SAFETY PRECAUTIONS

PERSONAL INJURY, DEATH, OR PROPERTY

DAMAGE HAZARD

Failure to follow this warning could result in personal injury,

death, or property damage.
Read and follow all instructions and warnings, including

labels shipped with or attached to unit before operating your

new air conditioner.

!

WARNING

Any time you see this symbol 

 in manuals, instructions and on

the unit, be aware of the potential for personal injury. There are

three levels of precaution:

DANGER 

identifies the most serious hazards which will result in

severe personal injury or death.

WARNING

 signifies hazards that could result in personal injury or

death.

CAUTION

 is used to identify unsafe practices which would result

in minor personal injury or product and property damage.

NOTE 

is used to highlight suggestions which 

will

 result in

enhanced installation, reliability, or operation.

PERSONAL INJURY, DEATH AND / OR PROPERTY

DAMAGE HAZARD

Failure to follow this warning could result in personal injury,

death or property damage.
Improper installation, adjustment, alteration, service,

maintenance, or use can cause explosion, fire, electrical shock,

or other conditions which may cause personal injury or

property damage.
Consult a qualified installer, service agency, your distributor

or branch for information or assistance.  The qualified installer

or service agency must use factory

authorized kits or

accessories when modifying this product.

!

WARNING

GENERAL

The high wall fan coil unit provides quiet, maximum comfort.  In

addition to cooling and/or heating, the high wall fan coil unit

matched with an outdoor condensing unit will filter and

dehumidify the air in the room to provide maximum comfort.

IMPORTANT

: The high wall fan coil unit should be installed by

authorized personnel only; using approved tubing and accessories.
If technical assistance, service or repair is needed, contact  the
installer.
The high wall fan coil unit can be set up and operated from the

remote control (provided). 

If the remote is misplaced, the system

can be operated from the “Auto” setting on the unit.

Operating Modes:

The high wall fan coil unit has five operating modes.

S

Fan only

S

Auto

S

Heating

S

Cooling

S

Dehumidification (DRY)

Fan Only

In Fan Only mode, the system filters and circulates room air

without changing room air temperature.

Auto

In Auto mode, the system will automatically cool or heat the room

according to the user

selected set point.

Heating

In Heating mode, the system heats and filters room air.

Cooling

In Cooling mode, the system cools, dries and filters room air.

Dehumidification (DRY)

In Dehumidification mode, the system dries, filters and slightly

cools room air temperature. Use of this mode 

does not

 take the

place of a dehumidifier.

Remote Control

The remote control transmits commands to set up and operate the

system. The control has a window display panel that shows the

current system status. The control can be secured to a surface when

used with the mounting bracket provided.

Wired Remote Control (Optional)

Содержание 619KB

Страница 1: ...our new equipment in the spaces provided This information along with the installation data and dealer contact information will be helpful should your system require maintenance or service UNIT INFORMA...

Страница 2: ...fying this product WARNING GENERAL The high wall fan coil unit provides quiet maximum comfort In addition to cooling and or heating the high wall fan coil unit matched with an outdoor condensing unit...

Страница 3: ...cator power indicator receiver window drying indicator display remote controller air inlet panel filter aux button horizontal louver air outlet Fig 1 Indoor Outdoor Unit DISPLAY PANELS NOTE The displa...

Страница 4: ...over Send signal Turbo mode 8 46 heating function Set temperature Set time X FAN function TIMER ON TIMER OFF Child lock Up down swing Left right swing Set fan speed Light Temp display type Set temp Ou...

Страница 5: ...about 6 months 4 Replace the batteries when there is no audible beep from the indoor unit or if the Transmission Indicator fails to light Remote Control Operation Quick Start NOTE When transmitting a...

Страница 6: ...own OFF 1 0 2 3 4 5 1 Fig 8 Swing buttons Press the Left Right Swing Louver button to select five different horizontal air discharge directions including Continuous Sweep The Horizontal Swing Louver i...

Страница 7: ...to user individuation sleep setting status but do not change the temperature press Turbo button directly for confirmation NOTE In the above presetting or enquiry procedure if continuously within 10s t...

Страница 8: ...on may result in equipment damage When cleaning the front panel do not use water hotter than 105_F 40 56_C and do not pour water onto the fan coil Do not use abrasive or petroleum based cleaners as th...

Страница 9: ...ert plug Restart unit Water leaks into room from Indoor unit Condensing water has overflowed Check indoor condensing drain or call your representative Unit System Does Not Work To protect the unit upo...

Страница 10: ...tinue or change at any time specifications or designs without notice and without incurring obligations E2016 Bryant Heating Cooling Systems D 7310 W Morris St D Indianapolis IN 46231 Edition Date 03 1...

Отзывы: