background image

288BNV EVOLUTION® V: Owner’s Manual

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

3

Notes:

1.

The above list may not include all maintenance items. Inspection intervals may vary depending on climate and operating hours. Consult your HVAC dealer about a service contract for seasonal inspections.

2.

Do not use harsh chemicals or high pressure water on coils. More frequent rinsing is required for units near a sea coast.

Maintenance Checklist

Recommended

Interval

*

*. Monthly maintenance items and outdoor unit rinsing may be performed by the consumer. All other maintenance items and all service work must be performed by a qualified service 

technician. Read all waring labels.

Outdoor unit specific:

Monthly

Annual

Clear away debris and vegetation near unit.

X

Inspect cabinet for damage. Replace components that are damaged or severely rusted.

X

Inspect electrical disconnect for proper function. Repair or replace as necessary.

X

Inspect electrical wiring and connections.  Tighten loose connections. Inspect and perform functional test of equipment as needed to ensure proper 

function. Repair or replace damaged or overheated components and wiring.

X

Check refrigerant system subcooling and/or superheat (system dependent).

X

Inspect inside of unit. Clean if debris is present.

X

Inspect condenser coil. Clean if dust, dirt, or debris is present.  Rinse unit with fresh water (see Note 2).

X

Inspect motor and fan for damage. Make sure fan spins freely.

X

Indoor specific:  (for fossil fuel furnaces and accessories, refer to unit specific literature)

Inspect, clean, or replace air filter if dirty.

X

Inspect and clean blower assembly (includes blower housing, wheel, and motor).

X

Inspect internal and external of cabinet. Clean as needed.

X

Inspect electrical disconnect for proper function. Repair or replace as necessary.

X

Inspect electrical components, wiring, and connections. Tighten loose connections. Repair or replace damaged components and wiring.

X

Inspect evaporator coil. Clean if dust, dirt, or debris is present (see Note 2).

X

Clean condensate pan, trap, and drain lines (more frequent maintenance may be required in humid climates - consult your local HVAC dealer).

X

Inspect airflow system (ductwork). Check for leaks and repair as needed.

X

Содержание EVOLUTION V 288BNV

Страница 1: ...s your heat pump will run for longer periods at a time than on moderate days Your system will also run for longer periods of time under the following conditions Frequent opening of exterior doors Operating laundry appliances Taking hot showers More than the usual number of people present in the home More than the normal number of electric lights in use Drapes or blinds are open on the sunny side o...

Страница 2: ...el it promptly to assure proper drainage If you notice water or ice collecting beneath the unit arrange for it to be drained away from the unit SEA COAST COIL MAINTENANCE Coastal locations often require additional maintenance of the outdoor unit due to highly corrosive airborne ocean salt Although your new Bryant system is made of galvanized metal and is protected by top grade paint take the addit...

Страница 3: ...ghten loose connections Inspect and perform functional test of equipment as needed to ensure proper function Repair or replace damaged or overheated components and wiring X Check refrigerant system subcooling and or superheat system dependent X Inspect inside of unit Clean if debris is present X Inspect condenser coil Clean if dust dirt or debris is present Rinse unit with fresh water see Note 2 X...

Страница 4: ...rris Street Indianapolis IN 46231 Catalog No OM288B 03 Edition Date 10 19 Replaces OM288B 02 288BNV EVOLUTION V Owner s Manual Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 4 ...

Отзывы: