background image

PROGRAM button 
starts the 
programming 
process and moves 
you from one step to 
the next.

COPY PREVIOUS 
DAY button copies 
the previous day’s 
comfort schedule
into the current 
day’s schedule.

CHANGE DAY
button advances you 
to the next day to be 
programmed and 
advances the day 
of the week 
display.

ROOM TEMPERATURE
DISPLAY shows current 
room temperature.

TEMPERATURE SETTINGS
DISPLAY shows the 
temperature settings for
current time period.

OUTDOOR TEMPERATURE
DISPLAY shows the 
outdoor temperature.

TIME OF DAY 
DISPLAY exhibits the
time of day.

CLEAN FILTER 
INDICATOR lets you
know it is time to 
clean or replace your 
system’s air filter.

AUXILIARY HEAT 
INDICATOR is
displayed when a 
heat pump system’s 
auxiliary heat is on.

HUMIDITY
button changes
the display to
show himidity
readings and
allows you to
change humidity
settings.

VACATION button
changes temperature
and humidity set
points to lower levels
for optimum energy
efficiency while 
you’re away.

RESET FILTER
FUNCTION restarts
the timer that 
determines the next 
air filter change or 
cleaning. Ac
tivated by pressing
VACATION and
END buttons
simultaneously.

UP AND DOWN 
buttons change the
temperature and
humidity set points.
They are also used to
access outdoor 
temperature and 
indoor humidity 
levels.

FAN button chooses ON 
or AUTO fan operation.

HOLD/END button 
maintains the current
temperature settings.
Also used to end 
temperature and 
humidity programming
sequence.

SET TIME/TEMP button
allows you to enter 
the time of day and
temperature settings.

Year-Round Comfort.

Bryant’s Thermidistat

TM

Control provides enhanced, year-round comfort. By providing both

temperature and humidity control, this simple, yet powerful, device lets you take the steam out
of summer, the static out of winter and helps eliminate that annoying moisture build-up on
your windows when it’s cold outside. It’s never been quite this easy, and you’ve never had quite
this much comfort available through one control. 

Simple, Convenient Control.

Bryant puts your family’s comfort at your fingertips with simple instructions, responsive

push buttons and an easy-to-read, lighted display. Once set, the thermidistat control accurately
monitors indoor conditions and reliably meets your desired comfort levels. Plus, you have the 
convenience of temporarily bypassing your settings without disrupting your permanent
comfort schedule.

NOTE: Not all messages displayed in above illustration will appear at once in any situation.

MODE button selects OFF, HEAT,
COOL or AUTO operation. 
EMERGENCY HEAT (EHEAT) mode
is also included when the 
thermidistat control is installed
with a heat pump. 

Содержание Programmable Thermidistat

Страница 1: ...ontrol you have made a commitment to enjoying enhanced home comfort This Thermidistat Control provides reliable and consistent indoor temperatures with the added comfort of proper humidification Combi...

Страница 2: ...istat Control provides reliable and consistent indoor temperatures with the added comfort of proper humidification Combining the brains of a computer and the simplicity of a garage door opener in an a...

Страница 3: ...to access outdoor temperature and indoor humidity levels FAN button chooses ON or AUTO fan operation HOLD END button maintains the current temperature settings Also used to end temperature and humidit...

Страница 4: ...schedule 16 Overriding your comfort schedule 16 Checking the outdoor temperature and indoor humidity 17 Checking current programmed time and temperature settings 18 Checking current humidification and...

Страница 5: ...ontrol then follows the program schedule for that day Setting the current time 1 Press the SET TIME TEMP button The word TIME flashes on the display 2 Press the UP or DOWN buttons until the correct ti...

Страница 6: ...fter 15 seconds NOTE If you live in a Daylight Savings Time area you may advance the time 1 hour in the Spring by simultaneously pressing the SET TIME TEMP button and the UP button In the Fall you may...

Страница 7: ...HEAT NOTE In AUTO mode your system will heat OR cool as needed to reach your temperature settings 3 Continue to press the MODE button until you reach the desired setting Setting the fan operation 1 Pr...

Страница 8: ...is above the dehumidify setting the fan will shut off for 5 minutes after the air conditioner shuts off During this period a triangle next to the word ON will flash When the AUTO mode is selected the...

Страница 9: ...of the week is divided into 4 time periods WAKE DAY EVENING and SLEEP For each time period enter a start time heating temperature and cooling temperature in the appropriate blank Once completed this c...

Страница 10: ...stallation area of the country and your heating cooling equipment VACATION SCHEDULE Setting your comfort schedule Before you begin programming refer to page 5 of this manual to plan your personal comf...

Страница 11: ...time period and current day You may wish to begin pro gramming on a different day or time period To change the time period press the PROGRAM button as needed until the correct time period WAKE DAY EVE...

Страница 12: ...edule 5 Press the SET TIME TEMP button to select the cooling temperature setting for this time period The word COOL flashes on the display 6 Press the UP and DOWN buttons to adjust the cooling tempera...

Страница 13: ...schedule onto the remaining days of the week See the section on Copying a daily schedule for details NOTE During programming if you have not touched a button or made an entry within 3 min utes the pr...

Страница 14: ...with Monday so the following 4 days can be copied 2 Press the CHANGE DAY button to move to the next day 3 Press the COPY PREVIOUS DAY button The previous day s schedule will be entered into the new da...

Страница 15: ...DITY button 2 With the humidify hu setting displayed press the UP or DOWN button to adjust the humidify setting Humidity levels can be set from 10 to 45 Or to turn humidification off press the MODE bu...

Страница 16: ...conserve water and electricity with adequate humidification b AUTO indicator displayed humidify setting automatically changes according to outdoor weather This reduces the chance of moisture buildup...

Страница 17: ...is for use with variable capacity equipment only 1 Press the HUMIDITY button to enter the humidification programming mode The current indoor humidity large number is displayed along with the humidify...

Страница 18: ...the display See suggested settings on page 6 3 Press the HOLD END button to exit Setting the cool to dehumidify function This setting allows a standard comfort system to provide moderate dehumidificat...

Страница 19: ...Press the UP or DOWN buttons to raise or lower the dehumidify setting Dehumidification can be set from 50 to 90 To turn dehumidification off press the MODE button until OF appears on the display 3 Pre...

Страница 20: ...ming you desire Overriding your comfort schedule There are 2 ways to override the existing program 1 Pressing the HOLD END button By pressing the HOLD END button the Thermidistat Control will maintain...

Страница 21: ...temperature setting above the flashing indicator as needed To change the other setting for this time period press the SET TIME TEMP button until the other setting indicator flashes Pressing the UP or...

Страница 22: ...your Thermidistat Control does not include the outdoor air temperature sensor or the sensor is not working properly Check with your dealer if you are unsure Checking current programmed time and temper...

Страница 23: ...7 day schedule CAUTION Pressing any other buttons while reviewing current selections could alter the set program 6 Press the HOLD END button to exit the program mode Checking current temperature The T...

Страница 24: ...s the HUMIDITY button again to view the other setting 3 Press the HOLD END button Clean filter feature Your Thermidistat Control reminds you when it s time to change or clean your filter by displaying...

Страница 25: ...for you with vacation settings for temperature and humidity Heat 60 cool 85 hu 10 dhu 75 If these are okay skip ahead to vacation feature operation If you wish to enter new settings continue with this...

Страница 26: ...just the setting for the flashing mode 4 Press the SET TIME TEMP button until the other mode indicator flashes 5 Press the UP or DOWN button to adjust the setting for the flashing mode 6 Press the HUM...

Страница 27: ...ton to adjust the setting 8 Press the MODE button to select the vacation humidify or dehumidify mode 9 Press the HUMIDITY button to display the second setting either humidify or dehumidify 10 If you w...

Страница 28: ...rn dehumidification off OF In humidify you may enter a setting or turn humidification off OF Vacation feature operation 1 Press the VACATION button when you are ready to leave Be sure you have properl...

Страница 29: ...needed to maintain your temperature set points Auto changeover makes life easier because you no longer have to manually switch the thermostat between heating or cooling operation Just set your heating...

Страница 30: ...ndoor temperature During these transition periods you may notice that the actual temperature and your temperature setting don t match That s smart recovery in action adjusting temperatures in small in...

Страница 31: ...ATION and HOLD END buttons simultaneously after cleaning or replacing the filter to turn off the indicator and restart the timer NOTE This indicator does not reflect a problem with your system HOLD in...

Страница 32: ...uipment is operating the word COOL preceded by a small triangle is displayed below the cooling set point When the heating equipment is operating the word HEAT preceded by a small triangle is displayed...

Страница 33: ...ystem error message The display may appear as follows E3 E4 E5 or E6 indicates a problem with the indoor air sensor E3 indicates a problem with the outdoor air temperature sensor E4 E5 or E6 indicates...

Страница 34: ...warranty information please refer to the All Product Limited Warranty Card included in your information packet This Thermidistat Control is also eligible for manufacturer s extended system warranties...

Страница 35: ...ure Change Day Pg 1 Change day is a function of your Thermidistat Control s programming Once you ve programmed a day s heating or cooling schedule you move to the next day by pressing the CHANGE DAY b...

Страница 36: ...y pressing the COPY PREVIOUS DAY button Current Day and Time Pg 1 The day of the week and current time are displayed continuously on the display Dehumidification Level Pg 13 The amount of moisture to...

Страница 37: ...Hold Pg 2 This function allows you to override the programmed temperature settings Humidification Level Pg 10 The amount of moisture desired in your home to be supplied by the humidifier You can check...

Страница 38: ...u can override the system by pressing the HOLD END button to maintain the current temperature indefinitely or by pressing the UP and DOWN buttons to change the temperature settings for the remainder o...

Страница 39: ...o set the proper time ensuring accurate heating and cooling schedules Press the SET TIME TEMP button to activate Temperature Sensors Pg 12 Temperature sensors measure the current indoor or outdoor tem...

Страница 40: ...refers to the 4 time periods available including WAKE DAY EVE and SLEEP Time of day also refers to the time shown on the Thermidistat Control s display Up and Down Buttons Pg 1 These buttons are used...

Страница 41: ...NOTES 37...

Страница 42: ...NOTES 38...

Страница 43: ...NOTES 39...

Страница 44: ......

Отзывы: