24
Table 1 – Outputs
Equip
Config
Tstat
Model
COOL
STG 1
COOL
STG 2
HEAT
STG 1
HEAT
STG 2
HEAT
STG 3
EM HEAT
SS AC
Opt 1 = AC
T2---PAC
T2---NAC
T2---PHP
T2---NHP
Y
--- ---
W
--- ---
--- ---
--- ---
SS HP
Opt 1 = HP
RVS = O
Opt 10 = C
T2---PHP
T2---NHP
Y,
O/B
--- ---
Y
Y,
W
--- ---
W
SS HP
Opt 1 = HP
RVS = B
Opt 10 = H
T2---PHP
T2---NHP
Y
--- ---
Y,
O/B
Y,
W,
O/B
--- ---
W
2SPD AC
Opt 1 = A2
T2---PHP
T2---NHP
Y1
Y1,
Y
W
--- ---
--- ---
--- ---
2SPD HP
Opt 1 = H2
RVS = O
Opt 10 = C
T2---PHP
T2---NHP
Y1,
O/B
Y1,
Y,
O/B
Y1
Y1,
Y
Y1,
Y,
W
W
2SPD HP
Opt 1 = H2
RVS = B
Opt 10 = H
T2---PHP
T2---NHP
Y1
Y1,
Y
Y1,
O/B
Y1,
Y,
O/B
Y1,
Y,
W,
O/B
W
Heat Only
Opt 1 = H
T2---PHP
T2---NHP
T2---P AC
T2---NAC
--- ---
--- ---
W
--- ---
--- ---
--- ---
Cool Only
Opt 1 = C
T2---PAC
T2---NAC
Y
--- ---
--- ---
--- ---
--- ---
--- ---
Cool Only
Opt 1 = C
T2---PHP
T2---NHP
Y1
Y1,Y
--- ---
--- ---
--- ---
--- ---