PERFORMANCE DATA

HVI Rated Energy Performance

MODEL

MODE

SUPPLY TEMP

NET AIR FLOW

POWER

CONSUMED

(WATTS)

SENSIBLE

RECOVERY

EFFICIENCY

APPARENT

SENSIBLE

EFFECTIVENESS

LATENT

RECOVERY

MOISTURE

TRANSFER

TOTAL

RECOVERY

EFFICIENCY

_

C

_

F

L/S

CFM

ERVBBSHB1100

Heating

0

32

21

45

42

68

79

0.63

0

32

27

58

46

68

76

0.58

0

32

41

87

70

63

71

0.48

---25

---13

22

47

58

55

78

0.60

Cooling

35

95

21

44

42

52

ERVBBSVB1100

Heating

0

32

21

45

42

68

79

0.63

0

32

27

58

46

68

76

0.58

0

32

41

87

70

63

71

0.48

---25

---13

22

47

58

55

78

0.60

Cooling

35

95

21

44

42

52

HRVBBSHB1100

Heating

0

32

18

39

37

66

78

0.03

0

32

24

50

44

65

74

0.01

0

32

40

85

68

59

68

0.01

---25

---13

23

48

56

57

84

0.03

Cooling

35

95

HRVBBSVB1100

Heating

0

32

18

39

37

66

78

0.03

0

32

24

50

44

65

74

0.01

0

32

40

85

68

59

68

0.01

---25

---13

23

48

56

57

84

0.03

Cooling

35

95

Ventilation Performance

MODEL

EXT. STATIC

PRESSURE

NET SUPPLY AIR FLOW

GROSS AIR FLOW

SUPPLY

EXHAUST

PA

IN WC

L/S

CFM

L/S

CFM

L/S

CFM

ERVBBSHB1100

25

0.1

55

116

56

119

55

116

50

0.2

53

113

54

115

53

112

100

0.4

50

105

51

108

50

105

200

0.8

42

89

43

92

41

87

250

1.0

38

80

39

83

37

78

ERVBBSVB1100

25

0.1

55

116

56

119

55

116

50

0.2

53

113

54

115

53

112

100

0.4

50

105

51

108

50

105

200

0.8

42

89

43

92

41

87

250

1.0

38

80

39

83

37

78

HRVBBSHB1100

25

0.1

52

110

53

112

57

121

50

0.2

50

106

51

108

54

115

100

0.4

46

97

47

100

50

106

200

0.8

37

79

38

81

42

90

250

1.0

33

70

34

72

37

79

HRVBBSVB1100

25

0.1

52

110

53

112

57

121

50

0.2

50

106

51

108

54

115

100

0.4

46

97

47

100

50

106

200

0.8

37

79

38

81

42

90

250

1.0

33

70

34

72

37

79

NOTE

: For additional data points, refer to HVI Directory at www.hvi.org

ER

V

/HR

V

Содержание ERVBBSVB

Страница 1: ...r stream A filter installed on the incoming outdoor air stream removes large airborne particles from the intake air stream before they enter the heat exchanger and reduces the maintenance required The...

Страница 2: ...for Energy and Heat Recovery Ventilators ERV Recommended w HRV or ERV Wall Control ERV Recommended HRV Recommended Honolulu Sacramento Salt Lake City Boise Salem Vancouver Helena Edmonton Calgary Regi...

Страница 3: ...eatures Basic Control Allows the user to manually set fan speed to low or high as required to maximize comfort Standard Control Offers automatic dehumidistat control and the option to select continuou...

Страница 4: ...times are in the standard mode as shipped Time between defrost when within specified temperature range Left Side View Front View Right Side View 1 2 3 4 A10126 Fig 3 ERVBBSHB and HRVBBSHB Unit Dimens...

Страница 5: ...ge 120 120 120 120 Max Power Watts 104 104 100 100 Max Amps 0 87 0 87 0 85 0 85 NOTE Drain Connector Kits are supplied with HRVs only They are not necessary with ERVs Ventilator Sizing Tables 1 and 2...

Страница 6: ...6 78 0 03 0 32 24 50 44 65 74 0 01 0 32 40 85 68 59 68 0 01 25 13 23 48 56 57 84 0 03 Cooling 35 95 Ventilation Performance MODEL EXT STATIC PRESSURE NET SUPPLY AIR FLOW GROSS AIR FLOW SUPPLY EXHAUST...

Страница 7: ...7 VENTILATOR INSTALLED WITH FORCED AIR SYSTEM A10105 VENTILATOR INSTALLED WITH INDEPENDENT AIR DISTRIBUTION A10106 ERV HRV...

Страница 8: ...hange at any time specifications or designs without notice and without incurring obligations E2010 Bryant Heating Cooling Systems D 7310 W Morris St D Indianapolis IN 46231 Printed in U S A Edition Da...

Отзывы: