background image

SYSTXBBRCT01

EVOLUTION

r

SYSTEM

CAT--5 (WIRED) BROADBAND

REMOTE ACCESS MODULE

Installation Instructions

NOTE

: Read the entire instruction manual before starting the

installation.

pointSET

t

U.S. Pat No. 7,415,102

TABLE OF CONTENTS

PAGE

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . . .

INSTALLATION CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . .

INTRODUCTION

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Computer Requirements

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

CAT--5 B--SAM INSTALLATION

2

. . . . . . . . . . . . . . . . . . . . . . .

BEFORE STARTING:

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Check Equipment and Job Site

2

. . . . . . . . . . . . . . . . . . . . . . . .

Component Location and Wiring Considerations

2

. . . . . . . . . .

Install Components

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Connect Evolution Systems

2

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Connect Auxiliary Sensor (optional)

2

. . . . . . . . . . . . . . . . . . . .

Connect Power Source and Network Cable

2

. . . . . . . . . . . . . . .

System Start--Up

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Network Setup

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

MAC Address and Serial Number

3

. . . . . . . . . . . . . . . . . . . . . .

Self--Test

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

RS--232 Connector

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Updating System Profile

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Local PC Access

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Account Setup

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TROUBLESHOOTING

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,
or use can cause explosion, fire, electrical shock, or other

conditions which may cause death, personal injury or property

damage. Consult a qualified installer, service agency or your
distributor or branch for information or assistance. The qualified

installer or agency must use factory--authorized kits or accessories
when modifying this product. Refer to the individual instructions

packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,
and work gloves. Have a fire extinguisher available. Read these

instructions thoroughly and follow all warnings and cautions
included in literature and attached to the unit. Consult local

building codes and the current edition of the National Electrical
Code (NEC) NFPA 70.

In Canada, refer to the current editions of the Canadian Electrical
Code CSA C22.1.

Recognize safety information. When you see this symbol

on

the unit and in instructions or manuals, be alert to the potential for
personal injury. Understand the signal words

DANGER

,

WARNING

, and

CAUTION

. These words are used with the

safety--alert symbol.

DANGER

identifies the most serious hazards,

which

will

result in severe personal injury or death.

WARNING

signifies hazards, which

could

result in personal injury or death.

CAUTION

is used to identify unsafe practices, which

may

result

in minor personal injury or product and property damage.

NOTE

is used to highlight suggestions which

will

result in enhanced

installation, reliability, or operation.

INSTALLATION CONSIDERATIONS

The CAT--5 Broadband Remote Access Module (CAT--5 B--SAM),
part number SYSTXBBRCT01, is powered with a 24VAC

transformer. A 120VAC supply must be near the mounting
location. Provisions must be made to secure the transformer to the

outlet.

The D--wire (24VAC) from the Evolution

t

System must

NOT be used to power the Remote Access Module.

This instruction covers the physical installation and start up of the

CAT--5 B--SAM. Use this instruction to guide the actual
installation process after the Evolution System(s) have been

installed. One CAT--5 B--SAM is capable of handling two
Evolution Systems.

INTRODUCTION

The CAT--5 B--SAM connects to a network router and allows
remote connectivity for up to two Evolution Systems within the

same building. The Evolution System owner as well as authorized

dealer can monitor and control the system via the Internet as well
as by telephone. The CAT--5 B--SAM communicates through the

homeowner’s cable or DSL Internet service. Broadband Internet
service with a network router is required. The CAT--5 B--SAM is

not compatible with dial--up Internet service. The CAT--5 B--SAM

can also monitor a dry--contact sensor to provide a warning for the
presence of water in the building, or some other use. If the sensor is

active, the Evolution System will not be disabled or shut down.

Computer Requirements

The CAT--5 B--SAM uses a web--based application to control and

monitor the Evolution System. This application will work with any

graphic user interface PC operating system (Microsoft, Apple,
Linux). The web--based application is optimized for use with

Microsoft’s Internet Explorer version 6 and above. Other web
browsers are compatible with some possible screen formatting

issues.

Содержание EVOLUTION CAT-B-SAM

Страница 1: ...fety alert symbol DANGER identifies the most serious hazards which will result in severe personal injury or death WARNING signifies hazards which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage NOTE is used to highlight suggestions which will result in enhanced installation reliability or...

Страница 2: ...iring of the ABC connector will cause the system to operate improperly Check to make sure all wiring is correct before proceeding with installation or turning on of power CAUTION Connect Evolution Systems Connect the A B and C wires from the Evolution System to terminals labeled A1 B1 and C1 Connect the second Evolution System if present to the terminals labeled A2 B2 and C2 ABC bus wiring only re...

Страница 3: ...curs The system can be forced to send its information through the following process if Internet and telephone access is required immediately Press and hold the Radio Test button for 15 seconds When the button is first pressed the Red LED will turn on Five seconds into the press the Yellow LED will turn on Fifteen seconds into the press the Green COM1 LED will turn on Release the button when the Gr...

Страница 4: ...GATEWAY If the IP TYPE is STATIC this can be changed to point to a different gateway Use the Temp buttons to move between letters and the Time button to choose letters If IP TYPE is DHCP the DEFAULT GATEWAY cannot be changed DNS SERVER If the IP TYPE is STATIC this can be changed to point to a different DNS server Use the Temp buttons to move between letters and the Time button to choose letters I...

Отзывы: