ended 60K Oh...

Страница 10: ......

Страница 11: ......

Страница 12: ...300006 3 BRYSTON LTD 677 NEAL DRIVE P O BOX 2170 PETERBOROUGH ONTARIO CANADA K9J 7Y4 2011 07 20 ...

Отзывы: