4
SAM SETUP 1
AUX:
AUX SENSOR
IP TYPE:
DHCP
IP:
192.168.100.0
MAC ADDR:
00:01:02:03:04:05
SUBNET MASK:
255.255.255.000
SERVER
STATUS:
CONNECTED
< BACK
NEXT >
SAM SETUP 2
DEFAULT GATEWAY:
192.168.001.001
DNS SERVER:
061.010.231.015
PORT:
49152
SERVER
STATUS:
CONNECTED
< BACK
NEXT >
AUX:
The auxiliary sensor can be renamed to something meaningful, such as WATER or GENERATOR. Use the Temp +/-- buttons to move
between letters, and the Time +/-- button to choose letters.
IP TYPE:
Choose DHCP (default) or STATIC for the Internet addressing type.
IP:
Shows the current IP address of the CAT--5 B--SAM. If IP TYPE is STATIC then this item can be changed. Use the Temp +/-- buttons to
move between letters, and the Time +/-- button to choose letters. If IP TYPE is DHCP, the IP address cannot change.
MAC ADDR:
Shows the MAC Address of the CAT--5 B--SAM’s network module.
SUBNET MASK:
If the IP TYPE is STATIC, this can be changed to a different subnet number. Use the Temp +/-- buttons to move between
letters, and the Time +/-- button to choose letters. If IP TYPE is DHCP, the SUBNET MASK cannot be changed.
DEFAULT GATEWAY:
If the IP TYPE is STATIC, this can be changed to point to a different gateway. Use the Temp +/-- buttons to move
between letters, and the Time +/-- button to choose letters. If IP TYPE is DHCP, the DEFAULT GATEWAY cannot be changed.
DNS SERVER:
If the IP TYPE is STATIC, this can be changed to point to a different DNS server. Use the Temp +/-- buttons to move
between letters, and the Time +/-- button to choose letters. If IP TYPE is DHCP, the DNS SERVER cannot be changed.
PORT:
This can be changed to use a different port through the homeowner’s network. The default is port 49152.
SERVER STATUS:
Shows status of the CAT--5 B--SAM connection to Bryant’s servers. If the screen shows NON CONNECTED, please
check network settings or network cable.
Home
Automation
Connection
(RS- 232)
STATUS
COMM1
COMM2
WLSC
WLS
A1
B1
C1
A2
B2
C2
SERIAL NUMBER
TEST
AUXILIARY
SENSOR
ABC TO
SYSTEM 1
ABC TO
SYSTEM 2
24VAC
Ethernet
Module
A06512
Fig. 1 -- CAT--5 Module Control Board
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
E
2012 Bryant Heating & Cooling Systems
D
7310 W. Morris St.
D
Indianapolis, IN 46231
Printed in U.S.A.
Edition Date: 02/12
Replaces: IIBBRCT--- 01
Catalog No. IIBBRCT---02
SYSTX
B
B
R
C
T01