background image

Location of Controls

Page 3

MODE SWITCH

Heat, Cool or Off

On or Auto

FAN SWITCH

UP & DOWN
BUTTONS

72

Содержание TSTATBBNQ001

Страница 1: ...at 1 Cool Easy Slide Switch Operation USERS INFORMATION MANUAL M O D E L T S T A T B B N Q 0 0 1 N O N P R O G R A M M A B L E D I G I T A L T H E R M O S T A T NOTE TO INSTALLER This manual must be l...

Страница 2: ...PLAY NORMAL OPERATION PREPARATION REMOVE OLD THERMOSTAT WIRE CONNECTIONS JUMPER CONFIGURATION TEST OPERATION TROUBLESHOOTING WARRANTY 2 4 5 6 7 10 17 20 21 INSTALLATION AND BATTERY REPLACEMENT 8 24 Br...

Страница 3: ...en is displayed the batteries must be replaced immediately The manufacturer cannot be liable for improper operation of the thermostat if the batteries are not immediately replaced The annual battery r...

Страница 4: ...Location of Controls Page 3 MODE SWITCH Heat Cool or Off On or Auto FAN SWITCH UP DOWN BUTTONS 72...

Страница 5: ...ostat will show the desired Set Temp temperature indicator Once this screen is reached you may use the Up or Down arrow buttons to adjust the desired room temperature After five seconds with no button...

Страница 6: ...itched to auto In fan auto the fan will turn on only with a heat or cool demand When Fan On is selected the fan will run continuously even when the mode switch is set to Off Adjust the desired set tem...

Страница 7: ...the Heating Air Conditioning system at the main fuse panel Most residential systems have a separate breaker for disconnecting power to the furnace Proper installation of the thermostat will be accompl...

Страница 8: ...way Disconnect the wires from the old thermostat Tape the ends of the wires as you disconnect them and mark them with the letter of the terminal for easy reconnection to the new thermostat Keep the ol...

Страница 9: ...the top forward until the pins release and then lift the bottom out SCREWDRIVER SLOTS The batteries must be replaced immediately when the thermostat displays the Low Battery code fig 1 FIG 1 To Open...

Страница 10: ...LACE WITH ALKALINE BATTERIES AT LEAST ONCE EVERY YEAR OR WHEN THE LOW BATTERY ICON APPEARS pages 2 8 USE AA SIZE ALKALINE BATTERIES USE AA SIZE ALKALINE BATTERIES POSITION BATTERIES AS SHOWN FAN W HEA...

Страница 11: ...Heat W1 W or H Heating W G or F Fan G O Rev Valve Energize to Cool O A label is provided on the backplate that prevents drafts originating inside the wall from entering the thermostat These drafts lef...

Страница 12: ...G R Y W Y B O G R 4 Wire 1 Stage Cooling 1 Stage Gas Heat Residential Gas or Electric Heat Electric Cool split systems package units Page 11 GAS OR ELECTRIC HEAT 4 Conductor 18 to 22 gauge unshielded...

Страница 13: ...Residential Heat Pumps split systems package units with no auxiliary heat FAN POWER G R COMPRESSOR Y W Y B O G R REVERSING VALVE O For Heat Pump or Electric Heat applications see page 17 or 18 for Ju...

Страница 14: ...Residential Heat Pumps split systems package units with no auxiliary heat FAN POWER G R COMPRESSOR Y W Y B O G R REVERSING VALVE B For Heat Pump or Electric Heat applications see page 17 or 18 for Ju...

Страница 15: ...rams FAN POWER G R W W Y B O G R 3 Wire 1 Stage Heat Residential Gas or Electric Heat units with a separately controlled fan GAS OR ELECTRIC HEAT 3 Conductor 18 to 22 gauge unshielded cable from the t...

Страница 16: ...Sample Wiring Diagrams POWER W R W Y B O G R 2 Wire 1 Stage Gas Heat Residential Gas or Millivolt units GAS OR ELECTRIC HEAT 2 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equ...

Страница 17: ...age 16 Sample Wiring Diagrams FAN COOLING POWER G R Y W Y B O G R 3 Wire 1 Stage Cooling Residential Electric Cool units 3 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipmen...

Страница 18: ...and Jumper are shown in the factory default positions for typical gas furnace heating with electric cooling Outputs active For normal operation do not connect to equipment OUTPUTS No Demand With Dema...

Страница 19: ...1 J2 Jumper is used to select Fan On G with Heat W Jumper shown in the factory default position Outputs active For normal operation do not connect to equipment OUTPUTS No Demand With Demand Cooling Mo...

Страница 20: ...hermostat Does Not Have Auxiliary Heat Emergency Heat Capability Leave jumpers in original factory default positions figure A for non heat pump applications Figure C OUTPUTS No Demand With Demand Cool...

Страница 21: ...thermostat Press the Up or Down buttons until the set temperature is 10 degrees below room temperature The HVAC unit should energize in the cooling mode pages 4 5 Turn on the power to the Heating Air...

Страница 22: ...ws holding the thermostat into the wall 72 Heat Off Cool FanOn FanAuto 72 Heat Off Cool FanOn FanAuto SYMPTOM The air conditioning does not attempt to turn on CAUSE The cooling setpoint is set too hig...

Страница 23: ...t TSTATBBNQ001 SYMPTOM The heating does not attempt to turn on CAUSE The heating setpoint is set too low or the Mode Switch is not set for Heat or the batteries are too weak REMEDY Consult the Normal...

Страница 24: ...ervicing unauthorized alteration or improper operation 3 Failure to start due to voltage conditions blown fuses open circuit breakers or other damages due to the inadequacy or interruption of electric...

Отзывы: