NOTE

: Read the entire instruction manual before starting the

installation.

pointSET

t

U.S. Pat No. 7,415,102

TABLE OF CONTENTS

PAGE

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . . .

INSTALLATION CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . .

INTRODUCTION

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Computer Requirements

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAM INSTALLATION

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

BEFORE STARTING:

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Check Equipment and Job Site

2

. . . . . . . . . . . . . . . . . . . . . . . .

Component Location and Wiring Considerations

2

. . . . . . . . . .

Install Components

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Connect Evolution Systems

2

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Connect Auxiliary Sensor (optional)

3

. . . . . . . . . . . . . . . . . . . .

RS--232 Connector

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Ethernet Interface Module

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Connect Power Source

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Connect Network Cable

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

System Start--Up

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Network Setup

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

MAC Address and Serial Number

3

. . . . . . . . . . . . . . . . . . . . . .

Self--Test

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Updating System Profile

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Local PC Access

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Account Setup

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TROUBLESHOOTING

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,

or use can cause explosion, fire, electrical shock, or other
conditions which may cause death, personal injury or property

damage. Consult a qualified installer, service agency or your
distributor or branch for information or assistance. The qualified

installer or agency must use factory--authorized kits or accessories

when modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,
and work gloves. Have a fire extinguisher available. Read these

instructions thoroughly and follow all warnings and cautions
included in literature and attached to the unit. Consult local

building codes and the current edition of the National Electrical

Code (NEC) NFPA 70.

In Canada, refer to the current editions of the Canadian
Electrical Code CSA C22.1.

Recognize safety information. When you see this symbol

on

the unit and in instructions or manuals, be alert to the potential for

personal injury. Understand the signal words

DANGER

,

WARNING

, and

CAUTION

. These words are used with the

safety--alert symbol.

DANGER

identifies the most serious hazards,

which

will

result in severe personal injury or death.

WARNING

signifies hazards, which

could

result in personal injury or death.

CAUTION

is used to identify unsafe practices, which

may

result

in minor personal injury or product and property damage.

NOTE

is used to highlight suggestions which

will

result in enhanced

installation, reliability, or operation.

INSTALLATION CONSIDERATIONS

The CAT--5 Broadband Remote Access Module (CAT--5 B--SAM),

part number SYSTXBBRCT01, is powered with a field--supplied
24VAC transformer. A 120VAC supply must be near the mounting

location when using the accessory plug--in 24VAC transformer.

Provisions must be made to secure the accessory plug--in
transformer to the outlet.

The D--wire (24VAC) from the

Evolution

R

system must NOT be used to power the Remote

Access Module, and should not be connected to the SAM

module.

This instruction covers the physical installation and start up of the
CAT--5 B--SAM. Use this instruction to guide the actual

installation process after the Evolution system(s) have been
installed. One CAT--5 B--SAM is capable of handling two

Evolution systems.

INTRODUCTION

The CAT- 5 B- SAM is used differently for previous generation

Evolution systems using the UID/UIZ wall controls versus the

newer Evolution

R

Connex

t

systems.

For previous generation systems using the UID/UIZ wall

controls

, the SAM connects to a network router and allows remote

connectivity for up to two Evolution systems within the same

building. The Evolution system owner as well as authorized dealer
can monitor and control the system via the Internet. The CAT--5

B--SAM communicates through the homeowner’s cable or DSL

Internet service. Broadband Internet service with a network router
is required. The CAT--5 B--SAM is not compatible with dial--up

Internet service. The SAM also provides an interface to Home
Automation systems, utilizing either the RS-232 serial port

connection, or the web page function, available on the Local Area

Network (LAN) within the home or building.

Содержание Evolution SYSTXBBRCT01 Series

Страница 1: ...R WARNING and CAUTION These words are used with the safety alert symbol DANGER identifies the most serious hazards which will result in severe personal injury or death WARNING signifies hazards which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage NOTE is used to highlight suggestions whi...

Страница 2: ...nnect switch must be in the OFF position and install a lockout tag There may be more than one power disconnect switch Lock out and tag switch with a suitable warning label WARNING NOTE All wiring must comply with national state and local codes LOCATING THE UNIT CAT 5 B SAM is approved for indoor use only and should never be installed with any of its components exposed to outdoor environmental cond...

Страница 3: ...rk Cable Previous generation UID UIZ systems only Connect a network cable RJ45 terminated from the Local Area Network LAN See Fig 1 for cable attachment location System Start Up The Evolution system wall control will automatically find the CAT 5 B SAM at system power on during the system self installation sequence If the SAM is being added to an existing system initiate a full system re install se...

Страница 4: ...l happen automatically within one hour or can be manually forced with the process described above Local PC Access Previous generation UID UIZ systems only The Evolution system s can be monitored and the CAT 5 B SAM setup can be changed through use of the CAT 5 B SAM s embedded web server From a PC on the same network as the CAT 5 B SAM type the IP address of the CAT 5 B SAM in the address field of...

Страница 5: ... of the CAT 5 B SAM s network module SUBNET MASK If the IP TYPE is STATIC this can be changed to a different subnet number Use the Temp buttons to move between numbers and the Time button to choose numbers If IP TYPE is DHCP the SUBNET MASK cannot be changed DEFAULT GATEWAY If the IP TYPE is STATIC this can be changed to point to a different gateway Use the Temp buttons to move between numbers and...

Страница 6: ...ntinue or change at any time specifications or designs without notice and without incurring obligations E2013 Bryant Heating Cooling Systems D 7310 W Morris St D Indianapolis IN 46231 Edition Date 04 13 Replaces IIBBRCT 02 Catalog No IIBBRCT 03 ...

Отзывы: