Bryggerne BM-S300M-1 Скачать руководство пользователя страница 5

1. First set up the pump connection pipe.  
2. Before switch on the pump, make sure the device had been filled with water.  
3. Dry running the pump is forbidden, it will damage the pump if working without water go through.  
4. Circulation is not necessary in boiling process. Please do not switch on the pump while the device 

carry on boiling. 

5. If the pump stop working, it may be blocked by residue. Please switch off the machine and un-

plug it. Make sure there is no liquid in the device, and machine had been cool down,  then open 
the underneath plastic cover. Take the pump out, un-screw it and remove the residue.  

6. The pump should be cleaned after used immediately incase of the wort stay inside of it and get 

dry.  

7. Use luke-warm water to go through it for 5-10mins after each brewing until you make sure inside 

is cleaned.  

Maintain The Device 

1. Cleaning 

The device must be cleaned immediately after the brewing process. Avoid surface drying of wort and 
malt remnants, as this will significantly impair the cleaning process. All stainless steel components 
can be cleaned using a conventional detergent. Abrasive agents and sponges/brushes that cause 
scratching are not suitable. Ideally use a pipe cleaner thread to clean the bottom element part. When 
cleaning the brewing vessel ensure that no water spray or moisture comes into contact with the 
electrical components. The Plug must be protected for performing cleaning activities. Before starting 
the brewing process, remove all dust and dirt from the device and all internal fitting by means of 
warm water. Also rinse the pump and lines by means of transfer pumping. Caution: Never run the 
pump without water. The valve also need to be cleaned, all the components like water pipe, cover 
and false bottom had to be cleaned, as these could have a negative impact on the foam stability of 
the beer if with dirt on. 

2. Storing 

The device must be sorted in dry location. Avoid contact with ferrous or rusty objects.  

Signal of PCB 

E1: 

Sensor is open circuit 

E2: 

Sensor is short circuit 

C1:

 Press "-" and "+" at the same time, for temperature correction. Temperature correction range is 

from -10

 to +10

.  

Correct Disposal of this product

This  marking  indicates  that  this  product  should  not  be  disposed  with  other 
household  wastes  throughout  the  EU.  To  prevent  possible  harm  to  the 
environment  or  human  health  from  uncontrolled  waste  disposal,  recycle  it 
responsibly to promote the sustainable reuse of material resources. To return 
your used device, please use the return and collection systems or contact the 
retailer  where  the  product  was  purchased.  They  can  take  this  product  for 
environment safe recycling. 

 

Содержание BM-S300M-1

Страница 1: ...r future further reference Do not use the device if the cord or plug is damaged It should be replaced before used Do not use a multi sockets as power output of this device is too high Overloading the electric diffuse must be avoided As the device requires extra power do not use the same fuse to protect other Large Consumers Check the products rating label and make sure the water urn voltage is fit...

Страница 2: ...brewing equipment it is very important for brewing and get the good beer 2 Install the over flow pipe Over flow pipe components long pipe 1 short pipe 1 two thread connector 2 one thread connector 1 extend connector 1 pipe s cap 1 There are two pipes for different volume of grain You can combine them together by two thread connector as below image After assembling the over flow pipe screw the over...

Страница 3: ... time normally is 60mins 11 Put the cooling coil inside the wort 5mins in advance before the boiling is done It s for disinfection purpose 12 Let the cold water go through the coil until the wort reached to 20c as fast as possible 13 Then you can transfer the wort to fermentation bottle Please clean the fermentation bottle before used Add the yeast according to receipt Fermentation temperature and...

Страница 4: ... in case of the program directly enter in step 4th Tips Sparging water temperature is about 72 1 5 5 The fourth step is for fierce boiling for 30mins The stronger power you set the boiling will be more intense 1 5 6 The fifth step is for weak boiling the lower power you set the boiling will be more gently but if the power is too low the wort can not be reached to boiling temperature due to the hea...

Страница 5: ...n the bottom element part When cleaning the brewing vessel ensure that no water spray or moisture comes into contact with the electrical components The Plug must be protected for performing cleaning activities Before starting the brewing process remove all dust and dirt from the device and all internal fitting by means of warm water Also rinse the pump and lines by means of transfer pumping Cautio...