1. First set up the pump connection pipe.
2. Before switch on the pump, make sure the device had been filled with water.
3. Dry running the pump is forbidden, it will damage the pump if working without water go through.
4. Circulation is not necessary in boiling process. Please do not switch on the pump while the device
carry on boiling.
5. If the pump stop working, it may be blocked by residue. Please switch off the machine and un-
plug it. Make sure there is no liquid in the device, and machine had been cool down, then open
the underneath plastic cover. Take the pump out, un-screw it and remove the residue.
6. The pump should be cleaned after used immediately incase of the wort stay inside of it and get
dry.
7. Use luke-warm water to go through it for 5-10mins after each brewing until you make sure inside
is cleaned.
Maintain The Device
1. Cleaning
The device must be cleaned immediately after the brewing process. Avoid surface drying of wort and
malt remnants, as this will significantly impair the cleaning process. All stainless steel components
can be cleaned using a conventional detergent. Abrasive agents and sponges/brushes that cause
scratching are not suitable. Ideally use a pipe cleaner thread to clean the bottom element part. When
cleaning the brewing vessel ensure that no water spray or moisture comes into contact with the
electrical components. The Plug must be protected for performing cleaning activities. Before starting
the brewing process, remove all dust and dirt from the device and all internal fitting by means of
warm water. Also rinse the pump and lines by means of transfer pumping. Caution: Never run the
pump without water. The valve also need to be cleaned, all the components like water pipe, cover
and false bottom had to be cleaned, as these could have a negative impact on the foam stability of
the beer if with dirt on.
2. Storing
The device must be sorted in dry location. Avoid contact with ferrous or rusty objects.
Signal of PCB
E1:
Sensor is open circuit
E2:
Sensor is short circuit
C1:
Press "-" and "+" at the same time, for temperature correction. Temperature correction range is
from -10
℃
to +10
℃
.
Correct Disposal of this product
This marking indicates that this product should not be disposed with other
household wastes throughout the EU. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, recycle it
responsibly to promote the sustainable reuse of material resources. To return
your used device, please use the return and collection systems or contact the
retailer where the product was purchased. They can take this product for
environment safe recycling.