SAM SETUP 1

AUX:

AUX SENSOR

IP TYPE:

DHCP

IP:

192.168.100.0

MAC ADDR:

00:01:02:03:04:05

SUBNET MASK:

255.255.255.000

SERVER
STATUS:

CONNECTED

< BACK

NEXT >

SAM SETUP 2

DEFAULT GATEWAY:

192.168.001.001

DNS SERVER:

061.010.231.015

PORT:

49152

SERVER
STATUS:

CONNECTED

< BACK

NEXT >

AUX:

The auxiliary sensor can be renamed to something meaningful, such as WATER or GENERATOR. Use the Temp +/-- buttons to move

between letters, and the Time +/-- button to choose letters.

IP TYPE:

Choose DHCP (default) or STATIC for the Internet addressing type.

IP:

Shows the current IP address of the CAT--5 B--SAM. If IP TYPE is STATIC then this item can be changed. Use the Temp +/-- buttons to

move between letters, and the Time +/-- button to choose letters. If IP TYPE is DHCP, the IP address cannot change.

MAC ADDR:

Shows the MAC Address of the CAT--5 B--SAM’s network module.

SUBNET MASK:

If the IP TYPE is STATIC, this can be changed to a different subnet number. Use the Temp +/-- buttons to move between

letters, and the Time +/-- button to choose letters. If IP TYPE is DHCP, the SUBNET MASK cannot be changed.

DEFAULT GATEWAY:

If the IP TYPE is STATIC, this can be changed to point to a different gateway. Use the Temp +/-- buttons to move

between letters, and the Time +/-- button to choose letters. If IP TYPE is DHCP, the DEFAULT GATEWAY cannot be changed.

DNS SERVER:

If the IP TYPE is STATIC, this can be changed to point to a different DNS server. Use the Temp +/-- buttons to move

between letters, and the Time +/-- button to choose letters. If IP TYPE is DHCP, the DNS SERVER cannot be changed.

PORT:

This can be changed to use a different port through the homeowner’s network. The default is port 49152.

SERVER STATUS:

Shows status of the CAT--5 B--SAM connection to Bryant’s servers. If the screen shows NON CONNECTED, please

check network settings or network cable.

Home

Automation

Connection

(RS- 232)

STATUS

COMM1

COMM2

WLSC

WLS

A1

B1

C1

A2

B2

C2

SERIAL NUMBER

TEST

AUXILIARY

SENSOR

ABC TO

SYSTEM 1

ABC TO

SYSTEM 2

24VAC

Ethernet
Module

A06512

Fig. 1 -- CAT--5 Module Control Board

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

E

2012 Bryant Heating & Cooling Systems

D

7310 W. Morris St.

D

Indianapolis, IN 46231

Printed in U.S.A.

Edition Date: 02/12

Replaces: IIBBRCT--- 01

Catalog No. IIBBRCT---02

SYSTX

B

B

R

C

T01

Содержание EVOLUTION CAT-B-SAM

Страница 1: ...fety alert symbol DANGER identifies the most serious hazards which will result in severe personal injury or death WARNING signifies hazards which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage NOTE is used to highlight suggestions which will result in enhanced installation reliability or...

Страница 2: ...iring of the ABC connector will cause the system to operate improperly Check to make sure all wiring is correct before proceeding with installation or turning on of power CAUTION Connect Evolution Systems Connect the A B and C wires from the Evolution System to terminals labeled A1 B1 and C1 Connect the second Evolution System if present to the terminals labeled A2 B2 and C2 ABC bus wiring only re...

Страница 3: ...curs The system can be forced to send its information through the following process if Internet and telephone access is required immediately Press and hold the Radio Test button for 15 seconds When the button is first pressed the Red LED will turn on Five seconds into the press the Yellow LED will turn on Fifteen seconds into the press the Green COM1 LED will turn on Release the button when the Gr...

Страница 4: ...GATEWAY If the IP TYPE is STATIC this can be changed to point to a different gateway Use the Temp buttons to move between letters and the Time button to choose letters If IP TYPE is DHCP the DEFAULT GATEWAY cannot be changed DNS SERVER If the IP TYPE is STATIC this can be changed to point to a different DNS server Use the Temp buttons to move between letters and the Time button to choose letters I...