31
ACCESSORY DIMENSIONS — 580F (cont)
CONNECTOR
PKG. ACCY.
B
C
D ALT
DRAIN
HOLE
GAS
POWER
CONTROL
ACCESSORY
POWER
CRBTMPWR001A01
2
′
-8
7
/
16
″
[827]
1
′
-10
15
/
16
″
[583]
1
3
/
4
″
[44.5]
3
/
4
″
[19] NPT
3
/
4
″
[19] NPT
1
/
2
″
[12.7] NPT
1
/
2
″
[12.7] NPT
CRBTMPWR002A01
1
1
/
4
″
[31.7]
CRBTMPWR003A01
1
/
2
″
[12.7] NPT
3
/
4
″
[19] NPT
CRBTMPWR004A01
3
/
4
″
[19] NPT
1
1
/
4
″
[31.7]
NOTES:
1. Roof curb accessory is shipped disassembled.
2. Insulated panels: 1-in. thick polyurethane foam,
1
3
/
4
lb density.
3. Dimensions in [
] are in millimeters.
4. Roof curb: 16-gage steel.
5. Attach ductwork to curb (flanges of duct rest on
curb).
6. Service clearance 4 ft on each side.
7.
Direction of airflow.
8. Connector packages CRBTMPWR001A01 and
2A01 are for thru-the-curb gas type. Packages
CRBTMPWR003A01 and 4A01 are for thru-the-
bottom type gas connections.
ROOF CURB
ACCESSORY
“A”
UNIT SIZE
CRRFCURB003A01
1
′
-2
″
[356]
580F
090-151
CRRFCURB004A01
2
′
-0
″
[610]
Roof Curb Details
a48-7321
58
0
F
03
6-
15
1
Содержание 579F180
Страница 26: ...26 BASE UNIT DIMENSIONS 580F036 072 a48 8195 580F036 151 ...
Страница 27: ...27 BASE UNIT DIMENSIONS 580F073 a48 8196 580F036 151 ...
Страница 28: ...28 BASE UNIT DIMENSIONS 580F090 120 150 a48 8197 580F036 151 ...
Страница 29: ...29 BASE UNIT DIMENSIONS 580F091 103 121 151 a48 8198 580F036 151 ...
Страница 87: ...87 BASE UNIT DIMENSIONS 581B036 072 a48 8199 581B036 150 ...
Страница 89: ...89 ACCESSORY DIMENSIONS 581B036 072 a48 8201 581B036 150 ...
Страница 90: ...90 ACCESSORY DIMENSIONS 581B090 150 a48 8202 581B036 150 ...
Страница 135: ...135 TYPICAL WIRING SCHEMATICS 581B SIZES 036 150 581B090 460 3 60 Shown a48 8233 581B036 150 ...
Страница 167: ...167 TYPICAL WIRING SCHEMATICS 579F 579F240 208 230 V Shown a48 7929 0TFQ004 012 579F180 300 ...
Страница 174: ...174 BASE UNIT DIMENSIONS 580F180 210 a48 8203 0TFQ004 012 580F180 300 ...
Страница 175: ...175 BASE UNIT DIMENSIONS 580F240 a48 8204 0TFQ004 012 580F180 300 ...
Страница 176: ...176 BASE UNIT DIMENSIONS 580F300 a48 8205 0TFQ004 012 580F180 300 ...
Страница 178: ...178 ACCESSORY DIMENSIONS 580F300 Vertical Roof Curbs 580F300 a48 7456 0TFQ004 012 580F180 300 ...
Страница 196: ...196 TYPICAL PIPING AND WIRING 580F180 300 LEGEND NEC National Electrical Code b48 1258 0TFQ004 012 580F180 300 ...
Страница 202: ...202 BASE UNIT DIMENSIONS 581A210 300 a48 8206 581A155 300 ...
Страница 206: ...206 ACCESSORY DIMENSIONS 581A210 300 a48 8234 581A155 300 ...
Страница 249: ...249 TYPICAL PIPING AND WIRING 581A 581A155 Shown LEGEND NEC National Electrical Code b48 1258 581A155 300 ...