Step 4

Wiring

a. Ensure power has been removed from the heating and

cooling system.

b. Turn the Perfect Air

t

Air Purifier power switch off.

c. Connect the power cord and the flow sensor cord to the

power supply connector and the flow sensor connector

(see Fig. 7 and Fig. 8).

NOTE

: The power cord can be routed through the opposite side

of the cabinet. Zip ties have been enclosed to secure the power
cord to the side of the power supply.

NOTE

: Cable connector and block--off plates will need to be

removed and re--installed if the power cord is re--routed. Screws
on the cable connector clamp should be tightened to 9 in. -- lbs.
torque.

NOTE

: The Perfect Air

t

Air Purifier is to be powered by

208/230Vac/60 Hz.

NOTE

: The Perfect Air

t

Air Purifier should only be powered

when airflow is present. An airflow sensor is factory--installed
(See Fig. 2 and Fig. 11). In order to bypass the airflow sensor,
use the special bypass jumper included in the parts bag. With the
bypass jumper in place, the air purifier will be on at all times
when connected to electrical line power (see Fig. 10).

d. Attach the quick connect terminals to the fused power

connector leads (in parts bag attached to power cord) and

connect to incoming field power. Attach the ground ring

to fan coil chassis ground. (See Fig. 10.)

ELECTRICAL

SHOCK

AND

HIGH

VOLTAGE

HAZARD

Failure to follow this warning could result in personal injury

or death.
Before installing or servicing system, always turn off main

power to system. There may be more than 1 disconnect

switch.

!

WARNING

EQUIPMENT DAMAGE HAZARD

Failure to follow this caution may result in equipment

damage or improper operation.
This unit cannot be powered directly from blower motor

leads. Do not wire directly to blower motor. Wiring to

blower motor will damage power supply and void

warranty.

CAUTION

!

A06414

Fig. 7

---

Flow Sensor Cable Installed

A06413

Fig. 8

---

Power Cord Installed

AIR FLOW SENSOR CABLE OR AIR FLOW

SENSOR BYPASS PLUG MUST BE CONNECTED

TO THE POWER SUPPLY IN ORDER TO

ACTIVATE THE AIR PURIFIER

NOTICE

A06670

Fig. 9

---

Airflow Sensor Bypass Plug Installed

GAP

A

B

Содержание PERFECT AIR 1620

Страница 1: ...CSA certified for shock and electrical fire hazard only La Perfect Airt Air Purifier certification CSA vise uniquement les risques de choc electrique et A06367 Fig 1 GAPAB Unit SAFETY CONSIDERATIONS I...

Страница 2: ...recommended and a standard disposable furnace filter should be mounted between the humidifier and the air purifier to trap hard water salt deposits and water droplets Transitions If the return air du...

Страница 3: ...Purifier or door can be rotated 180_ to accommodate the cabinet orientation c The location of the Perfect Airt Air Purifier should be readily accessible Enough room should be provided for periodic rep...

Страница 4: ...work See Fig 6 h Seal seams with tape or caulking after the Perfect Airt Air Purifier cabinet has been secured ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Failure to follow this warning could result in...

Страница 5: ...bag With the bypass jumper in place the air purifier will be on at all times when connected to electrical line power see Fig 10 d Attach the quick connect terminals to the fused power connector leads...

Страница 6: ...OWER CONNECTION TO L2 FIELD POWER SUPPLY TO L1 FIELD POWER SUPPLY 5 AMP IN LINE FUSES GROUND ATTACH TO FAN COIL GROUND CHASSIS CABLE CONNECTOR TO SECURE POWER CORD TO FAN COIL CABINET A06515 Fig 10 Fa...

Страница 7: ...her the TrueSenset dirty filter algorithm or time The installer should use their discretion to select the most appropriate option based on the initial system static pressure Step 3 Maximizing Performa...

Страница 8: ...iate protective clothing and gloves when handling parts WARNING Step 6 Slide out the Safety Screen and set aside NOTE Best cleaning tools 5 inch handle paint brush with 2 inch width or greater brush p...

Страница 9: ...position Step 3 Confirm that the fan coil blower is operating Step 4 Confirm that 208 230 VAC power is provided Attach power supply connector to the air purifier when the fan coil blower is operating...

Страница 10: ...mum Airflow CFM 1350 1800 2000 Efficiency Equivalent to MERV 15 Equivalent to MERV 15 Equivalent to MERV 15 Replacement Cartridge GAPCBBAR1620 GAPCBBAR2020 GAPCBBAR2420 Initial Pressure Drop in w c at...

Страница 11: ...ough a registered servicing dealer for credit 4 All work shall be performed during normal working hours LIMITATIONS OF WARRANTIES ALL IMPLIED WARRANTIES AND OR CONDITIONS INCLUDING IMPLIED WARRANTIES...

Страница 12: ...change at any time specifications or designs without notice and without incurring obligations EBryant Heating Cooling Systems 7310 W Morris St Indianapolis IN 46231 Printed in U S A Edition Date 02 0...

Отзывы: