Bryant Preferred 225B Скачать руководство пользователя страница 20

20

COMBINATION RATINGS CONTINUED

AHRI

Ref. No.

Model

Number

Coil Model Number

Furnace

Model Number

Cooling

Capacity

EER

SEER

High Temp

HSPF

Low Temp

E

Capacity

E COP

H

Capacity

H COP

3676732

225BNA036****A

CNPH*4221A**

355BAV042080

33,600

12.0

14.0

34,600

3.66

8.0

21,600

2.54

3676733

225BNA036****A

CNPH*4221A**

355BAV060080

33,600

12.0

14.0

34,400

3.66

8.0

21,600

2.54

3676734

225BNA036****A

CNPH*4221A**

355BAV060100

33,800

12.0

14.5

34,400

3.70

8.1

21,600

2.56

3676735

225BNA036****A

CNPH*4221A**

355BAV060120

33,800

12.0

14.5

34,200

3.68

8.1

21,400

2.56

3676704

225BNA036****A

CNPH*4221A**

359BAV036040

33,800

11.5

13.5

35,000

3.58

7.9

22,200

2.48

3676705

225BNA036****A

CNPH*4221A**

359BAV036060

33,800

11.5

14.0

35,000

3.64

8.0

22,000

2.52

3676706

225BNA036****A

CNPH*4221A**

359BAV060080

34,200

12.0

14.0

35,000

3.76

8.2

22,200

2.58

3676707

225BNA036****A

CNPH*4221A**

359BAV060100

34,200

12.2

14.5

34,800

3.74

8.2

21,800

2.58

3676741

225BNA036****A

CNPH*4221A**+TDR

33,800

11.0

13.0

35,600

3.62

8.0

22,800

2.48

3676743

225BNA036****A

CNPH*4321A**

359BAV036040

34,200

11.5

14.0

35,400

3.76

8.2

22,400

2.56

3676744

225BNA036****A

CNPH*4321A**

359BAV036060

34,200

12.0

14.5

35,400

3.86

8.4

22,400

2.60

3676745

225BNA036****A

CNPH*4321A**

359BAV060080

34,200

12.2

14.5

35,400

3.98

8.6

22,400

2.68

3676746

225BNA036****A

CNPH*4321A**

359BAV060100

34,200

12.5

15.0

35,200

3.96

8.6

22,200

2.68

3676932

225BNA036****A

CNPV*3617A**

313*AV048070

33,200

11.5

13.5

34,600

3.56

7.8

21,600

2.48

3676931

225BNA036****A

CNPV*3617A**

315(A,J)AV048090

33,400

12.0

14.0

34,200

3.60

7.9

21,400

2.52

3676934

225BNA036****A

CNPV*3617A**

353(A,B)AV036060

33,600

12.0

14.0

34,400

3.64

8.0

21,600

2.54

3676935

225BNA036****A

CNPV*3617A**

353(A,B)AV036080

33,400

12.0

14.0

34,400

3.62

8.0

21,400

2.52

3676936

225BNA036****A

CNPV*3617A**

353(A,B)AV048080

33,400

12.0

14.0

34,400

3.64

8.0

21,600

2.54

3676933

225BNA036****A

CNPV*3617A**

353AAV036040

33,400

12.0

14.0

34,400

3.64

8.0

21,400

2.54

3676930

225BNA036****A

CNPV*3617A**

355(A,C)AV042060

33,400

12.0

14.0

34,400

3.62

8.0

21,600

2.52

3676938

225BNA036****A

CNPV*3617A**

355BAV042060

33,400

12.0

14.0

34,400

3.62

8.0

21,600

2.52

3676940

225BNA036****A

CNPV*3617A**+TDR

33,600

11.0

13.0

35,600

3.56

7.9

22,600

2.46

3676950

225BNA036****A

CNPV*3621A**

313*AV048090

33,600

12.0

14.5

34,400

3.64

8.0

21,400

2.54

3676951

225BNA036****A

CNPV*3621A**

313*AV060110

33,600

12.0

14.5

34,400

3.68

8.1

21,400

2.56

3676949

225BNA036****A

CNPV*3621A**

315(A,J)AV060110

33,400

12.0

14.0

34,200

3.62

8.0

21,400

2.52

3676952

225BNA036****A

CNPV*3621A**

353(A,B)AV060100

33,400

12.0

14.5

34,200

3.62

8.0

21,200

2.54

3676946

225BNA036****A

CNPV*3621A**

355(A,C)AV042080

33,200

11.5

14.0

34,400

3.58

7.9

21,600

2.50

3676947

225BNA036****A

CNPV*3621A**

355(A,C)AV060080

33,200

12.0

14.0

34,200

3.58

7.9

21,400

2.50

3676948

225BNA036****A

CNPV*3621A**

355(A,C)AV060100

33,400

12.0

14.0

34,400

3.62

8.0

21,600

2.52

3676956

225BNA036****A

CNPV*3621A**

355BAV042080

33,200

11.5

14.0

34,400

3.58

7.9

21,600

2.50

3676957

225BNA036****A

CNPV*3621A**

355BAV060080

33,200

12.0

14.0

34,200

3.58

7.9

21,400

2.50

3676958

225BNA036****A

CNPV*3621A**

355BAV060100

33,400

12.0

14.0

34,400

3.62

8.0

21,600

2.52

3676960

225BNA036****A

CNPV*3621A**+TDR

33,600

11.0

13.0

35,600

3.56

7.9

22,600

2.46

3676970

225BNA036****A

CNPV*3717A**

313*AV048070

34,600

12.0

14.5

35,200

3.82

8.4

22,200

2.60

3676969

225BNA036****A

CNPV*3717A**

315(A,J)AV048090

34,600

12.5

15.0

34,800

3.86

8.4

21,600

2.64

3676972

225BNA036****A

CNPV*3717A**

353(A,B)AV036060

35,000

12.5

15.0

35,200

3.92

8.6

22,000

2.66

3676973

225BNA036****A

CNPV*3717A**

353(A,B)AV036080

34,800

12.5

15.0

35,000

3.90

8.5

21,800

2.66

3676974

225BNA036****A

CNPV*3717A**

353(A,B)AV048080

35,000

12.5

15.0

35,200

3.92

8.5

22,000

2.66

3676971

225BNA036****A

CNPV*3717A**

353AAV036040

35,000

12.5

15.0

35,000

3.92

8.5

22,000

2.66

3676968

225BNA036****A

CNPV*3717A**

355(A,C)AV042060

34,800

12.5

15.0

35,000

3.88

8.5

22,000

2.64

3676976

225BNA036****A

CNPV*3717A**

355BAV042060

34,800

12.5

15.0

35,000

3.88

8.5

22,000

2.64

3676978

225BNA036****A

CNPV*3717A**+TDR

35,000

11.5

13.5

36,000

3.78

8.3

23,000

2.56

3676981

225BNA036****A

CNPV*4217A**

313*AV048070

34,000

12.0

14.0

35,000

3.70

8.1

22,000

2.54

3676980

225BNA036****A

CNPV*4217A**

315(A,J)AV048090

34,000

12.0

14.5

34,600

3.74

8.2

21,600

2.58

3676983

225BNA036****A

CNPV*4217A**

353(A,B)AV036060

34,200

12.0

14.5

34,800

3.78

8.3

21,800

2.60

3676984

225BNA036****A

CNPV*4217A**

353(A,B)AV036080

34,200

12.0

14.5

34,800

3.76

8.3

21,800

2.60

3676985

225BNA036****A

CNPV*4217A**

353(A,B)AV048080

34,200

12.0

14.5

34,800

3.78

8.3

21,800

2.60

3676982

225BNA036****A

CNPV*4217A**

353AAV036040

34,200

12.0

14.5

34,800

3.78

8.3

21,800

2.60

3676979

225BNA036****A

CNPV*4217A**

355(A,C)AV042060

34,200

12.0

14.5

34,800

3.76

8.2

21,800

2.58

3676993

225BNA036****A

CNPV*4217A**

355BAV042060

34,200

12.0

14.5

34,800

3.76

8.2

21,800

2.58

3676995

225BNA036****A

CNPV*4217A**+TDR

34,000

11.0

13.0

35,800

3.68

8.1

22,800

2.50

3677001

225BNA036****A

CNPV*4221A**

313*AV048090

34,000

12.0

14.5

34,600

3.74

8.2

21,600

2.58

3677002

225BNA036****A

CNPV*4221A**

313*AV060110

34,000

12.0

14.5

34,600

3.76

8.3

21,600

2.60

3677000

225BNA036****A

CNPV*4221A**

315(A,J)AV060110

33,800

12.0

14.5

34,400

3.70

8.1

21,600

2.56

3677003

225BNA036****A

CNPV*4221A**

353(A,B)AV060100

33,800

12.0

14.5

34,400

3.72

8.2

21,400

2.58

3676997

225BNA036****A

CNPV*4221A**

355(A,C)AV042080

33,600

12.0

14.0

34,600

3.66

8.0

21,600

2.54

3676998

225BNA036****A

CNPV*4221A**

355(A,C)AV060080

33,600

12.0

14.0

34,400

3.66

8.0

21,600

2.54

3676999

225BNA036****A

CNPV*4221A**

355(A,C)AV060100

33,800

12.0

14.5

34,400

3.70

8.1

21,600

2.56

3677011

225BNA036****A

CNPV*4221A**

355BAV042080

33,600

12.0

14.0

34,600

3.66

8.0

21,600

2.54

3677012

225BNA036****A

CNPV*4221A**

355BAV060080

33,600

12.0

14.0

34,400

3.66

8.0

21,600

2.54

3677013

225BNA036****A

CNPV*4221A**

355BAV060100

33,800

12.0

14.5

34,400

3.70

8.1

21,600

2.56

3677017

225BNA036****A

CNPV*4221A**+TDR

33,800

11.0

13.0

35,600

3.62

8.0

22,800

2.48

3677022

225BNA036****A

CNPV*4324A**

315(A,J)AV066135

34,800

12.5

15.0

34,600

3.92

8.5

21,600

2.68

3677023

225BNA036****A

CNPV*4324A**

315(A,J)AV066155

34,800

12.5

15.5

34,600

3.94

8.6

21,400

2.68

3677025

225BNA036****A

CNPV*4324A**

355(A,C)AV042080

35,000

12.5

15.0

35,000

3.86

8.5

21,800

2.64

3677026

225BNA036****A

CNPV*4324A**

355(A,C)AV060080

35,000

12.5

15.0

34,800

3.86

8.5

21,800

2.64

3677021

225BNA036****A

CNPV*4324A**

355(A,C)AV060120

34,800

12.5

15.0

34,800

3.90

8.5

21,600

2.66

3677020

225BNA036****A

CNPV*4324A**

355AAV042040

34,600

12.2

14.5

34,800

3.84

8.4

21,800

2.62

3677041

225BNA036****A

CNPV*4324A**

355BAV042080

35,000

12.5

15.0

35,000

3.86

8.5

21,800

2.64

3677042

225BNA036****A

CNPV*4324A**

355BAV060080

35,000

12.5

15.0

34,800

3.86

8.5

21,800

2.64

3677040

225BNA036****A

CNPV*4324A**

355BAV060120

34,800

12.5

15.0

34,800

3.90

8.5

21,600

2.66

3677024

225BNA036****A

CNPV*4324A**

359BAV060100

(DNFLWONLY)

35,400

12.5

15.0

35,400

3.98

8.7

22,200

2.68

3677019

225BNA036****A

CNPV*4324A**

35,000

11.5

13.5

36,000

3.78

8.3

23,000

2.56

3677046

225BNA036****A

CNPV*4821A**

355(A,C)AV042080

34,200

12.0

14.5

34,800

3.78

8.3

21,800

2.60

3677060

225BNA036****A

CNPV*4821A**

355BAV042080

34,200

12.0

14.5

34,800

3.78

8.3

21,800

2.60

3677085

225BNA036****A

CNPV*6024A**

355(A,C)AV042080

34,600

12.0

14.5

34,800

3.84

8.4

21,800

2.62

3677097

225BNA036****A

CNPV*6024A**

355BAV042080

34,600

12.0

14.5

34,800

3.84

8.4

21,800

2.62

See notes on pg. 28

225B

Содержание Preferred 225B

Страница 1: ...ratings information INDUSTRY LEADING FEATURES BENEFITS Efficiency S 15 3 SEER 11 0 13 0 EER 7 7 9 0 HSPF Nominal S Microtube Technologyt refrigeration system S Indoor air quality accessories availabl...

Страница 2: ...t charging and air flow instructions Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life Use of the AHRI Certified TM Mark indicates a manufacturer s...

Страница 3: ...gerant VAPOR LINE SIZING AND COOLING CAPACITY LOSSES PURONR REFRIGERANT 1 STAGE HEAT PUMP APPLICATIONS Unit Nominal Size Btuh Maximum Liquid Line Diameters In OD Vapor Line Diameters In OD Cooling Cap...

Страница 4: ...50 250 250 250 250 24000 HP with Puron 3 8 250 250 250 250 250 250 250 30000 HP with Puron 3 8 250 250 250 250 250 250 250 36000 HP with Puron 3 8 250 250 250 250 250 250 250 42000 HP with Puron 3 8 2...

Страница 5: ...A Programmable Thermidistat T6 NRH01 A Non programmable Thermidistat T6 PHP01 Preferred Series Programmable HP Stat T6 NHP01 Preferred Series Non programmable HP Stat T2 PHP01 Legacy Series Programmab...

Страница 6: ...compressor lubrication on restart and minimizes the chance of liquid slugging Usage Guideline Required in low ambient cooling applications Required in long line applications Suggested in all commerci...

Страница 7: ...here electric heater is capable of three stage operation 13 Snow Stand Coated wire rack which supports unit 18 in 457 2 mm above mounting pad to allow for drainage from unit base Usage Guideline Sugge...

Страница 8: ...licable tables of the NEC ANSI NFPA 70 Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2 Time Delay fuse FLA Full Load Amps LRA Locked R...

Страница 9: ...3 4 16 3 4 17 215 257 36 1 8 X 39 1 4 X 39 3 8 225B042 A X O O O 35 28 15 16 3 7 8 7 8 6 9 16 28 7 16 9 1 8 2 15 16 5 8 17 16 3 4 14 3 4 245 290 36 1 8 X 39 1 4 X 32 9 16 225B048 A X O O O 35 28 15 16...

Страница 10: ...821 2 95 6 19 1 166 1 722 8 231 3 70 9 12 8 412 8 406 4 393 7 88 9 109 8 917 7 X 997 7 X 913 2 225B036 A X O O O 889 0 907 5 95 6 19 1 166 1 722 8 231 3 70 9 12 8 400 1 425 5 431 8 97 5 116 6 917 7 X...

Страница 11: ...ED HEATING CAPACITY MBTUH 225BNA018 FX4DNF019 225BNA024 FX4DNF025 225BNA042 FX4DNF043 225BNA030 FX4DNF031 225BNA060 FX4DNF061 225BNA048 FX4DNF049 225BNA036 FX4DNF037 10 23 0 17 78 10 12 22 20 6 67 30...

Страница 12: ...rvice 24 609 6 Service 24 609 6 Service 24 609 6 24 609 6 24 609 6 12 304 8 12 304 8 12 304 8 12 304 8 6 152 4 Note Numbers in mm IMPORTANT When installing multiple units in an alcove roof well or par...

Страница 13: ...000 12 2 14 5 18 000 3 94 8 4 10 900 2 56 3676575 225BNA018 A CNPH 2417A TDR 17 400 11 2 13 5 18 000 3 64 7 8 11 200 2 40 3676858 225BNA018 A CNPV 1814A 313 AV024045 17 400 12 0 14 5 17 400 3 72 7 9...

Страница 14: ...060 23 400 12 5 15 0 24 000 3 98 8 7 14 600 2 70 3676565 225BNA024 A CNPH 2417A 353 A B AV036080 23 400 12 5 15 0 24 000 3 94 8 7 14 600 2 68 3676563 225BNA024 A CNPH 2417A 353AAV036040 23 400 12 5 15...

Страница 15: ...4 600 2 70 3677131 225BNA024 A CSPH 2412A 355 A C AV042060 23 400 12 5 15 0 24 000 3 94 8 6 14 700 2 70 3677132 225BNA024 A CSPH 2412A 355 A C AV042080 23 400 12 5 15 0 24 000 3 82 8 5 14 500 2 64 367...

Страница 16: ...00 3 86 8 2 17 100 2 60 3676395 225BNA030 A CAP 3619A TDR 27 800 11 2 13 0 29 200 3 74 8 0 17 600 2 50 3676401 225BNA030 A CAP 3621A 313 AV048090 28 000 12 5 15 0 28 400 3 94 8 4 16 900 2 66 3676400 2...

Страница 17: ...80 28 800 12 5 15 5 28 600 4 08 8 6 16 900 2 70 3676918 225BNA030 A CNPV 3117A 353 A B AV048080 29 000 12 5 15 0 28 800 4 14 8 7 17 100 2 70 3676915 225BNA030 A CNPV 3117A 353AAV036040 28 800 12 5 15...

Страница 18: ...30 A CSPH 3612A 355BAV060080 27 800 12 5 15 0 28 000 3 94 8 3 16 800 2 64 3677250 225BNA030 A CSPH 3612A 355BAV060100 27 800 12 5 15 0 28 200 3 88 8 2 16 700 2 62 3677251 225BNA030 A CSPH 3612A 355BAV...

Страница 19: ...21 600 2 54 3676665 225BNA036 A CNPH 3617A 353 A B AV036080 33 400 12 0 14 0 34 400 3 62 8 0 21 400 2 52 3676666 225BNA036 A CNPH 3617A 353 A B AV048080 33 400 12 0 14 0 34 400 3 64 8 0 21 600 2 54 36...

Страница 20: ...5 15 0 35 000 3 90 8 5 21 800 2 66 3676974 225BNA036 A CNPV 3717A 353 A B AV048080 35 000 12 5 15 0 35 200 3 92 8 5 22 000 2 66 3676971 225BNA036 A CNPV 3717A 353AAV036040 35 000 12 5 15 0 35 000 3 92...

Страница 21: ...3677267 225BNA036 A CSPH 4212A 315 A J AV060110 34 000 12 0 14 5 34 600 3 80 8 2 21 600 2 62 3677268 225BNA036 A CSPH 4212A 315 A J AV066135 34 000 12 0 14 5 34 600 3 80 8 2 21 600 2 62 3677269 225BNA...

Страница 22: ...42 000 3 80 8 4 26 800 2 58 3676489 225BNA042 A CAP 4823A TDR 41 500 11 5 13 5 42 000 3 74 8 2 27 400 2 52 3676495 225BNA042 A CAP 4824A 313 AV060135 41 500 12 5 15 0 42 000 3 82 8 5 26 400 2 62 3676...

Страница 23: ...A 355BAV042060 41 500 12 0 14 5 42 000 3 72 8 2 26 600 2 54 3676996 225BNA042 A CNPV 4217A TDR 41 500 11 5 13 5 42 000 3 68 8 1 27 400 2 50 3677008 225BNA042 A CNPV 4221A 313 AV048090 41 000 12 0 14 5...

Страница 24: ...A CSPH 4212A 359BAV060100 41 000 12 0 14 0 42 000 3 80 8 2 26 400 2 60 3677317 225BNA042 A CSPH 4212A TDR 41 000 11 5 13 5 42 000 3 74 8 0 27 400 2 54 3677329 225BNA042 A CSPH 4812A 313 AV048070 41 50...

Страница 25: ...3676528 225BNA048 A CAP 6024A 355BAV060120 46 000 12 0 14 5 45 500 3 72 8 5 27 800 2 60 3676529 225BNA048 A CAP 6024A TDR 46 500 11 5 13 5 46 500 3 74 8 3 28 800 2 58 3676531 225BNA048 A CAP 6025A 359...

Страница 26: ...048 A CNPV 4824A 359BAV060100 DNFLWONLY 46 000 12 0 14 0 46 000 3 68 8 3 27 800 2 58 3677084 225BNA048 A CNPV 4824A TDR 45 500 11 5 13 5 46 500 3 68 8 3 28 600 2 54 3677089 225BNA048 A CNPV 6024A 313...

Страница 27: ...56 500 3 68 8 1 36 200 2 58 3676815 225BNA060 A CNPH 6024A 313 AV060110 55 500 12 0 14 0 56 500 3 70 8 2 35 600 2 62 3676816 225BNA060 A CNPH 6024A 313 AV060135 55 500 12 0 14 0 56 500 3 68 8 1 35 60...

Страница 28: ...14 0 56 500 3 68 8 1 36 000 2 58 3677390 225BNA060 A CSPH 6012A 359BAV060080 56 000 11 5 13 0 58 000 3 66 8 0 37 000 2 56 3677391 225BNA060 A CSPH 6012A 359BAV060100 55 500 11 5 13 5 58 000 3 68 8 1 3...

Страница 29: ...18 29 18 29 1 12 17 54 17 54 1 27 16 74 16 74 1 43 15 88 15 88 1 61 14 96 14 96 1 81 13 98 13 98 2 04 COOLING INDOOR MODEL CAPACITY POWER FURNACE MODEL FX4DNF019 1 00 1 00 FB4CNF018 0 99 1 00 FB4CNF0...

Страница 30: ...09 CNPV 3014A 0 98 1 09 CNPV 3017A 0 98 1 09 CNPV 3117A 0 98 1 06 CSPH 2412A 0 98 1 09 CSPH 3012A 0 98 1 09 CAP 2414A 0 98 0 98 315 A J AV036070 CAP 3014A 0 98 0 98 315 A J AV036070 COOLING INDOOR MOD...

Страница 31: ...355 A C AV060100 CNPH 3017A 0 98 0 98 355 A C AV060100 CSPH 2412A 0 98 0 98 355 A C AV060100 CSPH 3012A 0 98 0 98 355 A C AV060100 CNPH 2417A 0 98 0 98 355 A C AV060120 CNPH 3017A 0 98 0 98 355 A C AV...

Страница 32: ...CAP 3621A 0 98 1 09 CNPF 3618A 0 98 1 09 CNPH 3017A 0 98 1 09 CNPH 3617A 0 98 1 09 CNPV 3014A 0 98 1 09 CNPV 3017A 0 98 1 09 CNPV 3117A 1 01 1 09 CNPV 3617A 0 98 1 09 CNPV 3621A 0 98 1 09 COOLING INDO...

Страница 33: ...42080 CSPH 3612A 0 98 0 98 355 A C AV042080 CAP 3621A 0 98 0 98 355 A C AV060080 CNPH 3017A 0 98 1 02 355 A C AV060080 CNPH 3617A 0 98 1 02 355 A C AV060080 CNPV 3621A 0 98 1 00 355 A C AV060080 CSPH...

Страница 34: ...97 1 10 CAP 3621A 0 97 1 10 CAP 4221A 0 97 1 10 CAP 4224A 0 97 1 10 CNPF 3618A 0 97 1 10 CNPH 3617A 0 97 1 10 CNPH 4221A 0 97 1 10 CNPV 3617A 0 97 1 10 CNPV 3621A 0 97 1 10 CNPV 3717A 1 01 1 09 CNPV...

Страница 35: ...80 CAP 4221A 0 97 1 01 355 A C AV060080 CNPH 3617A 0 95 1 04 355 A C AV060080 CNPH 4221A 0 97 1 01 355 A C AV060080 CNPV 3621A 0 95 0 99 355 A C AV060080 CNPV 4221A 0 97 1 01 355 A C AV060080 CNPV 432...

Страница 36: ...4217A 1 00 1 09 CNPV 4221A 0 99 1 07 CNPV 4324A 1 01 1 05 CNPV 4821A 1 00 1 09 CNPV 4824A 1 00 1 09 CSPH 4212A 0 99 1 07 CSPH 4812A 1 00 1 09 CAP 4817A 1 01 1 01 353 A B AV036080 CNPH 4221A 0 99 1 03...

Страница 37: ...NPV 4821A 0 99 1 03 355 A C AV042080 CSPH 4212A 0 99 1 03 355 A C AV042080 CSPH 4812A 0 99 1 03 355 A C AV042080 CAP 4221A 0 98 1 02 355 A C AV060080 CAP 4821A 1 00 1 04 355 A C AV060080 CNPH 4221A 0...

Страница 38: ...08 CSPH 4812A 0 96 1 04 CSPH 6012A 0 98 1 06 CAP 4817A 0 96 1 04 315 A J AV048090 CNPH 4821A 0 95 0 99 315 A J AV048090 CNPH 6024A 0 97 1 01 315 A J AV048090 CNPH 6124A 0 97 1 01 315 A J AV048090 COO...

Страница 39: ...96 1 00 355 A C AV060120 CNPV 6024A 0 97 1 01 355 A C AV060120 CNPV 6124A 0 98 0 98 355 A C AV060120 CNPV 6124A 0 99 1 01 355 A C AV060120 CSPH 4812A 0 96 1 00 355 A C AV060120 CSPH 6012A 0 98 1 02 3...

Страница 40: ...6024A 0 97 1 06 CNPH 6124A 0 98 1 07 CNPV 6024A 0 97 1 06 CNPV 6124A 0 99 1 08 CSPH 6012A 0 97 1 06 CAP 6021A 0 97 1 06 315 A J AV060110 CNPH 6024A 0 97 1 06 315 A J AV060110 CNPH 6124A 0 98 1 07 315...

Страница 41: ...NF018 1 01 1 05 FB4CNF024 1 01 1 05 FE4ANF002 1 00 1 02 FF1ENP018 1 03 1 15 FF1ENP019 1 01 1 05 FF1ENP024 1 03 1 13 FF1ENP025 1 01 1 02 FV4BNF002 1 00 1 02 FV4CNF002 1 00 1 02 FX4CNF018 1 01 1 05 FX4C...

Страница 42: ...045 CNPH 2417A 1 00 1 02 313 AV024045 CNPH 3017A 1 00 1 01 313 AV024045 CNPV 2414A 1 00 1 02 313 AV024045 CNPV 3014A 1 00 1 03 313 AV024045 CSPH 2412A 1 00 1 02 313 AV024045 CSPH 3012A 1 00 1 02 313 A...

Страница 43: ...TY POWER FURNACE MODEL CSPH 2412A 1 00 1 03 359BAV036040 CSPH 3012A 1 00 1 02 359BAV036040 CAP 3619A 1 00 0 99 359BAV036060 CNPH 2417A 1 00 1 01 359BAV036060 CNPH 3017A 1 00 1 00 359BAV036060 CNPH 311...

Страница 44: ...1 01 315 A J AV036070 CAP 3017A 0 99 1 02 315 A J AV048090 CAP 3617A 0 99 1 02 315 A J AV048090 CNPH 3017A 0 99 1 02 315 A J AV048090 CNPH 3617A 0 99 1 02 315 A J AV048090 CNPV 3017A 0 99 1 02 315 A...

Страница 45: ...0 99 1 04 355 A C AV060100 CNPV 3621A 0 99 1 04 355 A C AV060100 CSPH 3012A 0 99 1 04 355 A C AV060100 CSPH 3612A 0 99 1 02 355 A C AV060100 CNPH 3017A 0 99 1 02 355 A C AV060120 CNPH 3617A 0 99 1 02...

Страница 46: ...97 1 04 315 A J AV048090 CNPH 3617A 0 97 1 05 315 A J AV048090 CNPH 4221A 0 98 1 03 315 A J AV048090 CNPV 3617A 0 97 1 05 315 A J AV048090 CNPV 3717A 0 99 0 99 315 A J AV048090 CNPV 4217A 0 98 1 02 3...

Страница 47: ...05 355 A C AV060100 CNPH 4221A 0 98 1 03 355 A C AV060100 CNPV 3621A 0 98 1 05 355 A C AV060100 CNPV 4221A 0 98 1 03 355 A C AV060100 CSPH 3612A 0 99 1 02 355 A C AV060100 CSPH 4212A 0 99 1 01 355 A...

Страница 48: ...4221A 1 01 1 05 315 A J AV060110 CAP 4821A 1 01 1 02 315 A J AV060110 CNPH 4221A 1 01 1 05 315 A J AV060110 CNPH 4821A 1 01 1 02 315 A J AV060110 CNPV 4221A 1 01 1 05 315 A J AV060110 CNPV 4324A 1 01...

Страница 49: ...1 02 355 A C AV060120 CSPH 4212A 1 00 1 01 355 A C AV060120 CSPH 4812A 1 01 1 01 355 A C AV060120 CAP 4224A 1 01 1 07 355AAV042040 CAP 4824A 1 01 1 04 355AAV042040 CNPH 4221A 1 01 1 07 355AAV042040 C...

Страница 50: ...V 6124A 0 99 1 00 315 A J AV060110 CSPH 4812A 0 98 1 02 315 A J AV060110 CSPH 6012A 0 98 1 00 315 A J AV060110 CAP 4824A 0 97 1 00 315 A J AV066135 CAP 6024A 0 97 0 99 315 A J AV066135 CNPH 4821A 0 97...

Страница 51: ...01 313 AV048090 CSPH 4812A 0 98 1 01 313 AV048090 CSPH 6012A 0 98 0 99 313 AV048090 CAP 4821A 0 97 1 01 313 AV060110 CAP 6021A 0 97 0 99 313 AV060110 CNPH 4821A 0 97 1 00 313 AV060110 CNPH 6024A 0 97...

Страница 52: ...A 0 99 1 04 315 A J AV060110 CNPH 6024A 0 99 1 04 315 A J AV060110 CNPH 6124A 0 99 1 03 315 A J AV060110 CSPH 6012A 0 99 1 03 315 A J AV060110 CAP 6024A 0 99 1 03 315 A J AV066135 CNPH 6024A 0 99 1 03...

Страница 53: ...ard Condenser fan motors will be totally enclosed 1 phase type with class B insulation and permanently lubricated bearings Shafts will be corrosion resistant Fan blades will be statically and dynamica...

Страница 54: ...ft 6 1 m consult Residential Piping and Longline Guideline and Service Manual available from equipment distributor 8 If any refrigerant tubing is buried provide a 6 in 152 4 mm vertical rise to the va...

Отзывы: