background image

5

AIR DELIVERY -- CFM (BOTTOM RETURN WITH FILTER)

INPUT

BTUH

RETURN-AIR

SUPPLY

SPEED

EXTERNAL STATIC PRESSURE (IN. W.C.)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

40000

SIDE/BOTTOM

5(Gry)

1120

1080

1030

980

925

875

820

760

690

630

4(Yel)

880

845

810

780

740

710

680

640

615

570

3(Blu)

695

665

620

575

535

495

455

420

370

280

2(Org)

640

595

540

495

460

420

370

310

260

230

1(Red)

570

525

475

425

385

330

255

220

-

-

60000

SIDE/BOTTOM

5(Gry)

1720

1670

1620

1565

1505

1440

1375

1295

1220

1135

4(Yel)

1325

1285

1255

1220

1185

1145

1115

1075

1040

1000

3(Blu)

1010

970

925

875

835

785

745

690

660

620

2(Org)

1160

1115

1080

1045

1000

960

920

875

840

785

1(Red)

785

715

655

595

530

490

435

385

340

285

80000

SIDE/BOTTOM

5(Gry)

1810

1770

1720

1665

1610

1540

1475

1400

1315

1235

4(Yel)

1535

1500

1475

1435

1405

1370

1340

1310

1245

1160

3(Blu)

1380

1340

1305

1270

1240

1200

1165

1130

1090

1050

2(Org)

1180

1130

1095

1060

1015

975

935

895

850

800

1(Red)

1100

1045

1010

970

920

885

845

790

745

690

100000

SIDE/BOTTOM

5(Gry)

2040

1970

1885

1795

1720

1635

1540

1450

1360

1230

4(Yel)

1550

1505

1460

1415

1365

1325

1280

1230

1180

1135

3(Blu)

1780

1730

1690

1645

1610

1555

1481

1400

1310

1210

2(Org)

1345

1295

1250

1195

1155

1105

1055

1000

955

915

1(Red)

1390

1350

1295

1260

1200

1160

1105

1050

1010

965

120000

BOTTOM OR

TWO SIDES

5(Gry)

2275

2230

2185

2130

2055

1950

1825

1710

1610

1500

4(Yel)

1875

1820

1770

1720

1660

1600

1550

1505

1450

1390

3(Blu)

2170

2125

2075

2025

1975

1900

1790

1695

1590

1470

2(Org)

1475

1420

1350

1280

1215

1165

1105

1050

995

930

1(Red)

1625

1565

1505

1445

1385

1325

1275

1225

1170

1130

*A filter is required for each return---air inlet. Airflow performance included 3/4---in. (19 mm) washable filter media such as contained in factory---authorized

accessory filter rack. To determine airflow performance without this filter, assume an additional 0.1 in. W.C. available external static pressure.

--- Indicates unstable operating conditions.

Содержание 925SA Series

Страница 1: ...ntinuous fan speed from a compatible thermostat S External Media Filter Cabinet included S 4 way multipoise design for upflow downflow or horizontal installation with unique vent elbow and optional through the cabinet downflow venting capability S Multi tap ECM blower motor single speed inducer motor and single stage gas valve S Self diagnostics S Adjustable blower speed for cooling continuous fan...

Страница 2: ...1606UFR KGAWF1306UFR KGAWF1406UFR KGAWF1506UFR KGAWF1506UFR Electrical Data 030040 042060 048080 048100 066120 Input Voltage Volts Hertz Phase 115 60 1 Operating Voltage Range Min Max 104 127 Maximum Input Amps Amps 8 1 9 7 9 7 12 2 12 2 Unit Ampacity Amps 11 0 13 0 13 0 16 1 16 1 Minimum Wire Size AWG 14 14 14 12 12 Maximum Wire Length Minimum Wire Size Feet 33 28 28 35 35 M 10 1 8 5 8 5 10 7 10 ...

Страница 3: ... 66 2200 CFM 0 5 ESP 040 40 000 BTU 060 60 000 BTU 080 80 000 BTU 100 100 000 BTU 120 120 000 BTU Not all familes have these models A11165 FURNACE COMPONENTS RATING PLATE NOT SHOWN LOCATED ON BLOWER DOOR GAS VALVE MAIN LIMIT SWITCH BEHIND GAS VALVE REPRESENTATIVE DRAWING ONLY SOME MODELS MAY VARY IN APPEARANCE ELECTRICAL JUNCTION BOX IF REQUIRED LOCATION MAY VARY MEDIA CABINET OPERATING INSTRUCTIO...

Страница 4: ...mm LP KGAHA5750125 X X X X X Gas Orifice Kit 1 30mm LP KGAHA5750130 X X X X X Indoor Air Quality Bryant Perfect Air Purifier 16x25 406x635mm GAPAAXBB1625 A08 X X X X X Bryant Perfect Air Purifier 20x25 508x635mm GAPAAXBB2025 A08 X X X X X Bryant Perfect Air Purifier Repl Filter 16x25 406x635mm GAPABBCAR1625 A05 X X X X X Bryant Perfect Air Purifier Repl Filter 20x25 508x635mm GAPABBCAR1625 A05 X X...

Страница 5: ... 1090 1050 2 Org 1180 1130 1095 1060 1015 975 935 895 850 800 1 Red 1100 1045 1010 970 920 885 845 790 745 690 100000 SIDE BOTTOM 5 Gry 2040 1970 1885 1795 1720 1635 1540 1450 1360 1230 4 Yel 1550 1505 1460 1415 1365 1325 1280 1230 1180 1135 3 Blu 1780 1730 1690 1645 1610 1555 1481 1400 1310 1210 2 Org 1345 1295 1250 1195 1155 1105 1055 1000 955 915 1 Red 1390 1350 1295 1260 1200 1160 1105 1050 10...

Страница 6: ...202 61 6 224 68 3 100 000 NA 17 5 2 94 28 7 205 62 5 229 69 8 120 000 NA NA NA 83 25 3 217 66 1 NOTE See notes at end of venting tables See Table 3 for altitudes over 4500 ft 1370 M Not all families have these models Table 2 Deductions from Maximum Equivalent Vent Length Ft M Pipe Diameter in 1 1 2 2 2 1 2 3 4 Mitered 90º Elbow 8 2 4 8 2 4 8 2 4 NA NA NA NA Medium Radius 90º Elbow 5 1 5 5 1 5 5 1 ...

Страница 7: ...3 0 121 36 9 130 39 6 NA NA 60 000 7 2 1 82 25 0 152 46 3 168 51 2 NA 80 000 NA 35 10 7 111 33 8 148 45 1 156 47 5 100 000 NA NA 67 20 4 157 47 9 170 51 8 120 000 NA NA NA 56 17 1 164 50 0 9001 to 10 000 2743 to 3048 40 000 5 1 5 110 33 5 115 35 1 NA NA 60 000 NA 76 23 2 142 43 3 156 47 5 NA 80 000 NA 31 9 4 103 31 4 137 41 8 142 43 3 100 000 NA NA 62 18 9 147 44 8 157 47 9 120 000 NA NA NA 51 15 ...

Страница 8: ... 9 1 22 9 19 5 15 5 N A 80000 20 10 Ft 20 70 78 70 60 20 70 175 183 154 20 70 175 215 181 M 6 1 21 3 23 8 21 3 18 3 6 1 21 3 53 3 55 8 46 9 6 1 21 3 53 3 65 5 55 2 0 20 Ft 20 42 41 33 21 20 70 132 111 89 20 70 157 133 107 M 6 1 12 8 12 5 10 1 6 4 6 1 21 3 40 2 33 8 27 1 6 1 21 3 47 9 40 5 32 6 20 30 Ft 20 25 23 14 1 20 70 94 77 57 20 70 113 94 71 M 6 1 7 6 7 0 4 3 0 3 6 1 21 3 28 7 23 5 17 4 6 1 2...

Страница 9: ...f heat exchangers motors and controls 60 80 27 C 16 C SUPPLY AIR A10490 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS POSITION CLEARANCE Rear 0 0 mm Front Combustion air openings in furnace and in structure 1 in 25 mm Required for service 24 in 610 mm All Sides of Supply Plenum 1 in 25 mm Sides 0 0 mm Vent 0 0 mm Top of Furnace 1 in 25 mm Recommended COMBUSTION AIR PIPE FOR NON DIRECT 1 PIPE VENT AP...

Страница 10: ...sed Coil Assembly or Coil Box 22 1 8 562 0 19 482 6 23 3 4 603 3 20 3 8 517 5 1 The plenum should be constructed 1 4 in 6 mm smaller in width and depth than the plenum dimensions shown above Concentric Vent Kit A93086 A concentric vent kit allows vent and combustion air pipes to terminate through a single exit in a roof or side wall One pipe runs inside the other allowing venting through the inner...

Страница 11: ... 115 V FIELD SUPPLIED DISCONNECT AUXILIARY J BOX 24 V TERMINAL BLOCK THREE WIRE HEATING ONLY FIVE WIRE NOTE 1 NOTE 2 FIELD SUPPLIED DISCONNECT CONDENSING UNIT TWO WIRE FURNACE C O N T R O L R G COM W C R G Y GND GND FIELD 24 V WIRING FIELD 115 208 230 460 V WIRING FACTORY 24 V WIRING FACTORY 115 V WIRING 208 230 OR 460 V THREE PHASE 208 230 V SINGLE PHASE BLOWER DOOR SWITCH WHT BLK WHT BLK NOTES C...

Страница 12: ...gle c For 1600 CFM 22 in 559 mm round or 14 1 2 x 22 1 16 in 368 x 560mm rectangle d For airflow requirements above 1800 CFM see Air Delivery table in Installation Instructions literature for specific use of single side inlets The use of both side inlets a combina tion of 1 side and the bottom or the bottom only return air openings may be required for airflow requirements above 1800 CFM at 0 5 in ...

Страница 13: ...n accessory highly efficient Media Filter is available as an option _____________ Media Filter Casing Casing shall be of 030 in thickness minimum pre painted galvanized steel Draft Inducer Motor Draft inducer motor shall be single speed design Primary Heat Exchangers Primary heat exchangers shall be 3 Pass corrosion resistant aluminized steel of fold and crimp sectional design and applied operatin...

Страница 14: ...e or change at any time specifications or designs without notice and without incurring obligations E2011 Bryant Heating Cooling Systems D 7310 W Morris St D Indianapolis IN 46231 Printed in U S A Edition Date 09 11 Replaces NEW Catalog No PDS925SA 01 ...