37
•
Dehum Drain Time
: Adjustable from 5 to 60 minutes or OFF. Default
= 15 minutes
•
Electric Reheat
: Yes or No. Default = No
6.3.2.4. Fan Coil G-Terminal Input
This setup option selects desired operation when the
R
to
G
contact is
closed on the fan coil control board. Under this function option,
fan
turns
on fan to selected fan speed when G terminal is energized. Use the
alert
function to select the contact state for an alert. Select Normally Open or
Normally Closed, and then save your selection.
Shutdown
shuts off fan
and equipment when initiated. After the selections are made, touch
Save
.
•
Shutdown
:
– Normally Open
– Normally Closed
– The shutdown function may not be immediate. Blower off delays,
etc., will still be used. The shutdown is not intended for commercial
applications. If immediate shutdown is required, provision must be
made to remove power to indoor unit.
A13229
6.3.2.5. Fan Coil G-Terminal Alert
Use the
alert
function to select the contact state for an alert. Select
Normally Open
or
Normally Closed
, and then save your selection.